Potentiometric determination of cetylpyridinium chloride in oral desinfectants by flow injection analysis

被引:3
作者
Baptista, PCS [1 ]
Araújo, AN [1 ]
Montenegro, MDBSM [1 ]
机构
[1] CEQUP, Fac Farm, Dept Quim Fis, P-4050047 Oporto, Portugal
来源
QUIMICA NOVA | 2003年 / 26卷 / 04期
关键词
potentiometry; oral disinfectants; FIA;
D O I
10.1590/S0100-40422003000400005
中图分类号
O6 [化学];
学科分类号
0703 ;
摘要
The work describes a new procedure for cetylpyridinium chloride determination in oral disinfectants, based on a flow-injection system with potentiometric detection. The determination was based on the measurement of picrate concentration decrease as result of ion-pair reaction with the analyte present in the injected sample. In the optimised set-up the sample injection volume was kept at 400 muL and merged downstream with the reagent solution containing 10x10(-5) mol/L of picrate adjusted to pH 5.0 with citrate/citric acid buffer. The flow rate was fixed at 8 mL/min and the reactor length at 40 cm. The proposed procedure enables the determination of cetylpyridinium in the analytical range of 5,0x10(-6)-7,5x10(-5) mol/L at a sampling rate of 60/h. The results for real samples had a precision better than 3% and were comparable to the labelled values.
引用
收藏
页码:475 / 478
页数:4
相关论文
共 34 条
[1]   Cetylpyridinium-iodomercurate PVC membrane ion selective electrode for the determination of cetylpyridinium cation in Ezafluor mouth wash and as a detector for some potentiometric titrations [J].
Abbas, MN ;
Mostafa, GAE ;
Homoda, AMA .
TALANTA, 2000, 53 (02) :425-432
[2]  
ALEGRET S, 1987, QUIM ANAL, V6, P278
[3]  
BRENN DGP, 1995, ANAL CHEM, V67, P4210
[4]  
BUSCHMANN N, 1993, TENSIDE, V29, P128
[5]  
Campanella L, 1996, ANALUSIS, V24, P387
[6]  
CONNELL DW, 1997, BASIC CONCEPTS ENV C, P221
[7]   RECENT ADVANCES IN PHARMACEUTICAL ANALYSIS WITH POTENTIOMETRIC MEMBRANE SENSORS [J].
COSOFRET, VV ;
BUCK, RP .
CRITICAL REVIEWS IN ANALYTICAL CHEMISTRY, 1993, 24 (01) :1-58
[8]  
Egorov VV, 1996, J ANAL CHEM+, V51, P986
[9]   RAPID SCREENING METHOD FOR DITALLOWDIMETHYLAMMONIUM CHLORIDE AT THE LOW PPB LEVEL IN SURFACE-WATER USING SOLID-PHASE EXTRACTION AND NORMAL-PHASE LIQUID-CHROMATOGRAPHY WITH ONLINE POSTCOLUMN ION-PAIR EXTRACTION AND FLUORESCENCE DETECTION [J].
GORT, SM ;
HOGENDOORN, EA ;
BAUMANN, RA ;
VANZOONEN, P .
INTERNATIONAL JOURNAL OF ENVIRONMENTAL ANALYTICAL CHEMISTRY, 1993, 53 (04) :289-296
[10]   Determination of cationic surfactants by capillary electrophoresis with indirect photometric detection [J].
Heinig, K ;
Vogt, C ;
Werner, G .
JOURNAL OF CHROMATOGRAPHY A, 1997, 781 (1-2) :17-22