A novel method for measuring absolute coronary blood flow and microvascular resistance in patients with ischaemic heart disease

被引:34
作者
Morris, Paul D. [1 ,2 ,3 ]
Gosling, Rebecca [1 ,2 ,3 ]
Zwierzak, Iwona [1 ,3 ]
Evans, Holli [1 ]
Aubiniere-Robb, Louise [1 ]
Czechowicz, Krzysztof [1 ]
Evans, Paul C. [1 ,3 ,4 ]
Hose, D. Rodney [1 ,3 ,5 ]
Lawford, Patricia, V [1 ,3 ]
Narracott, Andrew J. [1 ,3 ]
Gunn, Julian P. [1 ,2 ,3 ]
机构
[1] Univ Sheffield, Med Sch, Dept Infect Immun & Cardiovasc Dis, Math Modelling Med Grp, Sheffield, S Yorkshire, England
[2] Sheffield Teaching Hosp NHS Fdn Trust, Dept Cardiol, Sheffield, S Yorkshire, England
[3] Univ Sheffield, Insigneo Inst Silico Med, Sheffield, S Yorkshire, England
[4] Univ Sheffield, Bateson Ctr, Sheffield, S Yorkshire, England
[5] Norwegian Univ Sci & Technol NTNU, Dept Circulat & Med Imaging, Trondheim, Norway
基金
英国惠康基金; 英国医学研究理事会;
关键词
Coronary blood flow; Computational fluid dynamics; Coronary physiology; Coronary angiography; Coronary microvascular dysfunction; SUBSELECTIVE MEASUREMENT; CARDIAC-CATHETERIZATION; DIAGNOSTIC-ACCURACY; MEDICAL THERAPY; ARTERY-DISEASE; RESERVE; VELOCITY; PRESSURE; DYSFUNCTION; RISK;
D O I
10.1093/cvr/cvaa220
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Aims Ischaemic heart disease is the reduction of myocardial blood flow, caused by epicardial and/or microvascular disease. Both are common and prognostically important conditions, with distinct guideline-indicated management. Fractional flow reserve (FFR) is the current gold-standard assessment of epicardial coronary disease but is only a surrogate of flow and only predicts percentage flow changes. It cannot assess absolute (volumetric) flow or microvascular disease. The aim of this study was to develop and validate a novel method that predicts absolute coronary blood flow and microvascular resistance (MVR) in the catheter laboratory. Methods and results A computational fluid dynamics (CFD) model was used to predict absolute coronary flow (Q(CFD)) and coronary MVR using data from routine invasive angiography and pressure-wire assessment. Q(CFD) was validated in an in vitro flow circuit which incorporated patient-specific, three-dimensional printed coronary arteries; and then in vivo, in patients with coronary disease. In vitro, QCFD agreed closely with the experimental flow over all flow rates [bias +2.08 mL/min; 95% confidence interval (error range) -4.7 to +8.8 mL/min; R-2 = 0.999, P < 0.001; variability coefficient <1%]. In vivo, Q(CFD) and MVR were successfully computed in all 40 patients under baseline and hyperaemic conditions, from which coronary flow reserve (CFR) was also calculated. Q(CFD)-derived CFR correlated closely with pressure-derived CFR (R-2 = 0.92, P < 0.001). This novel method was significantly more accurate than Doppler-wire-derived flow both in vitro (+/- 6.7 vs. +/- 34 mL/min) and in vivo (+/- 0.9 vs. +/- 24.4 mmHg). Conclusions Absolute coronary flow and MVR can be determined alongside FFR, in absolute units, during routine catheter laboratory assessment, without the need for additional catheters, wires or drug infusions. Using this novel method, epicardial and microvascular disease can be discriminated and quantified. This comprehensive coronary physiological assessment may enable a new level of patient stratification and management. [GRAPHICS] .
引用
收藏
页码:1567 / 1577
页数:11
相关论文
共 50 条
  • [21] Impact of hyperaemic microvascular resistance on fractional flow reserve measurements in patients with stable coronary artery disease: insights from combined stenosis and microvascular resistance assessment
    van de Hoef, Tim P.
    Nolte, Froukje
    Echavarria-Pinto, Mauro
    van Lavieren, Martijn A.
    Damman, Peter
    Chamuleau, Steven A. J.
    Voskuil, Michiel
    Verberne, Hein J.
    Henriques, Jose P. S.
    van Eck-Smit, Berthe L. F.
    Koch, Karel T.
    de Winter, Robbert J.
