Accuracy of the match between cone beam computed tomography and model scan data in template-guided implant planning: A prospective controlled clinical study

被引:29
作者
Schnutenhaus, Sigmar [1 ]
Groeller, Sebastian [1 ]
Luthardt, Ralph G. [1 ]
Rudolph, Heike [1 ]
机构
[1] Univ Ulm, Dept Prosthet Dent, Ctr Dent, Ulm, Germany
关键词
3D implant planning; CBCT; dental implants; drilling templates; model scan data; template-guided implantation; X-ray template; SURGICAL GUIDES; PLACEMENT; SURGERY; CAD/CAM;
D O I
10.1111/cid.12614
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
BackgroundTemplate-guided implant placement is a method for optimal implant positioning from a prosthetic and surgical viewpoint. The treatment planning is based on three-dimensional X-ray data and model scan data, as well as on prosthetic planning (set-up). These data are matched (superimposed) with the aid of an X-ray template or by manual matching without special referencing. PurposeThe objective of this prospective controlled clinical study was to determine and compare the accuracy of the match with and without an additional X-ray template. Materials and MethodsThe DICOM data of the cone beam computed tomography (CBCT) were converted into surface data sets and then superimposed on model scan data using three different methods (manually, based on an X-ray template, or semi-automatically with computer assistance). The mean deviations between these results of these matching methods were investigated. ResultsThe procedures achieved a matching accuracy of 0.2 mm on average. This corresponds to the resolution of the CBCT (0.2 voxels). Further studies are necessary to verify the procedure even for patients with few (0-4) residual teeth. ConclusionIn the presence of a sufficient number of residual teeth, the manual matching of model scan data with CBCT data is sufficiently accurate for implant planning and template-guided implementation. The results of the present study suggest that X-ray templates can be dispensed with saving the patient a substantial amount of time and money.
引用
收藏
页码:541 / 549
页数:9
相关论文
共 29 条
  • [1] An Open System Approach for Surgical Guide Production
    Abboud, Marcus
    Orentlicher, Gary
    [J]. JOURNAL OF ORAL AND MAXILLOFACIAL SURGERY, 2011, 69 (12) : E519 - E524
  • [2] Accuracy Assessment of Immediate and Delayed Implant Placements Using CAD/CAM Surgical Guides
    Alzoubi, Fawaz
    Massoomi, Nima
    Nattestad, Anders
    [J]. JOURNAL OF ORAL IMPLANTOLOGY, 2016, 42 (05) : 391 - 398
  • [3] Factors influencing transfer accuracy of cone beam CT-derived template-based implant placement
    Behneke, Alexandra
    Burwinkel, Matthias
    Behneke, Nikolaus
    [J]. CLINICAL ORAL IMPLANTS RESEARCH, 2012, 23 (04) : 416 - 423
  • [4] Accuracy assessment of cone beam computed tomography-derived laboratory-based surgical templates on partially edentulous patients
    Behneke, Alexandra
    Burwinkel, Matthias
    Knierim, Kristian
    Behneke, Nikolaus
    [J]. CLINICAL ORAL IMPLANTS RESEARCH, 2012, 23 (02) : 137 - 143
  • [5] Accuracy of computer-aided template-guided oral implant placement: a prospective clinical study
    Beretta, Mario
    Poli, Pier Paolo
    Maiorana, Carlo
    [J]. JOURNAL OF PERIODONTAL AND IMPLANT SCIENCE, 2014, 44 (04) : 184 - 193
  • [6] Registration of cone beam computed tomography data and intraoral surface scans - A prerequisite for guided implant surgery with CAD/CAM drilling guides
    Flugge, Tabea
    Derksen, Wiebe
    te Poel, Jobine
    Hassan, Bassam
    Nelson, Katja
    Wismeijer, Daniel
    [J]. CLINICAL ORAL IMPLANTS RESEARCH, 2017, 28 (09) : 1113 - 1118
  • [7] Geng W, 2015, INT J CLIN EXP MED, V8, P8442
  • [8] Cone-beam computed tomography in orthodontics: Benefits and limitations; [Die Digitale Volumentomographie in der Kieferorthopädie: Möglichkeiten und Grenzen]
    Holberg C.
    Steinhäuser S.
    Geis P.
    Rudzki-Janson I.
    [J]. Journal of Orofacial Orthopedics / Fortschritte der Kieferorthopädie, 2005, 66 (6): : 434 - 444
  • [9] Accuracy of Three-Dimensional Printed Templates for Guided Implant Placement Based on Matching a Surface Scan with CBCT
    Kernen, Florian
    Benic, Goran I.
    Payer, Michael
    Schar, Alex
    Muller-Gerbl, Magdalena
    Filippi, Andreas
    Kuhl, Sebastian
    [J]. CLINICAL IMPLANT DENTISTRY AND RELATED RESEARCH, 2016, 18 (04) : 762 - 768
  • [10] Technical Accuracy of Printed Surgical Templates for Guided Implant Surgery with the coDiagnostiX™ Software
    Kuehl, Sebastian
    Payer, Michael
    Zitzmann, Nicola Ursula
    Lambrecht, Joerg Thomas
    Filippi, Andreas
    [J]. CLINICAL IMPLANT DENTISTRY AND RELATED RESEARCH, 2015, 17 : E177 - E182