A model-based controller for a three-phase four-wire shunt active filter with compensation of the neutral line current

被引:34
作者
Escobar, Gerardo [1 ]
Valdez, Andres A. [1 ]
Torres-Guin, Raymundo E. [1 ]
Martinez-Montejano, Misael F. [1 ]
机构
[1] IPICYT, Lab Proc & Qual Energy, Luis Potos 78216, Mexico
关键词
active filters; adaptive signal detection; reactive power control;
D O I
10.1109/TPEL.2007.909297
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
This paper presents a model-based controller for a three-phase four-wire shunt active filter, which uses a three-leg split-capacitor topology to implement the voltage source inverter. The controller is aimed to compensate reactive power and harmonic distortion in the general case of distorted and unbalanced source voltages and load currents, including distorted loads connected between a phase and the neutral line. In addition, the controller is able to compensate for the homopolar component of the load current, that is, the current flowing to the source via the neutral line can be considerably reduced without modifying the actual topology. The complete model in (fixed frame) alpha beta gamma-coordinates is presented. Special attention is given to the homopolar component (referred here as the gamma-component) of the line current, source voltage and control input, which are instrumental for the control design purpose. Experimental results in a 2 kVA prototype are provided to illustrate the benefits of the proposed solution.
引用
收藏
页码:2261 / 2270
页数:10
相关论文
共 23 条
  • [1] AKAGI H, 1998, IEEE T POWER ELECTR, V13, P1174
  • [2] Three-phase four-wire shunt active filter control strategies
    Aredes, M
    Hafner, J
    Heumann, K
    [J]. IEEE TRANSACTIONS ON POWER ELECTRONICS, 1997, 12 (02) : 311 - 318
  • [3] A theoretical investigation of original and modified instantaneous power theory applied to four-wire systems
    Depenbrck, M
    Staudt, V
    Wrede, H
    [J]. IEEE TRANSACTIONS ON INDUSTRY APPLICATIONS, 2003, 39 (04) : 1160 - 1168
  • [4] An adaptive controller in stationary reference frame for D-Statcom in unbalanced operation
    Escobar, G
    Stankovic, AM
    Mattavelli, P
    [J]. IEEE TRANSACTIONS ON INDUSTRIAL ELECTRONICS, 2004, 51 (02) : 401 - 409
  • [5] A single synchronous frame hybrid (SSFH) multifrequency controller for power active filters
    Etxeberria-Otadui, Ion
    Lopez de Heredia, Amaia
    Gaztanaga, Haizea
    Bacha, Seddik
    Reyero, Raul
    [J]. IEEE TRANSACTIONS ON INDUSTRIAL ELECTRONICS, 2006, 53 (05) : 1640 - 1648
  • [6] INTERNAL MODEL PRINCIPLE FOR LINEAR-MULTIVARIABLE REGULATORS
    FRANCIS, BA
    WONHAM, WM
    [J]. APPLIED MATHEMATICS AND OPTIMIZATION, 1975, 2 (02) : 170 - 194
  • [7] FUKUDA S, 1999, P EUR POW EL C EPE L
  • [8] FUKUDA S, 2000, P 35 IAS ANN M ROM O
  • [9] Jacobina CB, 2000, IEEE POWER ELECTRON, P767, DOI 10.1109/PESC.2000.879912
  • [10] Khalil H. K., 2002, NONLINEAR SYSTEMS, V3