    Spaan, Jos A. E.
    Siebes, Maria
    Tijssen, Jan G. P.
    Meuwissen, Martijn
    Piek, Jan J.
    HEART, 2014, 100 (12) : 951 - 959
  • [22] Continuous thermodilution- a novel method for direct measurement of coronary flow and resistance
    Kala, Petr
    Adlova, Radka
    Gasparkova, Veronika
    Ostadal, Petr
    Hajek, Petr
    COR ET VASA, 2025, 67 (01) : 35 - 42
  • [23] Assessment of aspirin resistance varies on a temporal basis in patients with ischaemic heart disease
    Muir, A. R.
    McMullin, M. F.
    Patterson, C.
    McKeown, P. P.
    HEART, 2009, 95 (15) : 1225 - 1229
  • [24] Basal Coronary Microvascular Resistance Predicting Death and Heart Failure in Patients Without Functional Coronary Stenosis
    Murai, Tadashi
    Hikita, Hiroyuki
    Yamaguchi, Masao
    Ito, Aki
    Warisawa, Takayuki
    Ikeda, Hiroshi
    Takahashi, Ken
    Yano, Hirotaka
    Chang, Joonmo
    Watanabe, Takahiro
    Yoshikawa, Hiroshi
    Kanno, Yoshinori
    Hishikari, Keiichi
    Takahashi, Atsushi
    Fujii, Hiroyuki
    Yonetsu, Taishi
    Sasano, Tetsuo
    Kakuta, Tsunekazu
    CIRCULATION JOURNAL, 2024, 88 (11) : 1788 - 1797
  • [25] Quantitative evaluation of capillaroscopic microvascular changes in patients with established coronary heart disease
    Esther Sanchez-Garcia, M.
    Ramirez-Lara, Irene
    Gomez-Delgado, Francisco
    Yubero-Serrano, Elena M.
    Leon-Acuna, Ana
    Marin, Carmen
    Alcala-Diaz, Juan F.
    Camargo, Antonio
    Lopez-Moreno, Javier
    Perez-Martinez, Pablo
    Jose Tinahones, Francisco
    Ordovas, Jose M.
    Caballero, Javier
    Blanco-Molina, Angeles
    Lopez-Miranda, Jose
    Delgado-Lista, Javier
    MEDICINA CLINICA, 2018, 150 (04): : 131 - 137
  • [26] Pathophysiology of coronary blood flow in congenital heart disease
    Aburawi, Elhadi H.
    Pesonen, Erkki
    INTERNATIONAL JOURNAL OF CARDIOLOGY, 2011, 151 (03) : 273 - 277
  • [27] Thermodilution-Derived Coronary Microvascular Resistance and Flow Reserve in Patients With Cardiac Syndrome X
    Luo, Chufan
    Long, Ming
    Hu, Xun
    Huang, Zhibin
    Hu, Chengheng
    Gao, Xiuren
    Du, Zhimin
    CIRCULATION-CARDIOVASCULAR INTERVENTIONS, 2014, 7 (01) : 43 - 48
  • [28] Novel mechanisms for cerebral blood flow regulation in patients with congenital heart disease
    Saiki, Hirofumi
    Sugimoto, Masaya
    Kuwata, Seiko
    Kurishima, Clara
    Iwamoto, Yoichi
    Ishido, Hirotaka
    Masutani, Satoshi
    Senzaki, Hideaki
    AMERICAN HEART JOURNAL, 2016, 172 : 152 - 159
  • [29] Effect of cardiac resynchronisation therapy on coronary blood flow in patients with non-ischaemic dilated cardiomyopathy
    Kazmierczak, Jaroslaw
    Peregud-Pogorzelska, Malgorzata
    Goracy, Jaroslaw
    Wojtarowicz, Andrzej
    Kiedrowicz, Radoslaw
    Kornacewicz-Jach, Zdzislawa
    KARDIOLOGIA POLSKA, 2014, 72 (06) : 511 - 518
  • [30] Remote Ischemic Preconditioning Stimulus Does Not Reduce Microvascular Resistance or Improve Myocardial Blood Flow in Patients Undergoing Elective Percutaneous Coronary Intervention
    Hoole, Stephen P.
    Heck, Patrick M.
    White, Paul A.
    Khan, Sadia N.
    O'Sullivan, Michael
    Clarke, Sarah C.
    Dutka, David P.
    ANGIOLOGY, 2009, 60 (04) : 403 - 411