Laser-scribed Graphene Electrodes Functionalized with Nafion/Fe3O4 Nanohybrids for the Ultrasensitive Detection of Neurotoxin Drug Clioquinol

被引:22
作者
Madhuvilakku, Rajesh [1 ,2 ]
Yen, Yi-Kuang [1 ]
Yan, Wei-Mon [2 ]
Huang, Guang-Wei [1 ]
机构
[1] Natl Taipei Univ Technol, Dept Mech Engn, Taipei 106, Taiwan
[2] Natl Taipei Univ Technol, Dept Energy & Refrigerat Air Conditioning Engn, Taipei 106, Taiwan
关键词
CARBON NANOTUBES; SPECTROPHOTOMETRIC DETERMINATION; SELECTIVE DETECTION; GLUCOSE BIOSENSORS; FABRICATION; SENSOR; CONDUCTIVITY; TEMPERATURE; DEPOSITION; MEMBRANES;
D O I
10.1021/acsomega.2c01069
中图分类号
O6 [化学];
学科分类号
0703 ;
摘要
The analysis of pharmaceutical active ingredients plays an important role in quality control and clinical trials because they have a significant physiological effect on the human body even at low concentrations. Herein, a flexible three-electrode system using laser-scribed graphene (LSG) technology, which consists of Nafion/Fe3O4 nanohybrids immobilized on LSG as the working electrode and LSG counter and reference electrodes on a single polyimide film, is presented. A Nafion/Fe3O4/LSG electrode is constructed by drop coating a solution of Nafion/Fe3O4, which is electrostatically self-assembled between positively charged Fe3O4 and negatively charged Nafion on the LSG electrode and is used for the first time to determine a neurotoxicity drug (clioquinol; CQL) in biological samples. Owing to their porous 3D structure, an enriched surface area at the active edges and polar groups (OH, COOH, and -SO3H) in Nafion/Fe3O4/LSG electrodes resulted in excellent wettability to facilitate electrolyte diffusion, which gave similar to twofold enhancement in electrocatalytic activity over LSG electrodes. The experimental parameters affecting the analytical performance were investigated. The quantification of clioquinol on the Nafion/Fe3O4/LSG electrode surface was examined using differential pulse voltammetry and chronoamperometry techniques. The fabricated sensor displays preferable sensitivity (17.4 mu A mu M-1 cm(-2)), a wide linear range (1 nM to 100 mu M), a very low detection limit (0.73 nM), and acceptable selectivity toward quantitative analysis of CQL. Furthermore, the reliability of the sensor was checked by CQL detection in spiked human blood serum and urine samples, and satisfactory recoveries were obtained.
引用
收藏
页码:15936 / 15950
页数:15
相关论文
共 80 条
[1]   Deposition of nanomaterials: A crucial step in biosensor fabrication [J].
Ahmad, Rafiq ;
Wolfbeis, Otto S. ;
Hahn, Yoon-Bong ;
Alshareef, Husam N. ;
Torsi, Luisa ;
Salama, Khaled N. .
MATERIALS TODAY COMMUNICATIONS, 2018, 17 :289-321
[2]   A temperature-compensated graphene sensor for nitrate monitoring in real-time application [J].
Alahi, Md Eshrat E. ;
Nag, Anindya ;
Mukhopadhyay, Subhas Chandra ;
Burkitt, Lucy .
SENSORS AND ACTUATORS A-PHYSICAL, 2018, 269 :79-90
[3]   Facile fabrication of a novel 3D rose like lanthanum doped zirconia decorated reduced graphene oxide nanosheets: An efficient electro-catalyst for electrochemical reduction of futuristic anti-cancer drug salinomycin during pharmacokinetic study [J].
Alkahtani, Saad A. ;
Mahmoud, Ashraf M. ;
Mahnashi, Mater H. ;
Ali, Ramadan ;
El-Wekil, Mohamed M. .
BIOSENSORS & BIOELECTRONICS, 2020, 150
[4]   MAGNETITE FE3O4(111) - SURFACE-STRUCTURE BY LEED CRYSTALLOGRAPHY AND ENERGETICS [J].
BARBIERI, A ;
WEISS, W ;
VANHOVE, MA ;
SOMORJAI, GA .
SURFACE SCIENCE, 1994, 302 (03) :259-279
[5]   One-step electrosynthesized molecularly imprinted polymer on laser scribed graphene bisphenol a sensor [J].
Beduk, Tutku ;
Lahcen, Abdellatif Ait ;
Tashkandi, Nouran ;
Salama, Khaled Nabil .
SENSORS AND ACTUATORS B-CHEMICAL, 2020, 314
[6]   SPECTROPHOTOMETRIC DETERMINATION OF HALOGENATED 8-HYDROXYQUINOLINE DERIVATIVES [J].
BELAL, F .
TALANTA, 1984, 31 (08) :648-650
[7]   Nanocomposite membranes of Nafion and Fe3O4-anchored and Nafion-functionalized multiwalled carbon nanotubes exhibiting high proton conductivity and low methanol permeability for direct methanol fuel cells [J].
Chang, Chia-Ming ;
Li, Hsieh-Yu ;
Lai, Juin-Yih ;
Liu, Ying-Ling .
RSC ADVANCES, 2013, 3 (31) :12895-12904
[8]   Electrochemical aptasensor for 17β-estradiol using disposable laser scribed graphene electrodes [J].
Chang, Zhu ;
Zhu, Bicheng ;
Liu, JinJin ;
Zhu, Xu ;
Xu, Maotian ;
Travas-Sejdic, Jadranka .
BIOSENSORS & BIOELECTRONICS, 2021, 185
[9]   Flow-injection amperometric glucose biosensors based on graphene/Nafion hybrid electrodes [J].
Choi, Bong Gill ;
Im, Jinkyu ;
Kim, Hoon Sik ;
Park, HoSeok .
ELECTROCHIMICA ACTA, 2011, 56 (27) :9721-9726
[10]   ASSAY FOR IODOCHLORHYDROXYQUIN IN IODOCHLORHYDROXYQUIN OINTMENT [J].
COHEN, J ;
KLUCHESKY, E .
JOURNAL OF PHARMACEUTICAL SCIENCES, 1963, 52 (07) :693-+