Development of an immunoassay and a sol-gel-based immunoaffinity cleanup method for coplanar polychlorinated biphenyls from soil and sediment samples

被引:13
作者
Altstein, Miriam [1 ]
Ben Aziz, Orna [1 ]
Skalka, Nir [1 ]
Bronshtein, Alisa [1 ]
Chuang, Jane C. [2 ]
Van Emon, Jeanette M. [3 ]
机构
[1] Agr Res Org, Volcani Ctr, Dept Entomol, IL-50250 Bet Dagan, Israel
[2] Battelle Mem Inst, Columbus, OH 43201 USA
[3] US EPA, Natl Exposure Res Lab, Las Vegas, NV 89193 USA
基金
美国国家环境保护局;
关键词
Coplanar polychlorinated biphenyls; Enzyme linked immunosorbent assay; Sol-gel; Immunoaffinity cleanup; Residue monitoring; LINKED-IMMUNOSORBENT-ASSAY; CHROMATOGRAPHY-MASS-SPECTROMETRY; TETRACHLORODIBENZO-P-DIOXIN; TOXIC EQUIVALENCY FACTORS; TRACE-ANALYSIS; POLYCLONAL ANTIBODIES; ENZYME-IMMUNOASSAY; SERUM SAMPLES; RETAIL FISH; PCBS;
D O I
10.1016/j.aca.2010.07.018
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Two polychlorinated biphenyls (PCB) enzyme linked immunosorbent assays (ELISAs) were developed using goat PCB purified immunoglobulin (IgG) antibodies (Abs). The IgGs exhibited the highest affinity toward PCB-77 (24 ng mL(-1)) with sensitivities in the range of 6-11 ng mL(-1). The Abs cross-reacted with PCB-126 and the heptachlorodibenzofuran 1,2,3,4,6,7,8-HpCDF but not with PCB-169, PCB-118, Aroclor 1232, 1248, 1260 or the hexachlorodibenzofuran 2,3,4,6,7,8-HxCDF. The IgGs were also used to develop a sol-gel-based immunoaffinity purification (IAP) method for cleanup of PCB-126. Recovery efficiencies depended on the sol-gel formats; a 1:12 format resulted in the highest binding capacity. Net binding capacity ranged from 112 to 257 ng, and 90% of the analyte could be eluted with only 2 mL of ethanol. The method was also very efficient in purifying PCB-126 from spiked soil and sediment samples from contaminated sites; and eliminating matrix interferences to a degree that enabled analysis of the purified samples by ELISA. The approaches developed in the course of the study form a basis for the development of additional IAP methods for other PCBs, and their implementation in high-throughput screening programs for PCB in food, soil, and other environmental and biological samples. (C) 2010 Elsevier B.V. All rights reserved.
引用
收藏
页码:138 / 147
页数:10
相关论文
共 51 条
[1]   Immunochemical approaches for purification and detection of TNT traces by antibodies entrapped in a sol-gel matrix [J].
Altstein, M ;
Bronshtein, A ;
Glattstein, B ;
Zeichner, A ;
Tamiri, T ;
Almog, J .
ANALYTICAL CHEMISTRY, 2001, 73 (11) :2461-2467
[2]  
ALTSTEIN M, 2005, IMMUNOASSAY OTHER BI, P357
[3]  
[Anonymous], EPA600R04036
[4]   Polychlorinated biphenyls in contaminated soil samples evaluated by GC-ECD with dual-column and GC-HRMS [J].
Bianco, Giuliana ;
Novario, Giuseppe ;
Bochicchio, Dominga ;
Anzilotta, Giuseppe ;
Palma, Achille ;
Cataldi, Tommaso R. I. .
CHEMOSPHERE, 2008, 73 (01) :104-112
[5]   Sol-gel matrixes doped with atrazine antibodies: Atrazine binding properties [J].
Bronshtein, A ;
Aharonson, N ;
Avnir, D ;
Turniansky, A ;
Altstein, M .
CHEMISTRY OF MATERIALS, 1997, 9 (11) :2632-2639
[6]   Sol-gel-based immunoaffinity chromatography: Application to nitroaromatic compounds [J].
Bronshtein, A ;
Aharonson, N ;
Turniansky, A ;
Altstein, M .
CHEMISTRY OF MATERIALS, 2000, 12 (07) :2050-2058
[7]   Analysis of soil and dust samples for polychlorinated biphenyls by enzyme-linked immunosorbent assay (ELISA) [J].
Chuang, JC ;
Miller, LS ;
Davis, DB ;
Peven, CS ;
Johnson, JC ;
Van Emon, JM .
ANALYTICA CHIMICA ACTA, 1998, 376 (01) :67-75
[8]   Determination of sulfonylurea herbicides in water and food samples using sol-gel glass-based immunoaffinity extraction and liquid chromatography-ultraviolet/diode array detection or liquid chromatography-tandem mass spectrometry [J].
Degelmann, P ;
Egger, S ;
Jürling, H ;
Müller, J ;
Niessner, R ;
Knopp, D .
JOURNAL OF AGRICULTURAL AND FOOD CHEMISTRY, 2006, 54 (06) :2003-2011
[9]   Immunoaffinity solid-phase extraction for pharmaceutical and biomedical trace-analysis-coupling with HPLC and CE-perspectives [J].
Delaunay-Bertoncini, N ;
Hennion, MC .
JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2004, 34 (04) :717-736
[10]   Direct competitive ELISA for the determination of polychlorinated biphenyls in soil samples [J].
Deng, AP ;
Kolár, V ;
Ulrich, R ;
Fránek, M .
ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2002, 373 (08) :685-690