Numerical investigation on heat transfer and pressure drop of pin-fin array under the influence of rib turbulators induced vortices

被引:39
作者
Bai, Wandong [1 ]
Chen, Wei [1 ]
Yang, Li [2 ]
Chyu, Minking K. [2 ]
机构
[1] Sichuan Univ, Sch Aeronaut & Astronaut, Chengdu 610065, Sichuan, Peoples R China
[2] Univ Pittsburgh, Dept Mech Engn & Mat Sci, Pittsburgh, PA 15260 USA
关键词
Pin-fin arrays; Rib induced vortices; Entrance effect; Heat transfer performance; STAGGERED ARRAYS; CHANNELS; FLOW; RATIO;
D O I
10.1016/j.ijheatmasstransfer.2018.10.022
中图分类号
O414.1 [热力学];
学科分类号
摘要
The internal cooling systems usually consist of multiple types of structures such as ribs, pin-fins and impinging jets. The influence from upstream features could cause a significant change in performance for individual cooling technologies. The present study numerically investigated the entrance effect of rib induced vortices on pin-fin arrays' heat transfer performance. Four different rib configurations were employed in the upstream of pin-fin arrays. The flow field and heat transfer of each case were simulated by using the commercial software ANSYS CFX with the SST k-omega turbulence model. The investigation revealed that the ribs induced secondary flows significantly influenced the heat transfer distribution and flow field in pin-fin arrays, especially caused strong heat transfer variation along the spanwise direction. The presence of ribs came with enhancing heat transfer and reducing the pressure loss of pin-fin arrays. The 90 degrees rib had the best overall performance among the simulated configurations, outperforming the baseline by approximately 51%-77%. These results indicated great potential to improve pin-fin heat transfer by optimizing upstream features, and could benefit future design for the industries. (C) 2018 Elsevier Ltd. All rights reserved.
引用
收藏
页码:735 / 745
页数:11
相关论文
共 29 条
[1]  
[Anonymous], 2008, ASME TURBO EXPO, DOI DOI 10.1115/GT2008-50783
[2]  
[Anonymous], ASME HTD
[3]  
[Anonymous], TURBO EXPO POWER LAN
[4]   LENGTH TO DIAMETER RATIO AND ROW NUMBER EFFECTS IN SHORT PIN FIN HEAT-TRANSFER [J].
BRIGHAM, BA ;
VANFOSSEN, GJ .
JOURNAL OF ENGINEERING FOR GAS TURBINES AND POWER-TRANSACTIONS OF THE ASME, 1984, 106 (01) :241-245
[5]   Endwall heat transfer and pressure drop in rectangular channels with attached and detached circular pin-fin array [J].
Chang, S. W. ;
Yang, T. L. ;
Huang, C. C. ;
Chiang, K. F. .
INTERNATIONAL JOURNAL OF HEAT AND MASS TRANSFER, 2008, 51 (21-22) :5247-5259
[6]  
Chyu MK, 2007, PROCEEDINGS OF THE ASME TURBO EXPO 2007, VOL 4, PTS A AND B, P991
[7]   Recent Advances of Internal Cooling Techniques for Gas Turbine Airfoils [J].
Chyu, Minking K. ;
Siw, Sin Chien .
JOURNAL OF THERMAL SCIENCE AND ENGINEERING APPLICATIONS, 2013, 5 (02)
[8]  
Chyu MK, 2009, PROCEEDINGS OF THE ASME TURBO EXPO 2009, VOL 3, PTS A AND B, P705
[9]   INFLUENCE OF AN ARRAY OF WALL-MOUNTED CYLINDERS ON THE MASS-TRANSFER FROM A FLAT SURFACE [J].
CHYU, MK ;
GOLDSTEIN, RJ .
INTERNATIONAL JOURNAL OF HEAT AND MASS TRANSFER, 1991, 34 (09) :2175-2186
[10]   Heat transfer and pressure drop measurements in rib-roughened rectangular ducts [J].
Gao, XF ;
Sundén, B .
EXPERIMENTAL THERMAL AND FLUID SCIENCE, 2001, 24 (1-2) :25-34