Dosimetric evaluation of a new design MOSFET in vivo dosimeter

被引:59
作者
Halvorsen, PH [1 ]
机构
[1] Middlesex Hosp, Dept Radiat Oncol, Middletown, CT 06457 USA
关键词
D O I
10.1118/1.1827771
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
A single-use dosimeter, designed for in vivo patient dosimetry, has been evaluated. Key dosimetric characteristics of the dosimetry system have been measured for high-energy photon and electron beams commonly used in external beam therapy. Under the measurement conditions utilized, dose accuracy was within 5% for all data points, and inter-batch uniformity was acceptable, with a standard deviation of 1.7%. Dose linearity was confirmed for doses ranging from 2 to 400 cGy. The dosimeter readings were independent of dose rate for rates ranging from 80 to 480 cGy/min. When used as instructed, the dosimeter readings were accurate across the tested range of energy and modality. These measurements show that the dosimetry system's performance may be acceptable for in vivo dosimetry of entrance d(max) doses. (C) 2005 American Association of Physicists in Medicine.
引用
收藏
页码:110 / 117
页数:8
相关论文
共 14 条
  • [1] [Anonymous], 1983, MED PHYS, V10, P741
  • [2] A new radiotherapy surface dose detector: The MOSFET
    Butson, MJ
    Rozenfeld, A
    Mathur, JN
    Carolan, M
    Wong, TPY
    Metcalfe, PE
    [J]. MEDICAL PHYSICS, 1996, 23 (05) : 655 - 658
  • [3] Investigation of the use of MOSFET for clinical IMRT dosimetric verification
    Chuang, CF
    Verhey, LJ
    Xia, P
    [J]. MEDICAL PHYSICS, 2002, 29 (06) : 1109 - 1115
  • [4] DRESSENDORFER P, 1989, IONIZING RADIATION E
  • [5] Moldable tissue equivalent bolus for high-energy photon and electron therapy
    Dubois, D
    Bice, W
    Bradford, B
    Schneid, T
    Engelmeier, R
    [J]. MEDICAL PHYSICS, 1996, 23 (09) : 1547 - 1549
  • [6] TIME-RESOLVED HOLE TRANSPORT IN ALPHA-SIO2
    HUGHES, RC
    [J]. PHYSICAL REVIEW B, 1977, 15 (04): : 2012 - 2020
  • [7] MINIATURE RADIATION DOSIMETER FOR INVIVO RADIATION MEASUREMENTS
    HUGHES, RC
    HUFFMAN, D
    SNELLING, JV
    ZIPPERIAN, TE
    RICCO, AJ
    KELSEY, CA
    [J]. INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1988, 14 (05): : 963 - 967
  • [8] CHARGE-CARRIER TRANSPORT PHENOMENA IN AMORPHOUS SIO2 - DIRECT MEASUREMENT OF DRIFT MOBILITY AND LIFETIME
    HUGHES, RC
    [J]. PHYSICAL REVIEW LETTERS, 1973, 30 (26) : 1333 - 1336
  • [9] Comparison study of MOSFET detectors and diodes for entrance in vivo dosimetry in 18 MV x-ray beams
    Jornet, N
    Carrasco, P
    Jurado, D
    Ruiz, A
    Eudaldo, T
    Ribas, M
    [J]. MEDICAL PHYSICS, 2004, 31 (09) : 2534 - 2542
  • [10] Clinical dosimetry using MOSFETS
    Ramani, R
    Russell, S
    OBrien, P
    [J]. INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1997, 37 (04): : 959 - 964