A Case Study on 500 kV Line Performance Related to Lightning in Malaysia

被引:15
|
作者
Rawi, Iryani Mohamed [1 ,2 ]
Ab Kadir, Mohd Zainal Abidin [3 ]
Gomes, Chandima [3 ]
Azis, Norhafiz [3 ]
机构
[1] Tenaga Nas Berhad, Engn Dept, TNB Transmiss Div, Kuala Lumpur 50470, Malaysia
[2] Univ Putra Malaysia, Serdang 43400, Malaysia
[3] Univ Putra Malaysia, Fac Engn, Serdang 43400, Malaysia
关键词
Ground flash density (GFD); lightning detection network (LDN); lightning; monsoon; overhead lines; statistics; tower footing resistance (TFR); VOLTAGE TRANSMISSION-LINES; OUTAGES;
D O I
10.1109/TPWRD.2017.2787660
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
Lightning-related outages are of great concern for power utility companies especially in the tropical regions. Tenaga Nasional Berhad as the system operator in Malaysia realized the importance of this issue. In this paper, statistical information on transmission line outages, together with lightning stroke data, are presented. Lightning data were obtained from TNB Lightning Detection Network which generates lightning density map and other information, such as peak current, polarity, and location of the detected strokes with 500-m location accuracy. A case study on the 500 kV A-to-B line represents statistical information of collected strokes where 18 kA and 14 kA were reported as median values of current peak for negative and positive strokes, respectively. Mean values are 22 kA for negative strokes and 17 kA for positive strokes. About 93% of 658 619 collected strokes from 2004 to 2015 are negative whereas the remaining are positive. A total of 582 (90%) negative strokes and 65 (10%) positive strokes were recorded along a selected case line where 83% of outages were reported to occur on the top phase. Lightning stroke density, terrain characteristics, tower footing resistance, and monsoon activities were highlighted as contributing factors on line performance due to lightning in this study.
引用
收藏
页码:2180 / 2186
页数:7
相关论文
共 50 条
  • [21] Lightning performance of quadruple circuit transmission line with Voltage 500 kV on the same vertical tower under unbalance insulation
    Su, Fei
    Zhou, Hao
    Zhao, Bincai
    Gaodianya Jishu/High Voltage Engineering, 2012, 38 (09): : 2473 - 2480
  • [22] Research on Lightning Performance of Quadruple Circuit Transmission Line with Dual Voltage 500/220-kV on the Same Tower
    Li Xiaolan
    Du Zhongdong
    Wen Jiqun
    Chen Jiahong
    Gu Shanqiang
    2011 ASIA-PACIFIC POWER AND ENERGY ENGINEERING CONFERENCE (APPEEC), 2011,
  • [23] Studying of Lightning Surge Transient Effect on 500 kV Quadruple Circuit Transmission Line
    Kusuma, Aristo Adi
    Pramana, Putu Agus Aditya
    Munir, Buyung S.
    Ayu, Rica S.
    2016 6TH INTERNATIONAL ANNUAL ENGINEERING SEMINAR (INAES), 2016, : 276 - 279
  • [24] Lightning Backflash Performance for ±500kV Double Circuit Transmission Lines
    Lu, Hailiang
    Wen, Xishan
    Zhang, Chengwei
    Tong, Xuefang
    2009 ASIA-PACIFIC POWER AND ENERGY ENGINEERING CONFERENCE (APPEEC), VOLS 1-7, 2009, : 3535 - +
  • [25] Lightning Performance Assessment of 500kV Transmission Lines in Southern China
    Zhao, Xiangen
    Xie, Yaoheng
    He, Hengxin
    He, Junjia
    Chen, Xipeng
    Cai, Hansheng
    2013 IEEE POWER AND ENERGY SOCIETY GENERAL MEETING (PES), 2013,
  • [26] Investigation on the 132kV overhead lines lightning-related flashovers in Malaysia
    Rawi, Iryani Mohamed
    Ab Kadir, Mohd Zainal Abidin
    2015 INTERNATIONAL SYMPOSIUM ON LIGHTNING PROTECTION (XIII SIPDA), 2015, : 239 - 243
  • [27] The Lightning Shielding Effect to ±1100 kV UHVDC Line Provided by a Parallel 500kV AC Line in a Joint Right-of-Way
    Sun, Zezhong
    Lan, Lei
    Zhu, Changcheng
    2018 34TH INTERNATIONAL CONFERENCE ON LIGHTNING PROTECTION (ICLP 2018), 2018,
  • [28] Observation of Lightning Overvoltage in a 500 kV Switching Station
    Sonoda, Toshio
    Morii, Hiroshi
    Sekioka, Shozo
    IEEE TRANSACTIONS ON POWER DELIVERY, 2017, 32 (04) : 1828 - 1834
  • [29] Analysis on lightning overvoltage of 500kV substation
    Shao Yu
    Shao Ming
    Shi Feng
    Wang Kun
    MECHATRONICS, ROBOTICS AND AUTOMATION, PTS 1-3, 2013, 373-375 : 1541 - 1545
  • [30] Lightning back flashover tripping patterns on a 275/132 kV quadruple circuit transmission line in Malaysia
    Abd Halim, Syahirah
    Abu Bakar, Ab Halim
    Illias, Hazlee Azil
    Hassan, Nor Hidayah Nor
    Mokhlis, Hazlee
    Terzija, Vladimir
    IET SCIENCE MEASUREMENT & TECHNOLOGY, 2016, 10 (04) : 344 - 354