Development of a methodology for the determination of polychlorinated biphenyls in soil samples

被引:3
作者
Wojtowicz, Katarzyna [1 ]
Jakubowicz, Piotr [1 ]
机构
[1] Inst Nasty & Gazu, Panstwowy Inst Badawczy, Zakladzie Technol Eksploatacji Plynow Zlozowych, Ul Lubicz 25 A, PL-31503 Krakow, Poland
来源
NAFTA-GAZ | 2019年 / 07期
关键词
polychlorinated biphenyls; gas chromatography; electron capture detector (ECD); extraction; solid phase extraction SPE; PAHS; PCB;
D O I
10.18668/NG.2019.07.06
中图分类号
TE [石油、天然气工业];
学科分类号
0820 ;
摘要
The article presents issues related to the development of the chromatographic methodology for determining polychlorinated biphenyls in soil samples. For this purpose, a gas chromatograph equipped with an electron capture detector (GC-ECD) from Perkin Elmer was used. As part of the research, optimal chromatograph parameters were determined, such as injector temperature, ECD detector temperature, oven temperature course during chromatographic analysis, time of analysis and a chromatographic column allowing selective separation of analytes. Then, the chromatographic system was calibrated and the analytical method for polychlorinated biphenyls determination was validated, based on the Supelco and Sigma-Aldrich reference solutions with numbers 47330-U and 36989, respectively. Calibration curves for each of the congeners tested were PCB (PCB-10, PCB-28, PCB-53, PCB-101, PCB-138, PCB-153, PCB-180, PCB-209) in two concentration ranges. The validation of the analytical method included the determination of linearity, standard deviation, relative standard deviation, detection limit (LOD) and limit of quantification (LOQ) of the above PCB congeners. To this end, the development of the methodology for preparing soil samples for chromatographic analysis has been tested for the selection of the extraction method (extraction with solvent assisted by shaking, extraction with ultrasonic assisted solvent, solvent extraction in a Soxhlet apparatus), solvent/solvent system selection (n- hexane, a mixture of n-hexane and dichloromethane in a 1:1 ratio) and selection of sorption material in the SPE solid phase extraction stage (columns for special tasks, Florisil packed columns). Model samples used soil contaminated with the Supelco standard solution number 47330-U. For all the combinations of the above-mentioned conditions of preparing the sample for chromatographic analysis, the recovery rate of individual analytes was calculated. On the basis of chromatographic analyses and recovery levels, the most optimal methodology for preparing soil samples for chromatographic analysis was selected for the determination of polychlorinated biphenyls. The developed methodology for the determination of polychlorinated biphenyls in soil samples was tested on real samples of soils contaminated with aged transformer oil taken from the areas of south-eastern Poland. The analytical procedure for the determination of PCBs in soil samples included: initial sample preparation (drying, milling, homogenization), isolation of analytes from the sample matrix (solvent extraction assisted by shaking with a 1:1 mixture of solvents n-hexane: dichloromethane), sample purification from disturbing substances (a set of two columns for SPE extraction: Silica gel No. 7086-03 and PCB-A No. 7511-04 from Bakerbond), chromatographic analysis. The application of the above-mentioned analytical techniques allowed to obtain information on the content of polychlorinated biphenyls investigated in soils samples.
引用
收藏
页码:420 / 429
页数:10
相关论文
共 50 条
  • [21] RAPID CHROMATOGRAPHY FOR THE DETERMINATION OF POLYCHLORINATED BIPHENYLS BY GC-MS IN ENVIRONMENTAL MONITORING
    Nikonova, Alyona A.
    Gorshkov, Alexander G.
    ANALYTICAL LETTERS, 2011, 44 (07) : 1290 - 1300
  • [22] Determination of 26 polychlorinated biphenyls congeners in soil samples using microwave-assisted extraction with open vessel and gas chromatography
    Halfadji, Ahmed
    Touabet, Abdelkrim
    GREEN CHEMISTRY LETTERS AND REVIEWS, 2018, 11 (03) : 209 - 216
  • [23] Determination of polychlorinated biphenyls by fast chromatography mass-spectrometry in environmental and biological samples
    Nikonova, A. A.
    Gorshkov, A. G.
    JOURNAL OF ANALYTICAL CHEMISTRY, 2012, 67 (01) : 72 - 80
  • [24] Determination of polychlorinated biphenyls by fast chromatography mass-spectrometry in environmental and biological samples
    A. A. Nikonova
    A. G. Gorshkov
    Journal of Analytical Chemistry, 2012, 67 : 72 - 80
  • [25] Determination of polychlorinated biphenyls in honeybee, pollen, and honey samples from urban and semi-urban areas in Turkey
    Sari, Mehmet Ferhat
    Ayyildiz, Emine Gurkan
    Esen, Fatma
    ENVIRONMENTAL SCIENCE AND POLLUTION RESEARCH, 2020, 27 (04) : 4414 - 4422
  • [26] Validation of an analytical procedure for polychlorinated biphenyls, coplanar polychlorinated biphenyls and polycyclic aromatic hydrocarbons in environmental samples
    Jaouen-Madoulet, A
    Abarnou, A
    Le Guellec, AM
    Loizeau, V
    Leboulenger, F
    JOURNAL OF CHROMATOGRAPHY A, 2000, 886 (1-2) : 153 - 173
  • [27] Determination of polychlorinated biphenyls, organochlorine pesticides, chlorobenzenes in sludge and sediment samples by GC x GC-μECD
    Muscalu, Alina M.
    Reiner, Eric J.
    Liss, Steven N.
    Chen, Tony
    INTERNATIONAL JOURNAL OF ENVIRONMENTAL ANALYTICAL CHEMISTRY, 2010, 90 (01) : 1 - 13
  • [28] Polychlorinated Biphenyls Residues in the Soil in Linfen, China
    S. Fu
    H. Cheng
    Y. Liu
    L. Zhang
    Z. Yang
    K. Li
    X. Xia
    X. Xu
    Bulletin of Environmental Contamination and Toxicology, 2008, 81 : 594 - 598
  • [29] Microextraction techniques for sampling and determination of polychlorinated biphenyls: A comprehensive review
    Jalili, Vahid
    Kakavandi, Masoud Ghanbari
    Ghiasvand, Alireza
    Barkhordari, Abdullah
    MICROCHEMICAL JOURNAL, 2022, 179
  • [30] Calibration of the electron-capture detector for the determination of polychlorinated biphenyls
    Booij, K
    Hillebrand, MTJ
    van Weerlee, EM
    ANALYST, 1998, 123 (03) : 415 - 420