An Interleaved Converter for 12-pulse Rectifier Harmonic Suppression

被引:3
|
作者
Li, Yuan [1 ]
Yang, Wei [1 ]
Cang, Sheng [1 ]
Yang, Shiyan [1 ]
机构
[1] Harbin Inst Technol, Sch Elect Engn & Automat, Harbin, Heilongjiang, Peoples R China
关键词
12-pulse rectifier; AIPR; Interleaved APFC; THD; INTERPHASE TRANSFORMER; DIODE RECTIFIER; INPUT; POWER; SYSTEM; OUTPUT;
D O I
10.6113/JPE.2017.17.5.1349
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
In order to further improve the harmonic suppression capability of conventional 12-pulse rectifiers, this paper proposes a low harmonic 12-pulse rectifier using an Active Inter-Phase Reactor (AIPR). Through a detailed analysis of the relationship between the input current, output current and circulating current of the DC side, the mechanism where the AC grid side current harmonics can be suppressed by the DC side circulating current is revealed. On this basis, an interleaved APFC controlled by a DSP is designed and used as an AIPR along with an interphase reactor. A simulation is carried out with MATLAB/Simulink and an experiment is performed on a 9-kVA prototype. The obtained results verify the feasibility and validity of the proposed approach. Compared with a traditional 12-pulse rectifier, the THD can be reduced to 1/5 of the original value, and the capacity of the AIPR is only 2% of the load power. Thus, it is suitable for high-power applications.
引用
收藏
页码:1349 / 1362
页数:14
相关论文
共 50 条
  • [1] Active harmonic suppression of paralleled 12-pulse rectifier at DC side
    MENG FanGangYANG Wei YANG SHiYan School of Information and Electrical EngineeringHarbin Institute of Technology at WeiHaiWeiHai China School of Electrical Engineering and AutomationHarbin Institute of TechnologyHarbin China
    Science China(Technological Sciences), 2011, 54 (12) : 3320 - 3331
  • [2] Active harmonic suppression of paralleled 12-pulse rectifier at DC side
    Meng FanGang
    Yang Wei
    Yang SHiYan
    SCIENCE CHINA-TECHNOLOGICAL SCIENCES, 2011, 54 (12) : 3320 - 3331
  • [3] Active harmonic suppression of paralleled 12-pulse rectifier at DC side
    FanGang Meng
    Wei Yang
    SHiYan Yang
    Science China Technological Sciences, 2011, 54 : 3320 - 3331
  • [4] Active harmonic suppression of paralleled 12-pulse rectifier at DC side
    MENG FanGang1
    2 School of Electrical Engineering and Automation
    Science China(Technological Sciences), 2011, (12) : 3320 - 3331
  • [5] Hybrid Harmonic Suppression at DC Side for Parallel-Connected 12-Pulse Rectifier
    Chen, Tao
    Chen, Xiaoqiang
    Wang, Ying
    JOURNAL OF ELECTRICAL ENGINEERING & TECHNOLOGY, 2023, 18 (03) : 2043 - 2060
  • [6] Hybrid Harmonic Suppression at DC Side for Parallel-Connected 12-Pulse Rectifier
    Tao Chen
    Xiaoqiang Chen
    Ying Wang
    Journal of Electrical Engineering & Technology, 2023, 18 : 2043 - 2060
  • [7] Low harmonic 12-pulse rectifier with a circulating current shaping circuit
    Wang, Jingfang
    Yao, Xuliang
    Guan, Qi
    Deng, Changji
    Yang, Shiyan
    TURKISH JOURNAL OF ELECTRICAL ENGINEERING AND COMPUTER SCIENCES, 2020, 28 (03) : 1355 - 1370
  • [8] Effect of harmonic voltages on DC-output voltage of 12-pulse rectifier
    Yoshii T.
    IEEJ Transactions on Industry Applications, 2018, 138 (02) : 99 - 104
  • [9] Harmonic Reduction for 12-Pulse Four Star Thyristor Rectifier with Active Auxiliary Circuit
    Wang, Jingfang
    Yang, Shiyan
    Yang, Wei
    2015 IEEE 11TH INTERNATIONAL CONFERENCE ON POWER ELECTRONICS AND DRIVE SYSTEMS (PEDS 2015), 2015, : 301 - 306
  • [10] The Research on Fuzzy Control of 12-Pulse Rectifier
    Lan Hai
    Gao Junhu
    Meng Jie
    Lin Ting
    Li Jun
    2012 ASIA-PACIFIC POWER AND ENERGY ENGINEERING CONFERENCE (APPEEC), 2012,