The influence of the magnetic field on the performance of an active magnetic regenerator (AMR)

被引:26
作者
Bjork, R. [1 ]
Engelbrecht, K. [1 ]
机构
[1] DTU, Fuel Cells & Solid State Chem Div, Riso Natl Lab Sustainable Energy, DK-4000 Roskilde, Denmark
来源
INTERNATIONAL JOURNAL OF REFRIGERATION-REVUE INTERNATIONALE DU FROID | 2011年 / 34卷 / 01期
关键词
Magnetic refrigerator; Magnetic field; Simulation; Modelling; Performance Variation; REFRIGERATION;
D O I
10.1016/j.ijrefrig.2010.07.004
中图分类号
O414.1 [热力学];
学科分类号
摘要
The influence of the time variation of the magnetic field, termed the magnetic field profile, on the performance of a magnetocaloric refrigeration device using the active magnetic regeneration (AMR) cycle is studied for a number of process parameters for both a parallel plate and packed bed regenerator using a numerical model. The cooling curve of the AMR is shown to be almost linear far from the Curie temperature of the magnetocaloric material. It is shown that a magnetic field profile that is 10% of the cycle time out of sync with the flow profile leads to a drop in both the maximum temperature span and the maximum cooling capacity of 20-40% for both parallel plate and packed bed regenerators. The maximum cooling capacity is shown to depend very weakly on the ramp rate of the magnetic field. Reducing the temporal width of the high field portion of the magnetic field profile by 10% leads to a drop in maximum temperature span and maximum cooling capacity of 5-20%. An increase of the magnetic field from 1 T to 1.5 T increases the maximum cooling capacity by 30-50% but the maximum temperature span by only 20-30%. Finally, it was seen that the influence of changing the magnetic field was more or less the same for the different regenerator geometries and operating parameters studied here. This means that the design of the magnet can be done independently of the regenerator geometry. (C) 2010 Elsevier Ltd and IIR. All rights reserved.
引用
收藏
页码:192 / 203
页数:12
相关论文
共 30 条
[1]   Numerical modeling for active magnetic regenerative refrigeration [J].
Allab, F ;
Kedous-Lebouc, A ;
Fournier, JM ;
Yonnet, JP .
IEEE TRANSACTIONS ON MAGNETICS, 2005, 41 (10) :3757-3759
[2]  
[Anonymous], 2009, P 3 INT C MAGN REFR
[3]  
[Anonymous], ADV CRYOGEN ENG
[4]  
[Anonymous], 83 NASA STIRECON
[5]  
[Anonymous], P 3 INT C MAGN REFR
[6]  
[Anonymous], PHYS PRICIPLES MAGNE
[7]   A versatile magnetic refrigeration test device [J].
Bahl, C. R. H. ;
Petersen, T. F. ;
Pryds, N. ;
Smith, A. .
REVIEW OF SCIENTIFIC INSTRUMENTS, 2008, 79 (09)
[8]   Review and comparison of magnet designs for magnetic refrigeration [J].
Bjork, R. ;
Bahl, C. R. H. ;
Smith, A. ;
Pryds, N. .
INTERNATIONAL JOURNAL OF REFRIGERATION-REVUE INTERNATIONALE DU FROID, 2010, 33 (03) :437-448
[9]  
BJORK R, J MAGN MAGN IN PRESS
[10]   Magnetic phase transitions and the magnetothermal properties of gadolinium [J].
Dan'kov, SY ;
Tishin, AM ;
Pecharsky, VK ;
Gschneidner, KA .
PHYSICAL REVIEW B, 1998, 57 (06) :3478-3490