Laboratory Evaluation of the gForce Tracker™, a Head Impact Kinematic Measuring Device for Use in Football Helmets

被引:59
作者
Campbell, Kody R. [1 ,4 ]
Warnica, Meagan J. [2 ]
Levine, Iris C. [2 ]
Brooks, Jeffrey S. [1 ]
Laing, Andrew C. [2 ]
Burkhart, Timothy A. [3 ]
Dickey, James P. [1 ]
机构
[1] Western Univ, Sch Kinesiol, Joint Biomech Lab, Thames Hall,1151 Richmond St, London, ON N6A 3K7, Canada
[2] Univ Waterloo, Dept Kinesiol, Injury Biomech & Aging Lab, 200 Univ Ave West, Waterloo, ON N2L 3G1, Canada
[3] Western Univ, Mech & Mat Engn, Thompson Engn Bldg,1151 Richmond St, London, ON N6A 5B9, Canada
[4] Univ N Carolina, Dept Allied Hlth Sci, Stallings Evans Sports Med Ctr 2207, Campus Box 8700, Chapel Hill, NC 27599 USA
基金
加拿大自然科学与工程研究理事会;
关键词
Concussion; mTBI; Head acceleration; Head impact biomechanics; Impact monitoring; Helmet sensors; TRAUMATIC BRAIN-INJURY; PROFESSIONAL FOOTBALL; RECURRENT CONCUSSION; ACCELERATION; EPIDEMIOLOGY; DIRECTION; SYSTEM; RISK;
D O I
10.1007/s10439-015-1391-7
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
This study sought to compare a new head impact-monitoring device, which is not limited to specific helmet styles, against reference accelerometer measurements. Laboratory controlled impacts were delivered using a linear pneumatic impactor to a Hybrid III headform (HIII) fitted with a football helmet and the impact monitoring device (gForce Tracker-GFT) affixed to the inside of the helmet. Linear regression analyses and absolute mean percent error (MAPE) were used to compare the head impact kinematics measured by the GFT to a reference accelerometer located at the HIII's center of mass. The coefficients of determination were strong for the peak linear acceleration, peak rotational velocity, and HIC15 across all impact testing locations (r (2) = 0.82, 0.94, and 0.70, respectively), but there were large MAPE for the peak linear acceleration and HIC15 (MAPE = 49 +/- A 21% and 108 +/- A 58%). The raw GFT was accurate at measuring the peak rotational velocity at the center of mass of the HIII (MAPE = 9%). Results from the impact testing were used to develop a correction algorithm. The coefficients of determination for all impact parameters improved using the correction algorithm for the GFT (r (2) > 0.97), and the MAPE were less than 14%. The GFT appears to be a suitable impact-monitoring device that is not limited to specific styles of football helmets, however, correction algorithms will need to be developed for each helmet style.
引用
收藏
页码:1246 / 1256
页数:11
相关论文
共 30 条
[1]  
Allison M., 2014, Annals of biomedical engineering
[2]   Measuring Head Kinematics in Football: Correlation Between the Head Impact Telemetry System and Hybrid III Headform [J].
Beckwith, Jonathan G. ;
Greenwald, Richard M. ;
Chu, Jeffrey J. .
ANNALS OF BIOMEDICAL ENGINEERING, 2012, 40 (01) :237-248
[3]  
Bland JM, 1999, STAT METHODS MED RES, V8, P135, DOI 10.1177/096228029900800204
[4]   An Instrumented Mouthguard for Measuring Linear and Angular Head Impact Kinematics in American Football [J].
Camarillo, David B. ;
Shull, Pete B. ;
Mattson, James ;
Shultz, Rebecca ;
Garza, Daniel .
ANNALS OF BIOMEDICAL ENGINEERING, 2013, 41 (09) :1939-1949
[5]  
Cichos D., 2006, Workgroup Data Processing ..., October
[6]  
Cobb B. R., 2014, P I MECH ENG P-J SPO
[7]  
DiMasi F, 1995, TECHNICAL REPORT
[8]  
GURDJIAN ES, 1961, SURG GYNECOL OBSTET, V113, P185
[9]   Recurrent concussion and risk of depression in retired professional football players [J].
Guskiewicz, Kevin M. ;
Marshall, Stephen W. ;
Bailes, Julian ;
McCrea, Michael ;
Harding, Herndon P., Jr. ;
Matthews, Amy ;
Mihalik, Johna Register ;
Cantu, Robert C. .
MEDICINE AND SCIENCE IN SPORTS AND EXERCISE, 2007, 39 (06) :903-909
[10]   Association between recurrent concussion and late-life cognitive impairment in retired professional football players [J].
Guskiewicz, KM ;
Marshall, SW ;
Bailes, J ;
McCrea, M ;
Cantu, RC ;
Randolph, C ;
Jordan, BD .
NEUROSURGERY, 2005, 57 (04) :719-724