Percutaneous Coronary Intervention Under Cover of Left Ventricular Assist Device (Impella 2.5)

被引:0
作者
Iftikhar, Imran [1 ]
Khan, Hamid Sharif [1 ]
Kayani, Azhar Mahmood [1 ]
Shahzad, Hassan [1 ]
机构
[1] Rawalpindi Inst Cardiol, Dept Cardiol, Rawalpindi, Pakistan
来源
JCPSP-JOURNAL OF THE COLLEGE OF PHYSICIANS AND SURGEONS PAKISTAN | 2015年 / 25卷 / 10期
关键词
Left ventricular assist device (LVAD); Impella; 2.5; High risk percutaneous coronary intervention; CARDIOGENIC-SHOCK; FEASIBILITY; SAFETY; TRIAL;
D O I
暂无
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Impella 2.5 is a temporary left ventricular assist device that is being increasingly used in high risk Percutaneous Coronary intervention (PCI). It reduces the cardiac workload and provides assistance to myocardium and vital organs in states of severe left ventricular dysfunction and cardiogenic shock. We report the first case of successful percutaneous coronary stenting performed in a high risk patient using impella 2.5. A 65-year old diabetic and hypertensive male with a known double vessel coronary artery disease and a reduced left ventricular function (ejection fraction, 20%) was admitted with intractable angina. He was on optimal medical treatment for 2 months. His coronary angiogram done 2 months back had revealed double vessel coronary artery disease (subtotally occluded co-dominant left circumflex and moderate 60% stenosis in left anterior descending artery and a normal co-dominant right coronary artery). He was considered a high risk both for Coronary Artery Bypass Graft (CABG) surgery and PCI due to co-morbidities and reduced left ventricular function. As he had failed a trial of optimal medical therapy and the cardiac surgeon's reluctance for surgery, the patient and his family was counseled for high risk PCI with left ventricular assist device using the impella 2.5.
引用
收藏
页码:S78 / S80
页数:3
相关论文
共 10 条
[1]   The Use of Percutaneous Left Ventricular Assist Device in High-risk Percutaneous Coronary Intervention and Cardiogenic Shock [J].
Akhondi, Andre Babak ;
Lee, Michael S. .
REVIEWS IN CARDIOVASCULAR MEDICINE, 2013, 14 (2-4) :E144-E149
[2]  
Ali J, 2014, PAK ARMED FORCES MED, V1, pS114
[3]   Percutaneous left ventricular assist device: "TandemHeart" for high-risk coronary intervention [J].
Aragon, J ;
Lee, MS ;
Kar, S ;
Makkar, RR .
CATHETERIZATION AND CARDIOVASCULAR INTERVENTIONS, 2005, 65 (03) :346-352
[4]   A Prospective Feasibility Trial Investigating the Use of the Impel la 2.5 System in Patients Undergoing High-Risk Percutaneous Coronary Intervention (The PROTECT I Trial) Initial US Experience [J].
Dixon, Simon R. ;
Henriques, Jose P. S. ;
Mauri, Laura ;
Sjauw, Krischan ;
Civitello, Andrew ;
Kar, Biswajit ;
Loyalka, Pranav ;
Resnic, Frederic S. ;
Teirstein, Paul ;
Makkar, Raj ;
Palacios, Igor F. ;
Collins, Michael ;
Moses, Jeffrey ;
Benali, Karim ;
O'Neill, William W. .
JACC-CARDIOVASCULAR INTERVENTIONS, 2009, 2 (02) :91-96
[5]   Safety and feasibility of elective high-risk percutaneous coronary intervention procedures with left ventricular support of the Impella Recover LP 2.5 [J].
Henriques, JPS ;
Remmelink, M ;
Baan, J ;
van der Schaaf, RJ ;
Vis, MM ;
Koch, KT ;
Scholten, EW ;
de Mol, BAJM ;
Tijssen, JGP ;
Piek, JJ ;
de Winter, RJ .
AMERICAN JOURNAL OF CARDIOLOGY, 2006, 97 (07) :990-992
[6]  
Sarkar Kunal, 2010, Cardiol Clin, V28, P169, DOI 10.1016/j.ccl.2009.09.007
[7]   Percutaneous Coronary Intervention versus Coronary-Artery Bypass Grafting for Severe Coronary Artery Disease [J].
Serruys, Patrick W. ;
Morice, Marie-Claude ;
Kappetein, A. Pieter ;
Colombo, Antonio ;
Holmes, David R. ;
Mack, Michael J. ;
Stahle, Elisabeth ;
Feldman, Ted E. ;
van den Brand, Marcel ;
Bass, Eric J. ;
Van Dyck, Nic ;
Leadley, Katrin ;
Dawkins, Keith D. ;
Mohr, Friedrich W. .
NEW ENGLAND JOURNAL OF MEDICINE, 2009, 360 (10) :961-972
[8]   A Randomized Clinical Trial to Evaluate the Safety and Efficacy of a Percutaneous Left Ventricular Assist Device Versus Intra-Aortic Balloon Pumping for Treatment of Cardiogenic Shock Caused by Myocardial Infarction [J].
Seyfarth, Melchior ;
Sibbing, Dirk ;
Bauer, Iris ;
Froehlich, Georg ;
Bott-Fluegel, Lorenz ;
Byrne, Robert ;
Dirschinger, Josef ;
Kastrati, Adnan ;
Schoemig, Albert .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2008, 52 (19) :1584-1588
[9]   Supported High-Risk Percutaneous Coronary Intervention With the Impella 2.5 Device The Europella Registry [J].
Sjauw, Krischan D. ;
Konorza, Thomas ;
Erbel, Raimund ;
Danna, Paolo L. ;
Viecca, Maurizio ;
Minden, Hans-Heinrich ;
Butter, Christian ;
Engstrom, Thomas ;
Hassager, Christian ;
Machado, Francisco P. ;
Pedrazzini, Giovanni ;
Wagner, Daniel R. ;
Schamberger, Rainer ;
Kerber, Sebastian ;
Mathey, Detlef G. ;
Schofer, Joachim ;
Engstrom, Annemarie E. ;
Henriques, Jose P. S. .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2009, 54 (25) :2430-2434
[10]  
Vegas Annette, 2008, Anesthesiol Clin, V26, P539, DOI 10.1016/j.anclin.2008.03.001