Dose verification for rotating multileaf collimator IMRT

被引:0
|
作者
Schmuland, M
Otto, K
机构
[1] Univ British Columbia, Vancouver, BC V5Z 1M9, Canada
[2] British Columbia Canc Agcy, Vancouver, BC V5Z 4E6, Canada
关键词
D O I
10.1118/1.2031055
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
A new method of delivering IMRT has been proposed in which the entire MLC is rotated between each segment. Current linacs were not designed for IMRT delivery with collimator rotation and extensive quality assurance testing must be done before it can be used clinically. This work describes the different areas of testing that need to be considered, namely (1) the commissioning and QA of the Dynamic Beam Delivery (DBD) Toolbox (Varian Medical Systems, Palo Alto) required for collimator rotation control on a Varian CL21EX linac, (2) accurate fluence modeling of rotated apertures, and (3) dosimetric verification of full IMRT treatments delivered with a rotating MLC (RMLC). The DBD toolbox was tested and the collimator rotation angle was found to be accurate and reproducible to within 0.5 degrees. Fluence distributions of varying complexity were generated using the RMLC algorithm and the accuracy of the fluence modeling was validated using film based verification methods. IMRT treatment plans for a prostate, nasopharynx, and c‐shape target were generated with the RMLC segmentation algorithm and were delivered to a phantom. Measured and calculated dose distributions were compared using dose difference, distance‐to‐agreement, gamma factor maps and two‐dimensional profiles. The level of agreement was comparable to clinically accepted plans. Our results show that we can accurately control collimator rotation and precisely model fluence distributions generated from rotating MLC apertures. We also show that the RMLC technique is capable of delivering 3D clinical dose distributions accurately and reproducibly. This work was supported in part by Varian Medical Systems. © 2005, American Association of Physicists in Medicine. All rights reserved.
引用
收藏
页码:2425 / 2425
页数:1
相关论文
共 50 条
  • [31] A Multileaf Collimator for Proton Radiotherapy
    A. V. Agapov
    G. V. Mitsyn
    Biomedical Engineering, 2021, 54 : 407 - 410
  • [32] Commissioning and quality assurance in intensity modulated radiotherapy (IMRT) treatment with dynamic multileaf collimator (dMLC)
    Venencia, C
    Besa, P
    MEDICAL PHYSICS, 2003, 30 (06) : 1498 - 1498
  • [33] OPTIMIZATION OF CLINICAL DELIVERY OF IMRT TREATMENT PLANNING WITH LINACS HAVING DIFFERENT PERFORMANCE OF MULTILEAF COLLIMATOR
    Orlandini, L. C.
    Betti, M.
    De Liguoro, M.
    Pressello, M. C.
    Strigari, L.
    Luca, C.
    RADIOTHERAPY AND ONCOLOGY, 2011, 99 : S505 - S505
  • [34] Dynamic backlash of a multileaf collimator
    Kulmala, A.
    Tarvonen, J.
    Paasonen, T.
    Rintala, A.
    Koivula, L.
    Tenhunen, M.
    RADIOTHERAPY AND ONCOLOGY, 2023, 182 : S1521 - S1522
  • [35] A Multileaf Collimator for Proton Radiotherapy
    Agapov, A., V
    Mitsyn, G., V
    BIOMEDICAL ENGINEERING-MEDITSINSKAYA TEKNIKA, 2021, 54 (06): : 407 - 410
  • [36] Evaluation of Kodak EDR2 film for dose verification of intensity modulated radiation therapy delivered by a static multileaf collimator
    Zhu, XR
    Jursinic, PA
    Grimm, DF
    Lopez, F
    Rownd, JJ
    Gillin, MT
    MEDICAL PHYSICS, 2002, 29 (08) : 1687 - 1692
  • [37] MCNPX simulation of a multileaf collimator
    Pönisch, F
    Titt, U
    Kry, SF
    Vassiliev, ON
    Mohan, R
    MEDICAL PHYSICS, 2006, 33 (02) : 402 - 404
  • [38] Multileaf collimator interleaf transmission
    Balog, JP
    Mackie, TR
    Wenman, DL
    Glass, M
    Fang, G
    Pearson, D
    MEDICAL PHYSICS, 1999, 26 (02) : 176 - 186
  • [39] Dosimetric characteristics of a Multileaf Collimator
    Mubata, CD
    Bidmead, AM
    PHYSICA MEDICA, 1997, 13 (01) : 3 - 10
  • [40] CHARACTERIZATION OF A MULTILEAF COLLIMATOR SYSTEM
    GALVIN, JM
    SMITH, AR
    LALLY, B
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1993, 25 (02): : 181 - 192