Accurate modeling of single-particle cryo-EM images quantitates the benefits expected from using Zernike phase contrast

被引:22
作者
Hall, R. J. [1 ]
Nogales, E. [1 ,2 ,3 ]
Glaeser, R. M. [1 ,3 ]
机构
[1] Univ Calif Berkeley, Inst QB3, Berkeley, CA 94720 USA
[2] Univ Calif Berkeley, Howard Hughes Med Inst, Berkeley, CA 94720 USA
[3] Univ Calif Berkeley, Lawrence Berkeley Lab, Div Life Sci, Berkeley, CA 94720 USA
关键词
Zernike phase contrast; Cryo-electron microscopy; Multislice; Image simulation; Heterogeneity; RESOLUTION ELECTRON-MICROSCOPY; TOBACCO-MOSAIC-VIRUS; CRYOELECTRON MICROSCOPY; MACROMOLECULES; CLASSIFICATION; RECONSTRUCTION; SIMULATION; DYNAMICS; SPACE; PLATE;
D O I
10.1016/j.jsb.2011.03.020
中图分类号
Q5 [生物化学]; Q7 [分子生物学];
学科分类号
071010 ; 081704 ;
摘要
The use of a Zernike-type phase plate in biological cryo-electron microscopy allows the imaging, without using defocus, of what are predominantly phase objects. It is thought that such phase-plate implementations might result in higher quality images, free from the problems of CTF correction that occur when images must be recorded at extremely high values of defocus. In single-particle cryo-electron microscopy it is hoped that these improvements in image quality will facilitate work on structures that have proved difficult to study, either because of their relatively small size or because the structures are not completely homogeneous. There is still a need, however, to quantitate how much improvement can be gained by using a phase plate for single-particle cryo-electron microscopy. We present a method for quantitatively modeling the images recorded with 200 keV electrons, for single particles embedded in vitreous ice. We then investigate what difference the use of a phase-plate device could have on the processing of single-particle data. We confirm that using a phase plate results in single-particle datasets in which smaller molecules can be detected, particles can be more accurately aligned and problems of heterogeneity can be more easily addressed. (C) 2011 Elsevier Inc. All rights reserved.
引用
收藏
页码:468 / 475
页数:8
相关论文
共 32 条
  • [1] [Anonymous], 2008, Introduction to Fourier optics
  • [2] PROTEIN DATA BANK - COMPUTER-BASED ARCHIVAL FILE FOR MACROMOLECULAR STRUCTURES
    BERNSTEIN, FC
    KOETZLE, TF
    WILLIAMS, GJB
    MEYER, EF
    BRICE, MD
    RODGERS, JR
    KENNARD, O
    SHIMANOUCHI, T
    TASUMI, M
    [J]. JOURNAL OF MOLECULAR BIOLOGY, 1977, 112 (03) : 535 - 542
  • [3] BOERSCH H, 1947, Z NATURFORSCH A, V2, P615
  • [4] Design of a microfabricated, two-electrode phase-contrast element suitable for electron microscopy
    Cambie, Rossana
    Downing, Kenneth H.
    Typke, Dieter
    Glaeser, Robert M.
    Jin, Jian
    [J]. ULTRAMICROSCOPY, 2007, 107 (4-5) : 329 - 339
  • [5] Zernike Phase Plate Cryoelectron Microscopy Facilitates Single Particle Analysis of Unstained Asymmetric Protein Complexes
    Chang, Wei-Hau
    Chiu, Michael T. -K.
    Chen, Chin-Yu
    Yen, Chi-Fu
    Lin, Yen-Cheng
    Weng, Yi-Ping
    Chang, Ji-Chau
    Wu, Yi-Min
    Cheng, Holland
    Fu, Jianhua
    Tu, I-Ping
    [J]. STRUCTURE, 2010, 18 (01) : 17 - 27
  • [6] Practical factors affecting the performance of a thin-film phase plate for transmission electron microscopy
    Danev, Radostin
    Glaeser, Robert M.
    Nagayama, Kuniaki
    [J]. ULTRAMICROSCOPY, 2009, 109 (04) : 312 - 325
  • [7] Frank J., 2006, Three-dimensional electron microscopy of macromolecular assemblies: visualization of biological molecules in their native state
  • [8] Unsupervised classification of single particles by cluster tracking in multi-dimensional space
    Fu, Jie
    Gao, Haixiao
    Frank, Joachim
    [J]. JOURNAL OF STRUCTURAL BIOLOGY, 2007, 157 (01) : 226 - 239
  • [9] Study of the structural dynamics of the E-coli 70S ribosome using real-space refinement
    Gao, HX
    Sengupta, J
    Valle, M
    Korostelev, A
    Eswar, N
    Stagg, SM
    Van Roey, P
    Agrawal, RK
    Harvey, SC
    Sali, A
    Chapman, MS
    Frank, J
    [J]. CELL, 2003, 113 (06) : 789 - 801
  • [10] Glaeser R M., 2007, ELECT CRYSTALLOGRAPH, DOI DOI 10.1038/nsb891