COMPARISON OF RADIATION DOSE AND IMAGE QUALITY IN HEAD CT SCANS AMONG MULTIDETECTOR CT SCANNERS

被引:3
作者
Abuzaid, Mohamed M. [1 ]
Elshami, Wiam [1 ]
Tekin, H. O. [1 ]
Sulieman, Abdelmoneim [2 ]
Bradley, D. A. [3 ,4 ]
机构
[1] Univ Sharjah, Coll Hlth Sci, Med Diagnost Imaging Dept, Sharjah, U Arab Emirates
[2] Prince Sattam Bin Abdulaziz Univ, Coll Appl Med Sci, Radiol & Med Imaging Dept, Alkharj, Saudi Arabia
[3] Sunway Univ, Ctr Appl Phys & Radiat Technol, Jalan Univ, Pj 46150, Malaysia
[4] Univ Surery, Dept Phys, Guildford GU2 7XH, Surrey, England
关键词
COMPUTED-TOMOGRAPHY; 64-MDCT; OPTIMIZATION; PROTOCOLS; ADULT;
D O I
10.1093/rpd/ncab125
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
The present study compares three different multidetector CT (MDCT) scanners for routine brain imaging in terms of image quality and radiation doses. The volume CT dose index (CTDIvol), dose-length product (DLP), and effective dose (E) were calculated. Subjective image assessment was obtained based on a scale ranging from 1 (unacceptable) to 5 (optimum). All images scored 3.5 or over, with the 160-slice MDCT images being favoured. For the 4-, 16- and 160-slice MDCT scanners, the respective median values for CTDIvol were 57 mGy, 41 mGy, and 28 mGy; DLP values were 901 mGy.cm, 680 mGy.cm, and 551 mGy.cm; and effective doses were 2 mSv, 1.5 mSv, and 1 mSv, respectively. Compared to the 160-slice MDCT, the dose values for the 4- and 16-slice units were significantly greater. In practice, the CT modality used must be carefully selected to avoid elevated radiation doses and maintain image quality.
引用
收藏
页码:10 / 16
页数:7
相关论文
共 35 条
[31]  
Shefer E., 2013, CURR RADIOL REP, V1, P76, DOI [10.1007/s40134-012-0006-4, DOI 10.1007/S40134-012-0006-4]
[32]   Comparison of Eye Lens Dose on Neuroimaging Protocols between 16-and 64-Section Multidetector CT: Achieving the Lowest Possible Dose [J].
Tan, J. S. P. ;
Tan, K. -L. ;
Lee, J. C. L. ;
Wan, C. -M. ;
Leong, J. -L. ;
Chan, L. -L. .
AMERICAN JOURNAL OF NEURORADIOLOGY, 2009, 30 (02) :373-377
[33]   Radiation Exposure and Health Effects - is it Time to Reassess the Real Consequences? [J].
Thomas, G. A. ;
Symonds, P. .
CLINICAL ONCOLOGY, 2016, 28 (04) :231-236
[34]   Standardization and Optimization of CT Protocols to Achieve Low Dose [J].
Trattner, Sigal ;
Pearson, Gregory D. N. ;
Chin, Cynthia ;
Cody, Dianna D. ;
Gupta, Rajiv ;
Hess, Christopher P. ;
Kalra, Mannudeep K. ;
Kofler, James M., Jr. ;
Krishnann, Mayil S. ;
Einstein, Andrew J. .
JOURNAL OF THE AMERICAN COLLEGE OF RADIOLOGY, 2014, 11 (03) :271-278
[35]   Subjective and objective comparisons of image quality between ultra-high-resolution CT and conventional area detector CT in phantoms and cadaveric human lungs [J].
Yanagawa, Masahiro ;
Hata, Akinori ;
Honda, Osamu ;
Kikuchi, Noriko ;
Miyata, Tomo ;
Uranishi, Ayumi ;
Tsukagoshi, Shinsuke ;
Tomiyama, Noriyuki .
EUROPEAN RADIOLOGY, 2018, 28 (12) :5060-5068