Fracture of a spline of the femoral stem in an ingrown modular hip implant

被引:3
作者
McNabb, David Clinton [1 ,2 ]
Jennings, Jason M. [1 ]
Dennis, Douglas A. [1 ,3 ,4 ,5 ]
机构
[1] Colorado Joint Replacement, 2535 S Downing St,Suite 100, Denver, CO 80210 USA
[2] Raleigh Orthopaed Clin, Raleigh, NC USA
[3] Univ Denver, Dept Biomed Engn, Denver, CO USA
[4] Univ Tennessee, Dept Biomed Engn, Knoxville, TN USA
[5] Univ Colorado, Hlth Sch Med, Dept Orthopaed, Aurora, CO USA
关键词
Hip arthroplasty; Modularity; Stem fracture; SLEEVE INTERFACE; ARTHROPLASTY;
D O I
10.5301/hipint.5000399
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Introduction: Physiologic strain patterns of the femur are altered by the bending stiffness of the implant as well as the loading pattern of the implant itself. The Savish Range of Motion (S-ROM) femoral stem has been designed with flutes (to decrease distal material) and with a coronal slot (to decrease stiffness). Materials: The purpose of this case report is to briefly discuss design characteristics of femoral stems and their relationship to thigh pain as well as to describe the only report in the literature of a fracture of the anterior spline of a S-ROM prosthesis at the coronal slot. Results: The femoral stem fractured at the coronal slot due to multiple bending moments in a small diameter stem. Conclusions: The proximal metaphyseal sleeve remains well fixed and the patient is functioning well without pain nearly a year after the identification of the fracture on routine follow-up.
引用
收藏
页码:E35 / E38
页数:4
相关论文
共 15 条
  • [1] Brown Thomas E, 2002, J Am Acad Orthop Surg, V10, P385
  • [2] Fractures of distally-fixed femoral stems after revision arthroplasty
    Busch, CA
    Charles, MN
    Bourne, RB
    Rorabeck, CH
    MacDonald, SJ
    McCalden, RW
    [J]. JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 2005, 87B (10): : 1333 - 1336
  • [3] Cameron H U, 1993, J Arthroplasty, V8, P239, DOI 10.1016/S0883-5403(06)80084-7
  • [4] HEAD WC, 1995, CLIN ORTHOP RELAT R, P85
  • [5] Cementless Femoral Fixation in Total Hip Arthroplasty
    Khanuja, Harpal S.
    Vakil, Jeffrey J.
    Goddard, Maria S.
    Mont, Michael A.
    [J]. JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2011, 93A (05) : 500 - 509
  • [6] Proximal Component Modularity in THA-At What Cost?: An Implant Retrieval Study
    Kop, A. M.
    Keogh, C.
    Swarts, E.
    [J]. CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 2012, 470 (07) : 1885 - 1894
  • [7] Landa J, 2009, J ARTHROPLASTY, V24
  • [8] Modular Femoral Sleeve and Stem Implant Provides Long-term Total Hip Survivorship
    Le, David
    Smith, Karen
    Tanzer, Dylan
    Tanzer, Michael
    [J]. CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 2011, 469 (02) : 508 - 513
  • [9] Failure of a Modular Hip Implant at the Stem-Sleeve Interface
    Mehran, Nima
    North, Trevor
    Laker, Michael
    [J]. ORTHOPEDICS, 2013, 36 (07) : E978 - E981
  • [10] Namba RS, 1998, CLIN ORTHOP RELAT R, P261