Development of a millimetre wave based SAR real-time imaging system for three-dimensional non-destructive testing

被引:0
|
作者
Schwaebig, Christopher [1 ]
Wang, Siying [1 ]
Guetgemann, Sabine [1 ]
机构
[1] Fraunhofer Inst High Frequency Phys & Radar Tech, Dept Integrated Circuits & Sensor Syst, Fraunhoferstr 20, D-53343 Wachtberg, Germany
关键词
Millimetre waves; FMCW radar; SAR; real-time imaging; three-dimensional imaging; non-destructive testing;
D O I
10.1515/teme-2021-0029
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
The following article describes the development of a millimetre wave based real-time imaging system for three dimensional non-destructive testing of goods. For this purpose a rotating antenna is used which is fed from an FMCW radar. The received measuring data is processed with a SAR algorithm. Due to the fact that a reflexive measurement method is used, the integration of the system into existing systems is simplified. To make the computing power-intensive SAR image processing possible, the complete signal processing chain of the image processing is executed on the graphics card. The article elucidates the concept for calculating the measurement parameters which have to be elaborated for the implementation of the image processing of the whole system.
引用
收藏
页码:488 / 497
页数:10
相关论文
共 50 条
  • [21] Non-Destructive Measurement of Three-Dimensional Plants Based on Point Cloud
    Wang, Yawei
    Chen, Yifei
    PLANTS-BASEL, 2020, 9 (05):
  • [22] Non-destructive testing of arbitrarily shaped refractive objects with millimetre-wave synthetic aperture radar imaging
    Ullmann, Ingrid
    Adametz, Julian
    Oppelt, Daniel
    Benedikter, Andreas
    Vossiek, Martin
    JOURNAL OF SENSORS AND SENSOR SYSTEMS, 2018, 7 (01) : 309 - 317
  • [23] Real-time three-dimensional electrical impedance imaging
    Blue, RS
    Isaacson, D
    Newell, JC
    PHYSIOLOGICAL MEASUREMENT, 2000, 21 (01) : 15 - 26
  • [24] Real-time three-dimensional imaging of macroscopic structures
    Wilson, T
    Neil, MAA
    Juskaitis, R
    JOURNAL OF MICROSCOPY-OXFORD, 1998, 191 : 116 - 118
  • [25] Development of a High-Sensitivity Millimeter-Wave Radar Imaging System for Non-Destructive Testing
    Murakami, Hironaru
    Fukuda, Taiga
    Otera, Hiroshi
    Kamo, Hiroyuki
    Miyoshi, Akito
    SENSORS, 2024, 24 (15)
  • [26] Scheme of Real-time Dammann grating based miniaturized three-dimensional endoscopic imaging system
    Wang, Xiaoxin
    Zhou, Changhe
    Dai, Enwen
    HOLOGRAPHY AND DIFFRACTIVE OPTICS III, 2008, 6832
  • [27] Photoacoustic tomography system for noninvasive real-time three-dimensional imaging of epilepsy
    Wang, Bo
    Xiang, Liangzhong
    Jiang, Max S.
    Yang, Jianjun
    Zhang, Qizhi
    Carney, Paul R.
    Jiang, Huabei
    BIOMEDICAL OPTICS EXPRESS, 2012, 3 (06): : 1427 - 1432
  • [28] Real-time three-dimensional optoacoustic imaging using an acoustic lens system
    Niederhauser, JJ
    Jaeger, M
    Frenz, M
    APPLIED PHYSICS LETTERS, 2004, 85 (05) : 846 - 848
  • [29] A Novel Thermosonic Imaging System for Non-destructive Testing
    Willey, C. L.
    Xiang, D.
    Long, M.
    43RD REVIEW OF PROGRESS IN QUANTITATIVE NONDESTRUCTIVE EVALUATION, 2017, 1806
  • [30] MILLIMETER WAVE RADIOMETERS FOR APPLICATIONS IN IMAGING AND NON-DESTRUCTIVE TESTING
    Viegas, Colin
    Alderman, Byron
    Powell, Jeff
    Liu, Hairui
    Wang, Hui
    Sloan, Robin
    2015 8TH UK, EUROPE, CHINA MILLIMETER WAVES AND THZ TECHNOLOGY WORKSHOP (UCMMT), 2015,