The Impact of the Electric Double-Layer Capacitor (EDLC) in Reducing Stress and Improving Battery Lifespan in a Hybrid Energy Storage System (HESS) System

被引:12
作者
Tshiani, Chrispin Tumba [1 ]
Umenne, Patrice [1 ]
机构
[1] Univ South Africa, Elect Engn Dept, ZA-1709 Johannesburg, South Africa
关键词
battery lifespan; battery energy storage system (BESS); EDLC; hybrid energy storage system (HESS); !text type='Python']Python[!/text; MATLAB; Simulink (PMS)-hybrid model; supercapacitor; DESIGN;
D O I
10.3390/en15228680
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
This paper investigates the effect of the electric double layer capacitor (EDLC) in reducing stress and prolonging the battery lifespan in a hybrid energy storage system (HESS). A 65 F, 16.2 V EDLC supercapacitor was connected in a laboratory experiment to produce its charge/discharge profile at a constant current of 5 and 10 A. The EDLC's Faranda or "two branch model" mathematical parameters were extracted from the experimental charge/discharge profile. The extracted parameters were used as inputs to design the Python/MATLAB/Simulink (PMS)-hybrid model of the EDLC. The charge/discharge profiles of the simulated PMS model of the EDLC were then compared to the charge/discharge profiles derived from the experimental setup of the EDLC and were found to match. The PMS model of the EDLC was then used as a subcomponent in an HESS system modelled in MATLAB/Simulink. Using constant load conditions, the battery's voltage, current, power and state of charge (SOC) were analyzed for a battery energy storage system (BESS) without a supercapacitor and then compared to an HESS system with a supercapacitor in an experimental setup. This process was repeated with the simulated PMS model of the EDLC in MATLAB/Simulink for HESS and without the EDLC for BESS. Finally using a variable load in an experimental setup, the battery's voltage and current were analyzed for a BESS system and compared to an HESS system. All these data show that, in an HESS system with a supercapacitor, there is less stress on the battery with a load applied. This is indicated by the voltage and current values in an HESS system being consistently more stable with respect to time as compared to the BESS system. As a result, in an HESS system, the battery will have a longer lifespan.
引用
收藏
页数:19
相关论文
共 23 条
  • [1] Argyrou Maria C., 2018, 2018 53 INT U POWER
  • [2] Impact of Power Sharing Method on Battery Life Extension in HESS for Grid Ancillary Services
    Bahloul, Mohamed
    Khadem, Shafiuzzaman K.
    [J]. IEEE TRANSACTIONS ON ENERGY CONVERSION, 2019, 34 (03) : 1317 - 1327
  • [3] Optimal Design of a Hybrid Energy Storage System in a Plug-In Hybrid Electric Vehicle for Battery Lifetime Improvement
    Bai, Yunfei
    Li, Jianwei
    He, Hongwen
    Dos Santos, Ricardo Caneloi
    Yang, Qingqing
    [J]. IEEE ACCESS, 2020, 8 : 142148 - 142158
  • [4] Camara M.A., 2013, Int. J. Renew. Sustain. Energy, V2, P222, DOI [10.11648/j.ijrse.20130206.16, DOI 10.11648/J.IJRSE.20130206.16]
  • [5] Danila E., 2010, PAPER PRESENTED 3 IN
  • [6] Dey J.P.V., 2019, P 381 2019 IEEE 5 IN, P1
  • [7] Faranda R., 2007, IEEE International Conference on Clean Electrical Power, 2007. ICCEP '07, P706
  • [8] Gee A.M., 2010, 45 INT U POW ENG C U, P1
  • [9] Hybrid energy storage system for microgrids applications: A review
    Hajiaghasi, Salman
    Salemnia, Ahmad
    Hamzeh, Mohsen
    [J]. JOURNAL OF ENERGY STORAGE, 2019, 21 : 543 - 570
  • [10] Battery-supercapacitor hybrid energy storage system in standalone DC microgrids: areview
    Jing, Wenlong
    Lai, Chean Hung
    Wong, Shung Hui Wallace
    Wong, Mou Ling Dennis
    [J]. IET RENEWABLE POWER GENERATION, 2017, 11 (04) : 461 - 469