Fault-Tolerant Control of a Wind Turbine Generator Based on Fuzzy Logic and Using Ensemble Learning

被引:4
|
作者
Cusido, Jordi [1 ,2 ]
Lopez, Arnau [2 ]
Beretta, Mattia [1 ,2 ]
机构
[1] SMARTIVE, Ps Almogavers 44, Sabadell 08204, Spain
[2] Univ Politecn Catalunya UPC, Unitat Transversal Gestio Ambit Camins UTGAC, Barcelona 08034, Spain
关键词
FAST; wind turbine; fault-tolerant control; power derating; fuzzy logic; PITCH CONTROL; ACTUATOR; SATURATION; DESIGN;
D O I
10.3390/en14165167
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
Wind energy is a form of renewable energy with the highest installed capacity. However, it is necessary to reduce the operation and maintenance costs and extend the lifetime of wind turbines to make wind energy more competitive. This paper presents a power-derating-based Fault-Tolerant Control (FTC) model in 2 MW three-bladed wind turbines implemented using the National Renewable Energy Laboratory's (NREL) Fatigue, Aerodynamics, Structures, and Turbulence (FAST) wind turbine simulator. This control strategy is potentially supported by the health status of the gearbox, which was predicted by means of algorithms and quantified in an indicator denominated as a merge developed by SMARTIVE, a pioneering of in this idea. Fuzzy logic was employed in order to decide whether to down-regulate the output power or not, and to which level to adjust to the needs of the turbines. Simulation results demonstrated that a reduction in the power output resulted in a safer operation, since the stresses withstood by the blades and tower significantly decreased. Moreover, the results supported empirically that a diminution in the generator torque and speed was acheived, resulting in a drop in the gearbox bearing and oil temperatures. By implementing this power-derating FTC, the downtime due to failure stops could be controlled, and thus the power production noticeably grew. It has been estimated that more than 325,000 tons of CO2 could be avoided yearly if implemented globally.
引用
收藏
页数:20
相关论文
共 50 条
  • [21] Fault-tolerant wind turbine pitch control using adaptive sliding mode estimation
    Lan, Jianglin
    Patton, Ron J.
    Zhu, Xiaoyuan
    RENEWABLE ENERGY, 2018, 116 : 219 - 231
  • [22] Integrated design of fault-tolerant control for flight control systems using observer and fuzzy logic
    Unal, Gulay
    AIRCRAFT ENGINEERING AND AEROSPACE TECHNOLOGY, 2021, 93 (04) : 723 - 732
  • [23] Fault-tolerant Control of Wound Rotor Synchronous Generator in Wind Turbines
    Lesic, Vinko
    Vasak, Mario
    Stojcic, Goran
    Wolbank, Thomas M.
    2014 INTERNATIONAL CONFERENCE ON ELECTRICAL MACHINES (ICEM), 2014, : 1758 - 1764
  • [24] Fault-tolerant control of a PMSG-based wind turbine based on parallel interleaved converters
    Abbes, Mohamed
    TURKISH JOURNAL OF ELECTRICAL ENGINEERING AND COMPUTER SCIENCES, 2019, 27 (04) : 3219 - 3233
  • [25] Stable fault-tolerant adaptive fuzzy/neural control for a turbine engine
    Diao, YX
    Passino, KM
    IEEE TRANSACTIONS ON CONTROL SYSTEMS TECHNOLOGY, 2001, 9 (03) : 494 - 509
  • [26] Fault-Tolerant Control of Floating Wind Turbine With Switched Adaptive Sliding Mode Controller
    Song, Ziqiu
    Liu, Jizhen
    Liu, Yajuan
    Hu, Yang
    Fang, Fang
    IEEE TRANSACTIONS ON AUTOMATION SCIENCE AND ENGINEERING, 2024, 21 (03) : 3705 - 3718
  • [27] Fault-tolerant control method of fuzzy logic system based on decision tree algorithm
    Zhao W.
    Gao F.
    International Journal of Applied Systemic Studies, 2023, 10 (02) : 94 - 110
  • [28] Fault-tolerant optimal pitch control of wind turbines using dynamic weighted parallel firefly algorithm
    Mousavi, Yashar
    Bevan, Geraint
    Kucukdemiral, Ibrahim Beklan
    ISA TRANSACTIONS, 2022, 128 : 301 - 317
  • [29] Enhancement in the Operation of Wind Turbine Based Induction Generator by using Fuzzy Logic Based Direct Torque Control
    Ananth, D. V. N.
    2012 INTERNATIONAL CONFERENCE ON EMERGING TRENDS IN ELECTRICAL ENGINEERING AND ENERGY MANAGEMENT (ICETEEEM - 2012), 2012, : 159 - 165
  • [30] Constrained actuator fault tolerant control with the application to a wind turbine
    Witczak, Piotr
    Pazera, Marcin
    Patan, Krzysztof
    Witczak, Marcin
    IFAC PAPERSONLINE, 2018, 51 (24): : 1157 - 1163