Measurement of intracellular pH in cultured cells by flow cytometry with BCECF-AM

被引:50
作者
Franck, P
Petitipain, N
Cherlet, M
Dardennes, M
Maachi, F
Schutz, B
Poisson, L
Nabet, P
机构
[1] FAC MED NANCY, LAB BIOCHIM MED 1, F-54505 VANDOEUVRE LES NANCY, FRANCE
[2] IBM CORP, F-54505 VANDOEUVRE LES NANCY, FRANCE
[3] CNRS, LAB SCI GENIE CHIM, F-54500 NANCY, FRANCE
关键词
intracellular pH; flow cytometry; BCECF; hybridoma cells; CARBOXY-SNARF-1;
D O I
10.1016/0168-1656(95)00189-1
中图分类号
Q81 [生物工程学(生物技术)]; Q93 [微生物学];
学科分类号
071005 ; 0836 ; 090102 ; 100705 ;
摘要
This study evaluates the suitability of flow cytometry with the fluorochrome BCECF for measuring the intracellular pH (pH(i)) of cultured cells, and monitors the changes in pH(i) in murine hybridoma in batch culture and chick embryo fibroblast in monolayer culture (5th passage). The technique produced highly reproducible, repeatable results. The theoretical sensitivity from the calibration curve was 0.0004 pH units. But analysis of the standard deviation of the histogram of the green/red fluorescence ratios indicated a mean sensitivity of 0.08 (0.07-0.09) pH units. Interference due to cell size, fluorochrome incorporation and esterases were minimized by establishing a calibration curve with the cells whose pH(i) was to be measured using the 525/610 nm fluorescence ratio after excitation at 488 nm. The pH(i) of exponentially growing, batch cultured hybridomas was 7.50 at the start of culture. pH(i) increased during the exponential growth phase and dropped towards cell death. The pH(i) of the chick fibroblasts in monolayer culture was 7.30.
引用
收藏
页码:187 / 195
页数:9
相关论文
共 22 条
  • [1] ALRUBEAI M, 1991, ESACT 11 M 2 6 SEPT
  • [2] INTRACELLULAR PH MEASUREMENT USING SINGLE EXCITATION-DUAL EMISSION FLUORESCENCE RATIOS
    BASSNETT, S
    REINISCH, L
    BEEBE, DC
    [J]. AMERICAN JOURNAL OF PHYSIOLOGY, 1990, 258 (01): : C171 - C178
  • [3] INTRACELLULAR PH MEASUREMENTS USING FLOW-CYTOMETRY WITH 1,4-DIACETOXY-2,3-DICYANOBENZENE
    COOK, JA
    FOX, MH
    [J]. CYTOMETRY, 1988, 9 (05): : 441 - 447
  • [4] FEATURES OF APOPTOTIC CELLS MEASURED BY FLOW-CYTOMETRY
    DARZYNKIEWICZ, Z
    BRUNO, S
    DELBINO, G
    GORCZYCA, W
    HOTZ, MA
    LASSOTA, P
    TRAGANOS, F
    [J]. CYTOMETRY, 1992, 13 (08): : 795 - 808
  • [5] IMMUNO AND FLOW CYTOMETRIC ANALYTICAL METHODS FOR BIOTECHNOLOGICAL RESEARCH AND PROCESS MONITORING
    DEGELAU, A
    FREITAG, R
    LINZ, F
    MIDDENDORF, C
    SCHEPER, T
    BLEY, T
    MULLER, S
    STOLL, P
    REARDON, KF
    [J]. JOURNAL OF BIOTECHNOLOGY, 1992, 25 (1-2) : 115 - 144
  • [6] INTRACELLULAR PH AND SURFACE PH IN SKELETAL AND CARDIAC-MUSCLE MEASURED WITH A DOUBLE-BARRELLED PH MICROELECTRODE
    DEHEMPTINNE, A
    [J]. PFLUGERS ARCHIV-EUROPEAN JOURNAL OF PHYSIOLOGY, 1980, 386 (02): : 121 - 126
  • [7] FLOW CYTOMETRIC MEASUREMENT OF INTRACELLULAR PH IN B-16 TUMORS - INTERCELL VARIANCE AND EFFECTS OF PRETREATMENT WITH GLUCOSE
    HEDLEY, DW
    JORGENSEN, HB
    [J]. EXPERIMENTAL CELL RESEARCH, 1989, 180 (01) : 106 - 116
  • [8] INONE I, 1989, J CELL PHYSL, V105, P461
  • [9] JUSTEMENT LB, 1990, NONINVASIVE TECHNIQU, P353
  • [10] MEASUREMENT OF CYTO-TOXICITY BY TARGET-CELL RELEASE AND RETENTION OF THE FLUORESCENT DYE BIS-CARBOXYETHYL-CARBOXYFLUORESCEIN (BCECF)
    KOLBER, MA
    QUINONES, RR
    GRESS, RE
    HENKART, PA
    [J]. JOURNAL OF IMMUNOLOGICAL METHODS, 1988, 108 (1-2) : 255 - 264