The Effect of Peri-Bracket Excess Adhesive on Shear Bond Strength and Enamel-Adhesive Interface Morphology With Confocal Laser Scanning Microscopy: An In Vitro Comparative Study

被引:0
作者
Almashali, Banan [1 ,2 ]
Alqahtani, Nasser [1 ]
Almahdy, Ahmed [1 ]
机构
[1] King Saud Univ, Coll Dent, Dept Pediat Dent & Orthodont, POB 231903, Riyadh 11321, Saudi Arabia
[2] Princess Nourah Bint Abdulrahman Univ, Coll Dent, Dept Prevent Dent Sci, Riyadh, Saudi Arabia
关键词
Shear bond strength; Orthodontic bonding; Confocal laser scanning microscopy; Excess adhesive; FLASH; TIME;
D O I
10.1177/2320206820987397
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Aim: To evaluate the effect of leaving excess adhesive around orthodontic brackets on the shear bond strength and on the enamel-adhesive interface characteristics. Materials and Methods: One hundred forty four human premolars were randomly divided into two groups according to the test performed. For the shear bond strength, 120 teeth were bonded with stainless steel orthodontic brackets using Transbond XT light cure adhesive composites. After positioning the bracket and before light curing, excess adhesive was removed according to the test group: group 1, all excess adhesive was removed (0 mm excess); group 2, 1 mm excess adhesive was left; group 3, 2 mm excess adhesive was left; shear bond strength was measured immediately and after three months of natural aging using a universal testing machine; and adhesive remnant index scores were also evaluated. For the enamel-adhesive interface characteristics, 24 teeth were bonded with stainless steel orthodontic brackets using Transbond XT light cure adhesive composites mixed with Rhodamine B fluorescent dye, excess adhesive was removed in the same manner according to the test groups, and teeth were evaluated using confocal laser scanning microscopy. Results: Time did not significantly affect the bond strength results (P = .888) but the amount of excess adhesive significantly affected the results (P < .05). Interaction terms were not significant (P = .337). In both immediate and aged conditions, group 1 (0 mm excess) presented the highest bond strength results (MPa; P < .05). No significant difference was found in adhesive remnant index scores or enamel-adhesive interface characteristics. Conclusion: Excess adhesive around orthodontic bracket does not increase shear bond strength.
引用
收藏
页码:229 / 236
页数:8
相关论文
共 25 条
  • [1] Marginal Integrity of Peri-Bracket Excess Adhesive. A Confocal Laser Scanning Microscopic Study
    Almashali, Banan
    Almandy, Ahmed
    Alqahtani, Nasser
    Alghamdi, Hanan
    BIOSCIENCE BIOTECHNOLOGY RESEARCH COMMUNICATIONS, 2021, 14 (01): : 118 - 123
  • [2] Shear bond strength of adhesive precoated brackets: A comparative in vitro study
    Miller, Mary
    Mon, Htwe H.
    Xu, Xiaoming
    Chapple, Andrew
    Dupree, Peter
    Ballard, Richard W.
    Armbruster, Paul
    INTERNATIONAL ORTHODONTICS, 2023, 21 (02)
  • [3] Shear Bond Strength and Excess Adhesive Surface Topography of Different Bonding Systems after Thermocycling: A Comparative In-vitro Study
    Dheyaa, Abd Sarah
    Al-Khatieeb, Mustafa M.
    INTERNATIONAL JOURNAL OF MEDICAL RESEARCH & HEALTH SCIENCES, 2018, 7 (03): : 46 - 54
  • [4] Comparative Evaluation on the Effect of Different Remineralizing Agents on Enamel-Bracket Shear Bond Strength: An In Vitro Study
    Joshi, Suyash S.
    Ninawe, Nupur S.
    Banda, Naveen Reddy
    Gala, Urvi
    Doiphode, Avani
    Honaje, Nilam
    CUREUS JOURNAL OF MEDICAL SCIENCE, 2023, 15 (09)
  • [5] Adhesive Precoated Bracket: Is It Worth Using? Long-term Shear Bond Strength: An In Vitro Study
    Vorachart, Weerada
    Sombuntham, Nonglak
    Parakonthun, Kulthida
    EUROPEAN JOURNAL OF DENTISTRY, 2022, 16 (04) : 841 - 847
  • [6] The effect of beer and milk tea on the shear bond strength of adhesive precoated brackets: An in vitro comparative study
    Vorachart, Weerada
    Sombuntham, Nonglak
    Parakonthun, Kulthida
    HELIYON, 2022, 8 (08)
  • [7] The influence of enamel sandblasting on the shear bond strength and fractography of the bracket-adhesive-enamel complex tested in vitro by the DIN 13990:2017-04 standard
    Nikolaos Daratsianos
    Beke Schütz
    Susanne Reimann
    Anna Weber
    Spyridon N. Papageorgiou
    Andreas Jäger
    Christoph Bourauel
    Clinical Oral Investigations, 2019, 23 : 2975 - 2985
  • [8] The influence of enamel sandblasting on the shear bond strength and fractography of the bracket-adhesive-enamel complex tested in vitro by the DIN 13990:2017-04 standard
    Daratsianos, Nikolaos
    Schuetz, Beke
    Reimann, Susanne
    Weber, Anna
    Papageorgiou, Spyridon N.
    Jaeger, Andreas
    Bourauel, Christoph
    CLINICAL ORAL INVESTIGATIONS, 2019, 23 (07) : 2975 - 2985
  • [9] Evaluation of shear bond strength and adhesive remnant index of metal APC™ Flash-Free adhesive system: A comparative in vitro study with APC™ II and uncoated metal brackets
    Akl, Roula
    Ghoubril, Joseph
    Le Gall, Michel
    Shatila, Rania
    Philip-Alliez, Camille
    INTERNATIONAL ORTHODONTICS, 2022, 20 (04)
  • [10] Effect of the Incorporation of Chitosan and TiO2 Nanoparticles on the Shear Bond Strength of an Orthodontic Adhesive: An In Vitro Study
    Farzanegan, Fahimeh
    Shafaee, Hooman
    Darroudi, Majid
    Rangrazi, Abdolrasoul
    JOURNAL OF ADVANCED ORAL RESEARCH, 2021, 12 (02) : 261 - 266