Comparison of methods and confirmation tests for the recovery Escherichia coli in water

被引:14
作者
Bonadonna, L. [1 ]
Cataldo, C. [1 ]
Semproni, M. [1 ]
机构
[1] Ist Super Sanita, Dept Environm & Primary Prevent, I-00161 Rome, Italy
关键词
E; coli; ISO method; microbiological methods; water;
D O I
10.1016/j.desal.2006.03.601
中图分类号
TQ [化学工业];
学科分类号
0817 ;
摘要
Data are presented on a study carried out on water analyzed with three different methods. Thus, a comparison was performed in parallel with the ISO 9308-1 reference method, stated by the European Drinking Water Directive, and two enzyme-based methods, the Colilert 18/Quanti-Tray (TM) and the Chromogenic E. coli Agar. Phenotypical characteristics of presumptive E. coli and confirmation tests of the isolates were evaluated. The selectivity of the ISO method, combined with selective confirmation steps, has resulted in lower E. coli counts in comparison with the two alternative methods. In fact, the method failed to detect a significant proportion of the target microorganisms; furthermore, it allowed the growth of other bacterial species, mainly Klebsiella oxytoca. The two alternative methods were more sensitive than the ISO procedure and were able to sustain the growth of different fractions of bacterial populations. Particularly, the Colilert was able to detect qualitatively and quantitatively a higher proportion of E. coli. Furthermore, the hydrolysis of 4-methyl-umbelliferyl-beta-D-glucuronide as a marker for E. coli seems to be a more appropriate procedure for the identification of the target microorganisms with respect to the more traditional test for indole production.
引用
收藏
页码:18 / 23
页数:6
相关论文
共 24 条
  • [1] [Anonymous], OFFICIAL J EUROPEA L
  • [2] BARONE E, IN PRESS BIOL AMBIEN
  • [3] BOANDONNA L, 2005, IGIENE SANTIA PUBBLI, V61, P48
  • [4] BUTTIAUX R., 1948, ANN INST PASTEUR LILLE, V1, P103
  • [5] An alternative approach for enumeration of Escherichia coli in foods
    Cakir, I
    Dogan, HB
    Halkman, AK
    Worobo, RW
    [J]. INTERNATIONAL JOURNAL OF FOOD MICROBIOLOGY, 2001, 68 (03) : 217 - 223
  • [6] CHAPMAN GH, 1951, AM J PUBLIC HEALTH, V41, P1381
  • [7] A PRELIMINARY-STUDY OF THE USE OF COLILERT FOR WATER-QUALITY MONITORING
    COWBURN, JK
    GOODALL, T
    FRICKER, EJ
    WALTER, KS
    FRICKER, CR
    [J]. LETTERS IN APPLIED MICROBIOLOGY, 1994, 19 (01) : 50 - 52
  • [8] *DEP ENV, 2000, DEINK WAT INSP MICR
  • [9] Use of two formulations of Colilert and QuantiTray(TM) for assessment of the bacteriological quality of water
    Fricker, EJ
    Illingworth, KS
    Fricker, CR
    [J]. WATER RESEARCH, 1997, 31 (10) : 2495 - 2499
  • [10] ENTEROBACTERIACEAE OF THE COLIFORM GROUP IN DRINKING-WATER - IDENTIFICATION AND WORLDWIDE DISTRIBUTION
    GAVINI, F
    LECLERC, H
    MOSSEL, DAA
    [J]. SYSTEMATIC AND APPLIED MICROBIOLOGY, 1985, 6 (03) : 312 - 318