Effects of sodium hypochlorite and ethylenediaminetetraacetic acid on rotary nickel-titanium instruments evaluated using atomic force microscopy

被引:39
作者
Ametrano, G. [1 ]
D'Anto, V. [1 ]
Di Caprio, M. P. [1 ]
Simeone, M. [1 ]
Rengo, S. [1 ]
Spagnuolo, G. [1 ]
机构
[1] Univ Naples Federico II, Dept Oral & Maxillofacial Sci, Naples, Italy
关键词
atomic force microscopy; EDTA; NaOCl; NiTi; ENDODONTIC INSTRUMENTS; CYCLIC FATIGUE; FRACTURE PROPERTIES; STAINLESS-STEEL; CORROSION; SURFACE; RESISTANCE; DEFECTS; TORQUE; FILES;
D O I
10.1111/j.1365-2591.2010.01799.x
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
P>Aim To use atomic force microscopy (AFM) to evaluate the effects of sodium hypochlorite (NaOCl) and ethylenediaminetetraacetic acid (EDTA) on the surface characteristics of ProTaper rotary nickel-titanium instruments. Methodology A total of twenty ProTaper (Dentsply Maillefer, Ballaigues, Switzerland) instruments (S1, S2, F1, F2) were divided into five groups: no immersion, immersion in 5.25% NaOCl for 5 or 10 min and immersion in 17% EDTA for 5 or 10 min. Twenty surface areas along 3- mm sections at the tip of the files (perfect squares of 1 x 1 mu m) were analysed by AFM operating in contact mode under ambient conditions. Three-dimensional images (400 x 400 lines) were processed using Gwyddion software, and the roughness average (Ra) and the root mean square value (RMS) of the scanned surface profiles were recorded. Data were analysed by means of anova and paired samples t-test. Results Three-dimensional AFM images of the surface of ProTaper instruments, including new and those immersed in NaOCl and EDTA solutions, revealed topographic irregularities at the nanometric scale. RMS and Ra values of instruments treated with NaOCl and EDTA solutions were statistically higher than that of the new ones (P < 0.05). Conclusions Atomic force microscopy three-dimensional images and roughness values indicated that short-term contact between NaOCl and EDTA endodontic irrigants and ProTaper instruments caused alterations in the surface of instruments.
引用
收藏
页码:203 / 209
页数:7
相关论文
共 35 条
  • [1] SEM observations of nickel-titanium rotary endodontic instruments that fractured during clinical use
    Alapati, SB
    Brantley, WA
    Svec, TA
    Powers, JM
    Nusstein, JM
    Daehn, GS
    [J]. JOURNAL OF ENDODONTICS, 2005, 31 (01) : 40 - 43
  • [2] Scanning electron microscope observations of new and used nickel-titanium rotary files
    Alapati, SB
    Brantley, WA
    Svec, TA
    Powers, JM
    Mitchell, JC
    [J]. JOURNAL OF ENDODONTICS, 2003, 29 (10) : 667 - 669
  • [3] Evaluation of single-use rotary nickel-titanium instruments
    Arens, FC
    Hoen, MM
    Steiman, HR
    Dietz, GC
    [J]. JOURNAL OF ENDODONTICS, 2003, 29 (10) : 664 - 666
  • [4] The effect of pH on the corrosion of dental metal alloys
    Bayramoglu, G
    Alemdaroglu, T
    Kedici, S
    Aksüt, AA
    [J]. JOURNAL OF ORAL REHABILITATION, 2000, 27 (07) : 563 - 575
  • [5] Influence of sodium hypochlorite on fracture properties and corrosion of ProTaper Rotary instruments
    Berutti, E.
    Angelini, E.
    Rigolone, M.
    Migliaretti, G.
    Pasqualini, D.
    [J]. INTERNATIONAL ENDODONTIC JOURNAL, 2006, 39 (09) : 693 - 699
  • [6] Pitting corrosion resistance of nickel-titanium rotary instruments with different surface treatments in seventeen percent ethylenediaminetetraacetic acid and sodium chloride solutions
    Bonaccorso, Antonio
    Tripi, Teresa Roberta
    Rondelli, Gianni
    Condorelli, Guglielmo Guido
    Cantatore, Giuseppe
    Schaefer, Edgar
    [J]. JOURNAL OF ENDODONTICS, 2008, 34 (02) : 208 - 211
  • [7] Busslinger A, 1998, INT ENDOD J, V31, P290
  • [8] Time-dependent effects of EDTA on dentin structures
    Çalt, S
    Serper, A
    [J]. JOURNAL OF ENDODONTICS, 2002, 28 (01) : 17 - 19
  • [9] Cavalleri G, 2009, Minerva Stomatol, V58, P225
  • [10] Recent developments and new strategies in scanning electron microscopy
    Cazaux, J
    [J]. JOURNAL OF MICROSCOPY, 2005, 217 : 16 - 35