Contrast-enhanced magnetic resonance angiography - P792 blood pool agent versus Gd-DOTA in rabbits at 3.0 T versus 1.5 T

被引:9
|
作者
Herborn, Christoph U.
Watkins, David M.
Baumann, Shannon
Robert, Philippe
Corot, Claire
Runge, Val M.
机构
[1] Med Univ Ctr Hamburg Eppendorf, MPCH, D-20251 Hamburg, Germany
[2] Scott & White Mem Hosp & Clin, Dept Radiol, Temple, TX USA
[3] Aulnay Sous Bois, Guerbet Res, Paris, France
关键词
MRA; 3; T; blood pool agent; P792;
D O I
10.1097/RLI.0b013e318059b58b
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: To assess the gadolinium-based macromolecular intravascular contrast agent P792 for magnetic resonance angiography (MRA) at magnetic field strengths of 3.0 T, in comparison to 1.5 T, in rabbits. Materials and Methods: Eleven female New Zealand rabbits of the same age served as the animal model. Dose relationship testing was performed with 2 doses (13 and 25 [mu mol/kg; n = 4 per group) of P792 as compared with a single dose (100 mu mol/kg; n = 3) of gadoterate meglumine (Gd-DOTA). All animals underwent contrast-enhanced MRA of the abdominal aorta and its branches on 2 occasions separated by 72 hours. The particular doses were administered in random order. Contrast-enhanced MRA was performed on 3.0 and 1.5 T whole-body MR systems, using a fast 3D spoiled gradient recalled echo sequence. Data acquisition was performed before and up to 10 minutes after administration of intravenous contrast material. Image quality was judged on a 4-point-Likert scale. Signal-to-noise and contrast-to-noise measurements were performed; statistical differences (P < 0.05) between the groups were determined. Results: P792 and Gd-DOTA yielded high-quality MR angiograms in rabbits in all cases. Although image quality within the first 3 minutes after contrast material administration was equal for both agents, P792 at a dose of 25 mu mol/kg was considered superior to Gd-DOTA at the later time points. Signal-to-noise and contrast-to-noise values of the higher dose of P792 were statistically significantly higher than those of Gd-DOTA in the post-bolus phase. Conclusions: P792 seems to be well suited for high-quality early phase and equilibrium phase MRA in rabbits at a field strength of 3.0 T, on the basis of this initial evaluation in an animal model.
引用
收藏
页码:622 / 628
页数:7
相关论文
共 50 条
  • [1] Comparison of 1.5 and 3.0 T for Contrast-Enhanced Pulmonary Magnetic Resonance Angiography
    Londy, Frank Joseph
    Lowe, Suzan
    Stein, Paul D.
    Weg, John G.
    Eisner, Robert L.
    Leeper, Kenneth V.
    Woodard, Pamela K.
    Sostman, H. Dirk
    Jablonski, Kathleen A.
    Fowler, Sarah E.
    Hales, Charles A.
    Hull, Russell D.
    Gottschalk, Alexander
    Naidich, David P.
    Chenevert, Thomas L.
    CLINICAL AND APPLIED THROMBOSIS-HEMOSTASIS, 2012, 18 (02) : 134 - 139
  • [2] MR angiography with a new rapid clearance blood pool agent (P792): Initial experience in rabbits
    Ruehm, SG
    Schmitz-Cristina, H
    Violas, X
    Corot, C
    Debatin, JF
    ACADEMIC RADIOLOGY, 2002, 9 : S407 - S408
  • [3] Coronary magnetic resonance angiography: Experimental evaluation of the new rapid clearance blood pool contrast medium P792
    Taupitz, M
    Schnorr, J
    Wagner, S
    Kivelitz, D
    Rogalla, P
    Claassen, G
    Dewey, M
    Robert, P
    Corot, C
    Hamm, B
    MAGNETIC RESONANCE IN MEDICINE, 2001, 46 (05) : 932 - 938
  • [4] Coronary magnetic resonance angiography: Experimental evaluation of the new rapid clearance blood pool contrast medium P792
    Taupitz, Matthias
    Schnorr, Jorg
    Wagner, Susanne
    Kivelitz, Dietmar
    Rogalla, Patrik
    Claa, Gerlind
    Dewey, Marc
    Robert, Philippe
    Corot, Claire
    Hamm, Bernd
    2001, John Wiley and Sons Inc. (46)
  • [5] Comparison of the tumoral biodistribution of P792, a rapid clearance blood pool agent and Gd-DOTA in a C6 glioma cerebral tumor model in rats
    Robert, P
    Santus, R
    Violas, X
    Rémy, C
    Corot, C
    ACADEMIC RADIOLOGY, 2002, 9 : S521 - S524
  • [6] P792: a rapid clearance blood pool agent for magnetic resonance imaging: preliminary results
    Marc Port
    Claire Corot
    Olivier Rousseaux
    Isabelle Raynal
    Ludovic Devoldere
    Jean-Marc Idée
    Anne Dencausse
    Soizic Le Greneur
    C. Simonot
    Dominique Meyer
    Magnetic Resonance Materials in Physics, Biology and Medicine, 2001, 12 : 121 - 127
  • [7] P792:: a rapid clearance blood pool agent for magnetic resonance imaging:: preliminary results
    Port, M
    Corot, C
    Rousseaux, O
    Raynal, I
    Devoldere, L
    Idée, JM
    Dencausse, A
    Le Greneur, S
    Simonot, C
    Meyer, D
    MAGNETIC RESONANCE MATERIALS IN PHYSICS BIOLOGY AND MEDICINE, 2001, 12 (2-3) : 121 - 127
  • [8] Renal functional contrast-enhanced magnetic resonance imaging - Evaluation of a new rapid-clearance blood pool agent (P792) in Sprague-Dawley rats
    Mandry, D
    Pedersen, M
    Odille, F
    Robert, P
    Corot, C
    Felblinger, J
    Grenier, N
    Claudon, M
    INVESTIGATIVE RADIOLOGY, 2005, 40 (05) : 295 - 305
  • [9] Gated thoracic magnetic resonance angiography at 3T: noncontrast versus blood pool contrast
    Chengcheng Zhu
    Henrik Haraldsson
    Kimberly Kallianos
    Liang Ge
    Elaine Tseng
    Travis Henry
    David Saloner
    Michael D. Hope
    The International Journal of Cardiovascular Imaging, 2018, 34 : 475 - 483
  • [10] Gated thoracic magnetic resonance angiography at 3T: noncontrast versus blood pool contrast
    Zhu, Chengcheng
    Haraldsson, Henrik
    Kallianos, Kimberly
    Ge, Liang
    Tseng, Elaine
    Henry, Travis
    Saloner, David
    Hope, Michael D.
    INTERNATIONAL JOURNAL OF CARDIOVASCULAR IMAGING, 2018, 34 (03): : 475 - 483