Three-dimensional vascular and metabolic imaging using inverted autofluorescence

被引:7
|
作者
Mehrvar, Shima [1 ]
Mostaghimi, Soudeh [1 ]
Camara, Amadou K. [2 ,3 ]
Foomani, Farnaz [1 ]
Narayanan, Jayashree [2 ,4 ]
Fish, Brian [2 ,4 ]
Medhora, Meetha [2 ,4 ]
Ranji, Mahsa [5 ]
机构
[1] Univ Wisconsin, Dept Elect Engn, Biophoton Lab, Milwaukee, WI 53201 USA
[2] Med Coll Wisconsin, Dept Physiol, 8701 Watertown Plank Rd, Milwaukee, WI 53226 USA
[3] Med Coll Wisconsin, Cardiovasc Res Ctr, Dept Anesthesiol, Milwaukee, WI 53226 USA
[4] Med Coll Wisconsin, Cardiovasc Res Ctr, Dept Radiat Oncol, Milwaukee, WI 53226 USA
[5] Florida Atlantic Univ, Dept Comp & Elect Engn & Comp Sci, Boca Raton, FL 33431 USA
关键词
vascular imaging; three-dimensional vessel network; label-free; fluorescence imaging; NADH; whole organ; MITOCHONDRIAL REDOX STATE; FLUORESCENCE; IRRADIATION; CANCER; MODEL; TRANSGENESIS; RESOLUTION; NETWORKS; RODENTS; INJURY;
D O I
10.1117/1.JBO.26.7.076002
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Significance: Three-dimensional (3D) vascular and metabolic imaging (VMI) of whole organs in rodents provides critical and important (patho)physiological information in studying animal models of vascular network. Aim: Autofluorescence metabolic imaging has been used to evaluate mitochondrial metabolites such as nicotinamide adenine dinucleotide (NADH) and flavine adenine dinucleotide (FAD). Leveraging these autofluorescence images of whole organs of rodents, we have developed a 3D vascular segmentation technique to delineate the anatomy of the vasculature as well as mitochondrial metabolic distribution. Approach: By measuring fluorescence from naturally occurring mitochondrial metabolites combined with light-absorbing properties of hemoglobin, we detected the 3D structure of the vascular tree of rodent lungs, kidneys, hearts, and livers using VMI. For lung VMI, an exogenous fluorescent dye was injected into the trachea for inflation and to separate the airways, confirming no overlap between the segmented vessels and airways. Results: The kidney vasculature from genetically engineered rats expressing endothelial-specific red fluorescent protein TdTomato confirmed a significant overlap with VMI. This approach abided by the "minimum work" hypothesis of the vascular network fitting to Murray's law. Finally, the vascular segmentation approach confirmed the vascular regression in rats, induced by ionizing radiation. Conclusions: Simultaneous vascular and metabolic information extracted from the VMI provides quantitative diagnostic markers without the confounding effects of vascular stains, fillers, or contrast agents. (C) The Authors. Published by SPIE under a Creative Commons Attribution 4.0 Unported License.
引用
收藏
页数:16
相关论文
共 50 条
  • [31] Luminescence lifetime imaging of three-dimensional biological objects
    Dmitriev, Ruslan, I
    Intes, Xavier
    Barroso, Margarida M.
    JOURNAL OF CELL SCIENCE, 2021, 134 (09)
  • [32] Synthetic aperture diffraction tomography for three-dimensional imaging
    Simonetti, Francesco
    Huang, Lianjie
    PROCEEDINGS OF THE ROYAL SOCIETY A-MATHEMATICAL PHYSICAL AND ENGINEERING SCIENCES, 2009, 465 (2109): : 2877 - 2895
  • [33] Three-Dimensional Magnetic Resonance Imaging in the Musculoskeletal System
    Ahlawat, Shivani
    Kumar, Neil M.
    Ghasemi, Ali
    Fayad, Laura M.
    INVESTIGATIVE RADIOLOGY, 2025, 60 (03) : 184 - 197
  • [34] Three-dimensional ultrasonic Nakagami imaging for tissue characterization
    Tsui, Po-Hsiang
    Hsu, Cheng-Wei
    Ho, Ming-Chih
    Chen, Yung-Sheng
    Lin, Jen-Jen
    Chang, Chien-Cheng
    Chu, Chin-Chou
    PHYSICS IN MEDICINE AND BIOLOGY, 2010, 55 (19) : 5849 - 5866
  • [35] Three-dimensional fluorescence imaging based on digital holography
    Matoba, Osamu
    Quan, Xiangyu
    Awatsuji, Yasuhiro
    2017 16TH WORKSHOP ON INFORMATION OPTICS (WIO), 2017,
  • [36] Differential diagnosis of lung carcinoma with three-dimensional quantitative molecular vibrational imaging
    Gao, Liang
    Hammoudi, Ahmad A.
    Li, Fuhai
    Thrall, Michael J.
    Cagle, Philip T.
    Chen, Yuanxin
    Yang, Jian
    Xia, Xiaofeng
    Fan, Yubo
    Massoud, Yehia
    Wang, Zhiyong
    Wong, Stephen T. C.
    JOURNAL OF BIOMEDICAL OPTICS, 2012, 17 (06)
  • [37] Three-dimensional imaging through scattering media based on confocal diffuse tomography
    Lindell, David B.
    Wetzstein, Gordon
    NATURE COMMUNICATIONS, 2020, 11 (01)
  • [38] Three-Dimensional Characterization of the Vascular Bed in Bone Metastasis of the Rat by Microcomputed Tomography (MicroCT)
    Nyangoga, Herve
    Mercier, Philippe
    Libouban, Helene
    Basle, Michel Felix
    Chappard, Daniel
    PLOS ONE, 2011, 6 (03):
  • [39] The reinvention of twentieth century microscopy for three-dimensional imaging
    Whitehead, Lachlan W.
    McArthur, Kate
    Geoghegan, Niall D.
    Rogers, Kelly L.
    IMMUNOLOGY AND CELL BIOLOGY, 2017, 95 (06) : 520 - 524
  • [40] Three-dimensional MR Fingerprinting for Quantitative Breast Imaging
    Chen, Yong
    Panda, Ananya
    Pahwa, Shivani
    Hamilton, Jesse I.
    Dastmalchian, Sara
    McGivney, Debra F.
    Ma, Dan
    Batesole, Joshua
    Seiberlich, Nicole
    Griswold, Mark A.
    Plecha, Donna
    Gulani, Vikas
    RADIOLOGY, 2019, 290 (01) : 33 - 40