Observations on retrieved humeral polyethylene components from reverse total shoulder arthroplasty

被引:55
作者
Nam, Denis [1 ]
Kepler, Christopher K. [1 ]
Nho, Shane J. [1 ]
Craig, Edward V. [1 ]
Warren, Russell F. [1 ]
Wright, Timothy M. [2 ]
机构
[1] Cornell Univ, Hosp Special Surg, Dept Orthopaed Surg, Sports Med & Shoulder Serv,Weill Med Coll, New York, NY 10021 USA
[2] Cornell Univ, Hosp Special Surg, Dept Biomech, Weill Med Coll, New York, NY 10021 USA
关键词
Reverse total shoulder arthroplasty; polyethylene; damage modes; impingement; fatigue failure; instability; CUFF; PROSTHESIS; ARTHRITIS; HEMIARTHROPLASTY; OSTEOARTHRITIS; SEQUELAE; DESIGN; WEAR;
D O I
10.1016/j.jse.2010.05.014
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Hypothesis: Analyses of polyethylene components retrieved at revision of total knee, hip, and shoulder replacements have been used to study the effect of design, patient, and surgical factors on initial implant performance, but no studies have reported similar types of findings in retrieved humeral polyethylene components in reverse total shoulder arthroplasty. Our hypothesis is that while the conforming surface of the humeral polyethylene may predispose it to surface wear modalities, as seen in total hip arthroplasty, the presence of clinical instability may also increase the occurrence of focal contact stresses leading to subsurface fatigue failure Materials and methods: Fourteen humeral polyethylene components were retrieved from revision surgery at a single institution. Each polyethylene was analyzed for 9 modes of damage in each of 4 quadrants into which the bearing surface was divided For each implant, the most recent radiographs before removal were scored using an adapted radiolucency score, and glenosphere positioning was measured. Results: Despite the short mean length of implantation (0.46 +/- 0.5 years), scratching and abrasion were seen in 14 and 13 components, respectively, followed by third-body debris and pitting. The modes of damage observed were most severe in the inferior quadrant of the humeral polyethylene. Scapular notching, glenoid, and humeral radiolucencies were prevalent on preoperative radiographs, but their long-term significance has not yet been elucidated Increased glenosphere inclination was associated with decreased superior and total glenoid radiolucency, along with total polyethylene wear scores Discussion: Promising early, functional results with the use of reverse total shoulder arthroplasty has led to the increased expansion of its use, but high complication and revision rates continue to raise concerns regarding implant longevity The presence of a clinical, adduction deficit may predispose patients to inferior quadrant polyethylene wear. Conclusions: Impingement of the humeral polyethylene at the lateral edge of the scapula leads to inferior quadrant wear and associated polyethylene failure, and implant instability may predispose the components to fatigue wear mechanisms Analysis of retrieved humeral polyethylene components, along with patient, design, and surgical factors, provide important information on the causes of component failure. Level of evidence: Basic Science Study. (C) 2010 Journal of Shoulder and Elbow Surgery Board of Trustees
引用
收藏
页码:1003 / 1012
页数:10
相关论文
共 43 条
  • [1] [Anonymous], ADV RECONSTRUCTION S
  • [2] BASAMANIA C, 2007, ADV RECONSTRUCTION S, P567
  • [3] Shoulder arthroplasty for the treatment of the sequelae of fractures of the proximal humerus
    Boileau, P
    Trojani, C
    Walch, G
    Krishnan, SG
    Romeo, A
    Sinnerton, R
    [J]. JOURNAL OF SHOULDER AND ELBOW SURGERY, 2001, 10 (04) : 299 - 308
  • [4] Grammont reverse prosthesis: Design, rationale, and biomechanics
    Boileau, P
    Watkinson, DJ
    Hatzidakis, AM
    Balg, F
    [J]. JOURNAL OF SHOULDER AND ELBOW SURGERY, 2005, 14 (01) : 147S - 161S
  • [5] Neer Award 2005: The Grammont reverse shoulder prosthesis: Results in cuff tear arthritis, fracture sequelae, and revision arthroplasty
    Boileau, Pascal
    Watkinson, Duncan
    Hatzidakis, Armodios M.
    Hovorka, Istvan
    [J]. JOURNAL OF SHOULDER AND ELBOW SURGERY, 2006, 15 (05) : 527 - 540
  • [6] COLLIER JP, 1991, CLIN ORTHOP RELAT R, P232
  • [7] Shoulder prostheses treating cuff tear arthropathy: a comparative biomechanical study
    De Wilde, LF
    Audenaert, EA
    Berghs, BM
    [J]. JOURNAL OF ORTHOPAEDIC RESEARCH, 2004, 22 (06) : 1222 - 1230
  • [8] Rotator cuff tear arthropathy
    Ecklund, Kier J.
    Lee, Thay Q.
    Tibone, James
    Gupta, Ranjan
    [J]. JOURNAL OF THE AMERICAN ACADEMY OF ORTHOPAEDIC SURGEONS, 2007, 15 (06) : 340 - 349
  • [9] The influence of rotator cuff disease on the results of shoulder arthroplasty for primary osteoarthritis -: Results of a multicenter study
    Edwards, TB
    Boulahia, A
    Kempf, JF
    Boileau, P
    Némoz, C
    Walch, G
    [J]. JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2002, 84A (12) : 2240 - 2248