Value of attenuation correction on ECG-gated SPECT myocardial perfusion imaging related to body mass index

被引:89
作者
Thompson, RC
Heller, GV
Johnson, LL
Case, JA
Cullom, SJ
Garcia, EV
Jones, PG
Moutray, KL
Bateman, TM
机构
[1] St Lukes Hosp, Mid Amer Heart Inst, Kansas City, MO 64111 USA
[2] Cardiovasc Consultants, Kansas City, MO 64111 USA
[3] Hartford Hosp, Henry Low Heart Ctr, Hartford, CT 06115 USA
[4] Columbia Presbyterian Med Ctr, New York, NY 10032 USA
[5] Emory Univ, Atlanta, GA 30322 USA
关键词
attenuation correction; single photon emission computed tomography; body mass index;
D O I
10.1016/j.nuclcard.2004.12.298
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background. Obesity is a growing problem in the United States, and attenuation artifacts are more prevalent in this patient group. This study evaluated the impact of attenuation correction in patients with a high body mass index (BMI). Methods and Results. Three readers interpreted gated attenuation-corrected and non-attenuation-corrected rest/stress technetium 99m sestamibi myocardial perfusion imaging results in 116 patients (BMI < 30, n = 60; BMI >= 30, n = 56) who had coronary angiography no more than 60 days after imaging. Readers were blinded to all clinical information and as to whether myocardial perfusion imaging was attenuation-corrected or non-attenuation-corrected. Sensitivity, specificity, and accuracy for detection of coronary artery disease of 70% or greater for attenuation-corrected versus non-attenuation-corrected single photon emission computed tomography (SPECT) were 86% versus 89%, 79% versus 50%, and 84% versus 79%, respectively. Sensitivity, specificity, and accuracy for attenuation-corrected versus non-attenuation-corrected SPECT for patients with BMI less than 30 were 90% versus 90%, 82% versus 64%, and 88% versus 85%, respectively. For BMI of 30 or greater, the results were 82% versus 87%, 76% versus 41%, and 80% versus 73%, respectively. There was a significant difference in specificity overall (P = .02) and for the category of BMI of 30 or greater (P = .03). Conclusions. This study demonstrates that electrocardiography-gated attenuation-corrected Tc-99m sestamibi SPECT myocardial perfusion imaging improves specificity compared with electrocardiography-gated non-attenuation-corrected SPECT myocardial perfusion imaging, especially in patients with BMI of 30 or greater.
引用
收藏
页码:195 / 202
页数:8
相关论文
共 50 条
[1]   Value of attenuation correction on ECG-gated SPECT myocardial perfusion imaging related to body mass index [J].
Randall C. Thompson ;
Gary V. Heller ;
Lynne L. Johnson ;
James A. Case ;
S. James Cullom ;
Ernest V. Garcia ;
Philip G. Jones ;
Kelly L. Moutray ;
Timothy M. Bateman .
Journal of Nuclear Cardiology, 2005, 12 :195-202
[2]   Impact of attenuation correction and gated acquisition in SPECT myocardial perfusion imaging: results of the multicentre SPAG (SPECT Attenuation Correction vs Gated) study [J].
Genovesi, Dario ;
Giorgetti, Assuero ;
Gimelli, Alessia ;
Kusch, Annette ;
Tagliavia, Irene D'Aragona ;
Casagranda, Mirta ;
Cannizzaro, Giorgio ;
Giubbini, Raffaele ;
Bertagna, Francesco ;
Fagioli, Giorgio ;
Rossi, Massimiliano ;
Romeo, Annadina ;
Bertolaccini, Pietro ;
Bonini, Rita ;
Marzullo, Paolo .
EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2011, 38 (10) :1890-1898
[3]   Impact of attenuation correction and gated acquisition in SPECT myocardial perfusion imaging: results of the multicentre SPAG (SPECT Attenuation Correction vs Gated) study [J].
Dario Genovesi ;
Assuero Giorgetti ;
Alessia Gimelli ;
Annette Kusch ;
Irene D’Aragona Tagliavia ;
Mirta Casagranda ;
Giorgio Cannizzaro ;
Raffaele Giubbini ;
Francesco Bertagna ;
Giorgio Fagioli ;
Massimiliano Rossi ;
Annadina Romeo ;
Pietro Bertolaccini ;
Rita Bonini ;
Paolo Marzullo .
European Journal of Nuclear Medicine and Molecular Imaging, 2011, 38 :1890-1898
[4]   Impact of image reconstruction on phase analysis of ECG-gated myocardial perfusion SPECT studies [J].
Li, Dianfu ;
Zhou, Yanli ;
Feng, Jianlin ;
Yuan, Donglan ;
Cao, Kejiang ;
Garcia, Ernest V. ;
Chen, Ji .
NUCLEAR MEDICINE COMMUNICATIONS, 2009, 30 (09) :700-705
[5]   Attenuation correction of myocardial perfusion SPET in patients of normal body mass index [J].
Shawgi, Mohamed ;
Tonge, Christine M. ;
Lawson, Richard S. ;
Muthu, Sivakumar ;
James, Jacqueline ;
Arumugam, Parthiban .
HELLENIC JOURNAL OF NUCLEAR MEDICINE, 2012, 15 (03) :215-219
[6]   Incremental Prognostic Value of Cardiac Function Assessed by ECG-Gated Myocardial Perfusion SPECT for the Prediction of Future Acute Coronary Syndrome [J].
Matsumoto, Naoya ;
Sato, Yuichi ;
Suzuki, Yasuyuki ;
Kasama, Shu ;
Nakano, Yoshimochi ;
Kato, Masahiko ;
Yoda, Shunichi ;
Miki, Takaaki ;
Iida, Jun ;
Kunimasa, Taeko ;
Tadehara, Futoshi ;
Nagao, Ken ;
Hirayama, Atsushi .
CIRCULATION JOURNAL, 2008, 72 (12) :2035-2039
[7]   Assessment of left ventricular volume and ejection fraction: comparison of QGS and MBGS analyses of ECG-gated myocardial perfusion SPECT imaging [J].
Khorsand, Aliasghar ;
Gyoengyoesi, Mariann ;
Graf, Senta ;
Zamini, Sholeh ;
Schuster, Ernst ;
Sochor, Heinz ;
Porenta, Gerold .
NUCLEAR MEDICINE COMMUNICATIONS, 2009, 30 (04) :300-307
[8]   Scatter and attenuation correction changes interpretation of gated myocardial perfusion imaging [J].
Allan Johansen ;
Peter Grupe ;
Annegrete Veje ;
Poul-Erik Nielsen Braad ;
Poul Flemming Høilund-Carlsen .
European Journal of Nuclear Medicine and Molecular Imaging, 2004, 31 :1152-1159
[9]   Half-Time SPECT Myocardial Perfusion Imaging with Attenuation Correction [J].
Ali, Iftikhar ;
Ruddy, Terrence D. ;
Almgrahi, Abdulaziz ;
Anstett, Frank G. ;
Wells, R. Glenn .
JOURNAL OF NUCLEAR MEDICINE, 2009, 50 (04) :554-562
[10]   Scatter and attenuation correction changes interpretation of gated myocardial perfusion imaging [J].
Johansen, A ;
Grupe, P ;
Veje, A ;
Braad, PEN ;
Hoilund-Carlsen, PF .
EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2004, 31 (08) :1152-1159