Development of a methodology for the determination of polychlorinated biphenyls in soil samples

被引:3
作者
Wojtowicz, Katarzyna [1 ]
Jakubowicz, Piotr [1 ]
机构
[1] Inst Nasty & Gazu, Panstwowy Inst Badawczy, Zakladzie Technol Eksploatacji Plynow Zlozowych, Ul Lubicz 25 A, PL-31503 Krakow, Poland
来源
NAFTA-GAZ | 2019年 / 07期
关键词
polychlorinated biphenyls; gas chromatography; electron capture detector (ECD); extraction; solid phase extraction SPE; PAHS; PCB;
D O I
10.18668/NG.2019.07.06
中图分类号
TE [石油、天然气工业];
学科分类号
0820 ;
摘要
The article presents issues related to the development of the chromatographic methodology for determining polychlorinated biphenyls in soil samples. For this purpose, a gas chromatograph equipped with an electron capture detector (GC-ECD) from Perkin Elmer was used. As part of the research, optimal chromatograph parameters were determined, such as injector temperature, ECD detector temperature, oven temperature course during chromatographic analysis, time of analysis and a chromatographic column allowing selective separation of analytes. Then, the chromatographic system was calibrated and the analytical method for polychlorinated biphenyls determination was validated, based on the Supelco and Sigma-Aldrich reference solutions with numbers 47330-U and 36989, respectively. Calibration curves for each of the congeners tested were PCB (PCB-10, PCB-28, PCB-53, PCB-101, PCB-138, PCB-153, PCB-180, PCB-209) in two concentration ranges. The validation of the analytical method included the determination of linearity, standard deviation, relative standard deviation, detection limit (LOD) and limit of quantification (LOQ) of the above PCB congeners. To this end, the development of the methodology for preparing soil samples for chromatographic analysis has been tested for the selection of the extraction method (extraction with solvent assisted by shaking, extraction with ultrasonic assisted solvent, solvent extraction in a Soxhlet apparatus), solvent/solvent system selection (n- hexane, a mixture of n-hexane and dichloromethane in a 1:1 ratio) and selection of sorption material in the SPE solid phase extraction stage (columns for special tasks, Florisil packed columns). Model samples used soil contaminated with the Supelco standard solution number 47330-U. For all the combinations of the above-mentioned conditions of preparing the sample for chromatographic analysis, the recovery rate of individual analytes was calculated. On the basis of chromatographic analyses and recovery levels, the most optimal methodology for preparing soil samples for chromatographic analysis was selected for the determination of polychlorinated biphenyls. The developed methodology for the determination of polychlorinated biphenyls in soil samples was tested on real samples of soils contaminated with aged transformer oil taken from the areas of south-eastern Poland. The analytical procedure for the determination of PCBs in soil samples included: initial sample preparation (drying, milling, homogenization), isolation of analytes from the sample matrix (solvent extraction assisted by shaking with a 1:1 mixture of solvents n-hexane: dichloromethane), sample purification from disturbing substances (a set of two columns for SPE extraction: Silica gel No. 7086-03 and PCB-A No. 7511-04 from Bakerbond), chromatographic analysis. The application of the above-mentioned analytical techniques allowed to obtain information on the content of polychlorinated biphenyls investigated in soils samples.
引用
收藏
页码:420 / 429
页数:10
相关论文
共 50 条
  • [1] Direct competitive ELISA for the determination of polychlorinated biphenyls in soil samples
    Deng, AP
    Kolár, V
    Ulrich, R
    Fránek, M
    ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2002, 373 (08) : 685 - 690
  • [2] Validation of the GCMS method for the determination of polychlorinated biphenyls congeners in soil and sediment samples
    Nenin, Tanja
    Mitrovic, Tatjana
    Petkovic, Andelka
    Colic, Jasna
    MICROCHEMICAL JOURNAL, 2024, 207
  • [3] Evaluation of the method of determination of selected polychlorinated biphenyls in soil samples
    Lulek, J
    Szafran, B
    Górzynska, A
    CHEMIA ANALITYCZNA, 2000, 45 (01): : 35 - 43
  • [4] Development of a Method for the Determination of Polychlorinated Biphenyls in Microplastics Present in Marine Samples
    Nieves, Carro
    Julio, Cobas
    Nahid, Brikat
    Isabel, Garcia
    Maria, Ignacio
    Ana, Mouteira
    JOURNAL OF ANALYTICAL CHEMISTRY, 2021, 76 (08) : 960 - 974
  • [5] The effect of adding a standard on the result of determination of polychlorinated biphenyls in bottom sediment samples
    Mechlinska, Agata
    Wolska, Lidia
    Namiesnik, Jacek
    TALANTA, 2010, 82 (02) : 627 - 630
  • [6] Validation a methodology analytical to determine polychlorinated biphenyls in blood plasma samples
    Avila, B. S.
    Ramirez, C.
    BIOMEDICA, 2017, 37 (04):
  • [7] Methods of determination of residues of pesticides and polychlorinated biphenyls in food samples - A review
    Beyer, Angelika
    Biziuk, Marek
    ECOLOGICAL CHEMISTRY AND ENGINEERING-CHEMIA I INZYNIERIA EKOLOGICZNA, 2007, 14 (S3): : 291 - 313
  • [8] Development of a methodology for the determination of PAH in soil samples using HPLC
    Wojtowicz, Katarzyna
    NAFTA-GAZ, 2022, (02): : 141 - 153
  • [9] Development of the QuEChERS Extraction Method for the Determination of Polychlorinated Biphenyls (Aroclor 1254) in Soil Samples by Using GC-MS
    Alsefri, Samia
    Balbaied, Thanih
    Alatawi, Hanan
    Albalawi, Ibtihaj
    Hogan, Anna
    Moore, Eric
    SEPARATIONS, 2023, 10 (04)
  • [10] Optimisation of Pressurized Liquid Extraction for the Determination of Seven Selected Polychlorinated Biphenyls in Feed Samples
    C. von Holst
    A. Müller
    F. Serano
    S. Sporring
    E. Björklund
    Chromatographia, 2005, 61 : 391 - 396