Utility of three-dimensional computed tomography for the surgical management of rib fractures

被引:16
作者
Pulley, Benjamin R. [1 ]
Taylor, Benjamin C. [2 ]
Fowler, Terry Ty [1 ]
Dominguez, Neysa [2 ]
Trinh, Thai Q. [1 ]
机构
[1] Grant Med Ctr, Dept Orthopaed Surg, Columbus, OH USA
[2] Grant Med Ctr, Dept Orthopaed Surg, Mt Carmel Hlth Syst, Columbus, OH USA
关键词
Three-dimensional computed tomography; flail chest; rib fractures; rib fracture fixation; flail chest imaging; BLUNT CHEST TRAUMA; FLAIL CHEST; INTEROBSERVER RELIABILITY; HUMERAL FRACTURES; WALL INJURIES; CLASSIFICATION; FIXATION; CT; MORTALITY; MORBIDITY;
D O I
10.1097/TA.0000000000000563
中图分类号
R4 [临床医学];
学科分类号
1002 ; 100602 ;
摘要
BACKGROUND: Surgical stabilization of flail chest is increasingly recognized as a valid approach to improve pulmonary mechanics in selected trauma patients. The use of two-dimensional (2D) computed tomography (CT) has become almost universal in the assessment of blunt chest trauma and multiple rib fractures. We hypothesized that three-dimensional (3D) CT adds valuable information to the preoperative plan for fixation of rib fractures. METHODS: Using a retrospective cohort of 35 consecutive adult patients with flail chest requiring surgery, we evaluated the intraobserver and interobserver reliability of plain radiographs, 2D CT and 3D CT, for the identification of rib fractures and identified how often the surgical plan changed with the addition of the information provided by the 3D CT. Two fellowship-trained orthopedic trauma surgeons who regularly operate on rib fractures in their clinical practice and were not involved in the treatment of the study population evaluated the radiographic data. RESULTS: Intraobserver and interobserver reliability was excellent for both 2D CT and 3D CT and was the highest for 2D CT. Overall, 2D CT had the highest diagnostic accuracy for detecting rib fractures as compared with plain radiographs and 3D CT. However, 3D CT changed the surgical tactic in 65.7% of the cases. CONCLUSION: We conclude that 3D CT is not as accurate as 2D CT for rib fracture diagnostic purposes; it seems to be an important tool for the preoperative planning of rib fracture fixation. (Copyright (C) 2015 Wolters Kluwer Health, Inc. All rights reserved.)
引用
收藏
页码:530 / 534
页数:5
相关论文
共 50 条
  • [21] A three-dimensional computed tomography study of the palmar ulnar corner fragment in distal radial fractures
    Hubbard, James
    Berry, David
    Chauhan, Aakash
    Casstevens, Chris
    Shin, Alexander Y.
    Abrams, Reid A.
    JOURNAL OF HAND SURGERY-EUROPEAN VOLUME, 2024, 49 (03) : 300 - 309
  • [22] Three-dimensional computed tomography imaging increases the reliability of classification systems for tibial plateau fractures
    Hu, Yan-Ling
    Ye, Fa-Gang
    Ji, Ai-Yu
    Qiao, Guang-Xi
    Liu, Hai-Fei
    INJURY-INTERNATIONAL JOURNAL OF THE CARE OF THE INJURED, 2009, 40 (12): : 1282 - 1285
  • [23] Surgical rib fixation as an alternative method of treatment for multiple rib fractures: an audit of results compared with traditional medical management
    Monzou, B., I
    Fingleson, L. M.
    Moeng, M. S.
    SOUTH AFRICAN JOURNAL OF SURGERY, 2021, 59 (03) : 86 - +
  • [24] Evaluation of styloid process by three-dimensional computed tomography
    C. Çınar Başekim
    Hakan Mutlu
    Atila Güngör
    Emir Şilit
    Zekai Pekkafali
    Murat Kutlay
    Ahmet Çolak
    Ersin Öztürk
    Eşref Kizilkaya
    European Radiology, 2005, 15 : 134 - 139
  • [25] Perovskite computed tomography imager and three-dimensional reconstruction
    He, Yuhong
    Song, Jinmei
    Li, Mingbian
    Sakhatskyi, Kostiantyn
    Li, Weijun
    Feng, Xiaopeng
    Yang, Bai
    Kovalenko, Maksym
    Wei, Haotong
    NATURE PHOTONICS, 2024, 18 (10) : 1052 - 1058
  • [26] Three-Dimensional Computed Tomography in the Cardiac Catheterization Laboratory
    Krishnaswamy, Amar
    Tuzcu, E. Murat
    Kapadia, Samir R.
    CATHETERIZATION AND CARDIOVASCULAR INTERVENTIONS, 2011, 77 (06) : 860 - 865
  • [27] Application of three-dimensional computed tomography for the rheumatoid wrist
    Ji Hyeon Ju
    Kwi Young Kang
    In Je Kim
    Jang Uk Yoon
    Ho-Youn Kim
    Sung-Hwan Park
    Rheumatology International, 2008, 28 : 811 - 813
  • [28] The effect of three-dimensional computed tomography reconstructions on preoperative planning of tibial plateau fractures: a case-control series
    Dodd, Andrew
    Paolucci, Elizabeth Oddone
    Korley, Robert
    BMC MUSCULOSKELETAL DISORDERS, 2015, 16
  • [29] Evaluation of styloid process by three-dimensional computed tomography
    Basekim, CÇ
    Mutlu, H
    Güngör, A
    Silit, E
    Pekkafali, Z
    Kutlay, M
    Çolak, A
    Öztürk, E
    Kizilkaya, E
    EUROPEAN RADIOLOGY, 2005, 15 (01) : 134 - 139
  • [30] Application of three-dimensional computed tomography for the rheumatoid wrist
    Ju, Ji Hyeon
    Kang, Kwi Young
    Kim, In Je
    Yoon, Jang Uk
    Kim, Ho-Youn
    Park, Sung-Hwan
    RHEUMATOLOGY INTERNATIONAL, 2008, 28 (08) : 811 - 813