Optimal linear combination of ARFI, transient elastography and APRI for the assessment of fibrosis in chronic hepatitis B

被引:32
作者
Liu, Yingxia [1 ]
Dong, Chang Feng [1 ]
Yang, Guilin [1 ]
Liu, Jing [1 ]
Yao, Simin [1 ]
Li, Han Ying [1 ]
Yuan, Jing [1 ]
Li, Shaxi [1 ]
Le, Xiaohua [1 ]
Lin, Yimin [1 ]
Zeng, Wen [1 ]
Lin, Haoming [2 ]
Zhang, Xinyu [2 ]
Chen, Xin [2 ]
机构
[1] Shenzhen Third Peoples Hosp, Shenzhen Inst Hepatol, Shenzhen, Peoples R China
[2] Shenzhen Univ, Sch Med, Natl Reg Key Technol Engn Lab Med Ultrasound, Shenzhen 518060, Peoples R China
基金
中国国家自然科学基金;
关键词
acoustic radiation force impulse; aspartate aminotransferase-to-platelet ratio index; chronic hepatitis B; liver fibrosis; transient elastography; RADIATION FORCE IMPULSE; PLATELET RATIO INDEX; LIVER FIBROSIS; NONINVASIVE ASSESSMENT; DIAGNOSTIC-ACCURACY; STIFFNESS; DISEASE; ALGORITHMS; MARKERS; BIOPSY;
D O I
10.1111/liv.12564
中图分类号
R57 [消化系及腹部疾病];
学科分类号
摘要
Background & AimsAccurate assessment of liver fibrosis in patients with chronic hepatitis B (CHB) is necessary not only to predict the long-term clinical course but also to determine an appropriate antiviral therapy scheme. Several noninvasive approaches - serum markers and elastography - have been proposed as alternatives for the histopathological analysis of liver biopsies. The aim of this study was to evaluate two ultrasound elastography methods (ARFI and TE) and one biochemical test (APRI), as well as their optimal linear combination, in the assessment of liver fibrosis in CHB. MethodsNinety five patients with CHB and 16 volunteers underwent ARFI, TE and APRI; and liver fibrosis was staged in the patients by a liver biopsy. An optimal linear combination of the three methods was developed, and its diagnostic performance was evaluated by a 10-fold cross-validation. ResultsThe accuracy of the linear combination was 83.86% and 91.88% for significant fibrosis (F2) and cirrhosis (F4), respectively, higher than those obtained for ARFI (83.50%, 88.76%), TE (75.27%, 87.61%) and APRI (73.29% and 81.67%). The combination also increased the sensitivity and the negative predictive values for the diagnosis of significant fibrosis and cirrhosis. ConclusionsThe optimal linear combination algorithm is effective for noninvasive staging of liver fibrosis in CHB. However, linear combination has its own limitations; nonlinear methods may eventually reveal even clearer diagnostic results.
引用
收藏
页码:816 / 825
页数:10
相关论文
共 50 条
[31]   Performance of a New Elastographic Method (ARFI technology) Compared to Unidimensional Transient Elastography in the Noninvasive Assessment of Chronic Hepatitis C. Preliminary Results [J].
Lupsor, Monica ;
Badea, Radu ;
Stefanescu, Horia ;
Sparchez, Zeno ;
Branda, Horatiu ;
Serban, Alexandru ;
Maniu, Anca .
JOURNAL OF GASTROINTESTINAL AND LIVER DISEASES, 2009, 18 (03) :303-310
[32]   Transient elastography in chronic hepatitis B: An Asian perspective [J].
Kim, Seung Up ;
Han, Kwang-Hyub ;
Ahn, Sang Hoon .
WORLD JOURNAL OF GASTROENTEROLOGY, 2010, 16 (41) :5173-5180
[33]   COMPARISON OF ACOUSTIC RADIATION FORCE IMPULSE IMAGING AND TRANSIENT ELASTOGRAPHY FOR NON-INVASIVE ASSESSMENT OF LIVER FIBROSIS IN PATIENTS WITH CHRONIC HEPATITIS B [J].
Zhang, Dakun ;
Chen, Min ;
Wang, Ruifang ;
Liu, Yang ;
Zhang, Dedong ;
Liu, Liping ;
Zhou, Guangde .
ULTRASOUND IN MEDICINE AND BIOLOGY, 2015, 41 (01) :7-14
[34]   Correlation of MR Elastography with Morphometric Quantification of Liver Fibrosis (Fibro-C-Index) in Chronic Hepatitis B [J].
Venkatesh, Sudhakar K. ;
Xu, Shuoyu ;
Tai, Dean ;
Yu, Hanry ;
Wee, Aileen .
MAGNETIC RESONANCE IN MEDICINE, 2014, 72 (04) :1123-1129
[35]   ASSESSMENT OF LIVER FIBROSIS USING REAL-TIME SHEAR-WAVE ELASTOGRAPHY FOR PATIENTS WITH HEPATITIS B E ANTIGEN-NEGATIVE CHRONIC HEPATITIS B AND ALANINE TRANSAMINASE <2 TIMES THE UPPER LIMIT OF NORMAL [J].
Liu, Jing-Hua ;
Zou, Yu ;
Chang, Wei ;
Wu, Jun ;
Zou, Yu ;
Xie, Yu-Chen ;
Lu, Yong-Ping ;
Wei, Jia .
REVISTA DE INVESTIGACION CLINICA-CLINICAL AND TRANSLATIONAL INVESTIGATION, 2017, 69 (05) :254-261
[36]   A New Visual Transient Elastography Technique for Grading Liver Fibrosis in Patients With Chronic Hepatitis B [J].
Ren, Xinping ;
Zhang, Lu ;
Xia, Shujun ;
Chen, Zhijie ;
Zhou, Wei ;
Ji, Ri ;
Zhou, Jianqiao ;
Lin, Yanyan ;
Zhan, Weiwei .
ULTRASOUND QUARTERLY, 2021, 37 (02) :105-110
[37]   Assessment of liver fibrosis by transient elastography and multi-parameters model in young children with chronic hepatitis B virus infection [J].
Haiyan Luo ;
Songxu Peng ;
Wenxian Ouyang ;
Yanfang Tan ;
Tao Jiang ;
Lian Tang ;
Shuangjie Li ;
Jun Qiu ;
Changci Zhou .
BMC Infectious Diseases, 22
[38]   Two-dimensional shear wave elastography for significant liver fibrosis in patients with chronic hepatitis B: A systematic review and meta-analysis [J].
Wei, Hong ;
Jiang, Han-Yu ;
Li, Mou ;
Zhang, Tong ;
Song, Bin .
EUROPEAN JOURNAL OF RADIOLOGY, 2020, 124
[39]   Prospective comparison of transient elastography, point shear wave elastography, APRI and FIB-4 for staging liver fibrosis in chronic viral hepatitis [J].
Udompap, Prowpanga ;
Sukonrut, Kamonthip ;
Suvannarerg, Voraparee ;
Pongpaibul, Ananya ;
Charatcharoenwitthaya, Phunchai .
JOURNAL OF VIRAL HEPATITIS, 2020, 27 (04) :437-448
[40]   Is ARFI elastography reliable for predicting fibrosis severity in chronic HCV hepatitis? [J].
Ioan Sporea ;
Roxana Sirli ;
Simona Bota ;
Carmen Fierbinteanu-Braticevici ;
Alina Popescu ;
Radu Badea ;
Monica Lupsor ;
Ana Petrisor ;
Mirela Dnil .
World Journal of Radiology, 2011, (07) :188-193