Post-cooling properties of concrete exposed to fire

被引:48
作者
Botte, Wouter [1 ]
Caspeele, Robby [1 ]
机构
[1] Univ Ghent, Dept Struct Engn, Technol Pk Zwijnaarde 904, B-9052 Zwijnaarde, Belgium
关键词
HIGH-TEMPERATURES; ELEVATED-TEMPERATURES; COMPRESSIVE STRENGTH; REINFORCED-CONCRETE; RESIDUAL STRENGTH; DAMAGED CONCRETE; BOND; STEEL; PERFORMANCE;
D O I
10.1016/j.firesaf.2017.06.010
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
Concrete structures are able to resist high temperatures due to fire relatively well and they can be repaired afterwards. In order to select appropriate repair strategies, assessment of the condition of a concrete structure after fire is of crucial importance. Previous research has mostly been focusing on the strength of concrete during fire and considering slow cooling of elements to room temperature. Guidelines and models related to these conditions have been incorporated into structural design codes. However, in reality, fast cooling of concrete by means of water occurs frequently and the effect of this cooling method has been much less the subject of research investigations. Nevertheless, the effect of water cooling can be significant. In this article the effect of water cooling on the residual compressive strength, stress-strain diagram and bond strength between concrete and reinforcement is investigated. Two cooling methods are considered,, i.e. quenching and spraying of specimens. It is found that the investigated properties are extremely sensitive to heating with subsequent water cooling.
引用
收藏
页码:142 / 150
页数:9
相关论文
共 50 条
[41]   Post-Fire Mechanical Properties of Concrete Reinforced with Spanish Broom Fibers [J].
Juradin, Sandra ;
Vranjes, Lidia Karla ;
Jozic, Drazan ;
Boko, Ivica .
JOURNAL OF COMPOSITES SCIENCE, 2021, 5 (10)
[42]   Post-fire seismic performance of reinforced concrete structures [J].
Duzgun, Oguz Akin ;
Kucuk, Elif Nazli .
STRUCTURES, 2024, 59
[43]   Study on the post-fire properties of concrete with recycled tyre polymer fibres [J].
Rukavina, Marija Jelcic ;
Baricevic, Ana ;
Serdar, Marijana ;
Grubor, Martina .
CEMENT & CONCRETE COMPOSITES, 2021, 123
[44]   Residual strength and microstructure of fiber reinforced self-compacting concrete exposed to high temperatures [J].
Sadrmomtazi, Ali ;
Gashti, Saeed Haghighat ;
Tahmouresi, Behzad .
CONSTRUCTION AND BUILDING MATERIALS, 2020, 230
[45]   Behavior of MK-based Geopolymer Concrete Circular Columns Exposed to Fire [J].
Khalid, Nibras N. ;
Al-Saraj, Wissam K. ;
Naji, Hanadi F. .
JOURNAL OF APPLIED SCIENCE AND ENGINEERING, 2021, 24 (01) :91-97
[46]   Effect of polypropylene and glass fiber on properties of lightweight concrete exposed to high temperature [J].
Ghanim, Abdulnour Ali Jazem ;
Amin, Mohamed ;
Zeyad, Abdullah M. ;
Tayeh, Bassam A. ;
Agwa, Ibrahim Saad ;
Elsakhawy, Yara .
ADVANCES IN CONCRETE CONSTRUCTION, 2023, 15 (03) :179-190
[47]   Numerical investigation of damage and spalling in concrete exposed to fire [J].
Davie, C. T. ;
Zhang, H. L. .
COMPUTATIONAL MODELLING OF CONCRETE STRUCTURES, 2010, :775-784
[48]   Prediction of response of reinforced concrete frames exposed to fire [J].
Balaji, Aneesha ;
Luquman, Muhamed K. ;
Nagarajan, Praveen ;
Pillai, T. M. Madhavan .
ADVANCES IN COMPUTATIONAL DESIGN, 2016, 1 (01) :105-117
[49]   Posttensioned Concrete Bridge Beams Exposed to Hydrocarbon Fire [J].
Wu, Xi-qiang ;
Huang, Ting ;
Au, Francis Tat Kwong ;
Li, Jing .
JOURNAL OF STRUCTURAL ENGINEERING, 2020, 146 (10)
[50]   Thermal behaviour of autoclaved aerated concrete exposed to fire [J].
Karim, Ghazi Wakili ;
Hugi, E. ;
Karvonen, L. ;
Schnewlin, P. ;
Winnefeld, F. .
CEMENT & CONCRETE COMPOSITES, 2015, 62 :52-58