Contrast-enhanced magnetic resonance angiography - P792 blood pool agent versus Gd-DOTA in rabbits at 3.0 T versus 1.5 T

被引:9
|
作者
Herborn, Christoph U.
Watkins, David M.
Baumann, Shannon
Robert, Philippe
Corot, Claire
Runge, Val M.
机构
[1] Med Univ Ctr Hamburg Eppendorf, MPCH, D-20251 Hamburg, Germany
[2] Scott & White Mem Hosp & Clin, Dept Radiol, Temple, TX USA
[3] Aulnay Sous Bois, Guerbet Res, Paris, France
关键词
MRA; 3; T; blood pool agent; P792;
D O I
10.1097/RLI.0b013e318059b58b
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: To assess the gadolinium-based macromolecular intravascular contrast agent P792 for magnetic resonance angiography (MRA) at magnetic field strengths of 3.0 T, in comparison to 1.5 T, in rabbits. Materials and Methods: Eleven female New Zealand rabbits of the same age served as the animal model. Dose relationship testing was performed with 2 doses (13 and 25 [mu mol/kg; n = 4 per group) of P792 as compared with a single dose (100 mu mol/kg; n = 3) of gadoterate meglumine (Gd-DOTA). All animals underwent contrast-enhanced MRA of the abdominal aorta and its branches on 2 occasions separated by 72 hours. The particular doses were administered in random order. Contrast-enhanced MRA was performed on 3.0 and 1.5 T whole-body MR systems, using a fast 3D spoiled gradient recalled echo sequence. Data acquisition was performed before and up to 10 minutes after administration of intravenous contrast material. Image quality was judged on a 4-point-Likert scale. Signal-to-noise and contrast-to-noise measurements were performed; statistical differences (P < 0.05) between the groups were determined. Results: P792 and Gd-DOTA yielded high-quality MR angiograms in rabbits in all cases. Although image quality within the first 3 minutes after contrast material administration was equal for both agents, P792 at a dose of 25 mu mol/kg was considered superior to Gd-DOTA at the later time points. Signal-to-noise and contrast-to-noise values of the higher dose of P792 were statistically significantly higher than those of Gd-DOTA in the post-bolus phase. Conclusions: P792 seems to be well suited for high-quality early phase and equilibrium phase MRA in rabbits at a field strength of 3.0 T, on the basis of this initial evaluation in an animal model.
引用
收藏
页码:622 / 628
页数:7
相关论文
共 50 条
  • [21] Active gastrointestinal hemorrhage identification by blood pool contrast-enhanced magnetic resonance angiography
    Jonathan Williams
    Shreyas S. Vasanawala
    Pediatric Radiology, 2011, 41 : 1198 - 1200
  • [22] Active gastrointestinal hemorrhage identification by blood pool contrast-enhanced magnetic resonance angiography
    Williams, Jonathan
    Vasanawala, Shreyas S.
    PEDIATRIC RADIOLOGY, 2011, 41 (09) : 1198 - 1200
  • [23] Comparison of the High Relaxivity Gd Chelates P1152 and Gd-BOPTA for Contrast-Enhanced MR Angiography in Rabbits at 1.5 Tesla and 3.0 Tesla
    Peldschus, Kersten
    Hamdorf, Mareike
    Robert, Philippe
    Port, Marc
    Adam, Gerhard
    Herborn, Christoph U.
    JOURNAL OF MAGNETIC RESONANCE IMAGING, 2010, 32 (02) : 459 - 465
  • [24] Contrast-enhanced magnetic resonance cholangiography versus heavily T2-weighted magnetic resonance cholangiography
    Papanikolaou, N
    Prassopoulos, P
    Eracleous, E
    Maris, T
    Gogas, C
    Gourtsoyiannis, N
    INVESTIGATIVE RADIOLOGY, 2001, 36 (11) : 682 - 686
  • [25] Blood Pool Contrast-enhanced Magnetic Resonance Angiography with Correlation to Digital Subtraction Angiography: A Pictorial Review
    Knuttinen, Martha-Grace
    Karow, Jillian
    Mar, Winnie
    Golden, Margaret
    Xie, Karen L.
    JOURNAL OF CLINICAL IMAGING SCIENCE, 2014, 4
  • [26] Non-enhanced versus low-dose contrast-enhanced renal magnetic resonance angiography at 7 T: a feasibility study
    Laader, Anja
    Beiderwellen, Karsten
    Kraff, Oliver
    Maderwald, Stefan
    Ladd, Mark E.
    Forsting, Michael
    Umutlu, Lale
    ACTA RADIOLOGICA, 2018, 59 (03) : 296 - 304
  • [27] Contrast-Enhanced Magnetic Resonance Angiography Evaluation of the High Relaxivity Low Diffusible Gadolinium-Based Contrast Agent P846 in Comparison With Gadoterate Meglumine in Rabbits at 1.5 Tesla and 3.0 Tesla
    Peldschus, Kersten
    Hamdorf, Mereike
    Robert, Philippe
    Port, Marc
    Graessner, Joachim
    Adam, Gerhard
    Herborn, Christoph U.
    INVESTIGATIVE RADIOLOGY, 2008, 43 (12) : 837 - 842
  • [28] Effect of field strengths on magnetic resonance angiography - Comparison of an ultrasmall superparamagnetic iron oxide blood-pool contrast agent and gadopentetate dimeglumine in rabbits at 1.5 and 3.0 tesla
    Allkemper, T
    Heindel, W
    Kooijman, H
    Ebert, W
    Tombach, B
    INVESTIGATIVE RADIOLOGY, 2006, 41 (02) : 97 - 104
  • [29] Assessment of Moyamoya Disease With 3.0-T Magnetic Resonance Angiography and Magnetic Resonance Imaging Versus Conventional Angiography
    Jin, Qianna
    Noguchi, Tomoyuki
    Irie, Hiroyuki
    Kawashima, Masatou
    Nishihara, Masashi
    Takase, Yukinori
    Gong, Honghan
    Uchino, Akira
    Matsushima, Toshio
    Kudo, Sho
    NEUROLOGIA MEDICO-CHIRURGICA, 2011, 51 (03) : 195 - 200
  • [30] Total-body contrast-enhanced MRA on a short, wide-bore 1.5-T system: intra-individual comparison of Gd-BOPTA and Gd-DOTA
    M. Rasmus
    J. Bremerich
    T. Egelhof
    R. W. Huegli
    G. Bongartz
    D. Bilecen
    European Radiology, 2008, 18 : 2265 - 2273