Comparison of a collagen plug arterial closure device with manual compression after endovascular interventions for peripheral artery disease

被引:11
|
作者
Fokkema, Talje M. [1 ]
Minnee, Robert C. [1 ]
Kock, Gert-Aldert H. [2 ]
Blomjous, Joost G. A. M. [2 ]
Vahl, Anco C. [1 ]
Leijdekkers, Vanessa J. [1 ]
机构
[1] Onze Lieve Vrouw Hosp, Dept Vasc Surg, NL-1091 AC Amsterdam, Netherlands
[2] Onze Lieve Vrouw Hosp, Dept Intervent Radiol, NL-1091 AC Amsterdam, Netherlands
关键词
PERCUTANEOUS CORONARY INTERVENTIONS; ACCESS SITE COMPLICATIONS; CRITICAL LIMB ISCHEMIA; VASCULAR COMPLICATIONS; CARDIAC-CATHETERIZATION; HEMOSTASIS; METAANALYSIS; ARTERIOTOMY; PUNCTURE; TRIAL;
D O I
10.1016/j.jvs.2016.02.025
中图分类号
R61 [外科手术学];
学科分类号
摘要
Objective: Arterial closure devices (ACDs) seem to be safe and effective to obtain hemostasis for cardiac interventions and diagnostic vascular procedures. However, only limited evidence is presented on therapeutic interventions in patients with peripheral atherosclerotic disease. We compared ischemic and hemorrhagic complications of an ACD vs manual compression (MC) after puncture of the femoral artery for endovascular lower extremity procedures. Methods: The records of all subsequent endovascular interventions for peripheral artery disease performed in a large teaching hospital, from January 2012 to April 2014, were retrospectively reviewed. The primary outcome was an ischemic complication requiring reintervention. Secondary outcomes were hematoma (needing conservative or invasive intervention) and infection (needing intervention or antibiotics). Multivariate analysis was performed to identify predictors for any complication. Results: The Angio-Seal (St. Jude Medical, Minnetonka, Minn) closure device was used in 244 of 463 endovascular interventions (54%). Five patients (2%) who received an ACD needed emergency surgery for ischemic complications vs none in the MC group (P=.06). Hematomas occurred in 22 patients (9%) after ACD vs in six (3%) after MC(adjusted odds ratio [OR], 3.4; 95% confidence interval [CI], 1.4-8.9; P=.015). There were no infections in either group. ACD (OR, 3.8; 95% CI, 1.5-9.7) and current smoking (OR, 2.6; 95% CI, 1.01-6.7) were independent predictors for any complication. Conclusions: This study demonstrates that ACD use in patients with peripheral artery disease can lead to serious adverse events resulting in increased morbidity. Therefore, the potential benefits of an ACD over MC should be carefully weighed.
引用
收藏
页码:104 / +
页数:6
相关论文
共 50 条
  • [1] Comparison of costs and safety of a suture-mediated closure device with conventional manual compression after coronary artery interventions
    Rickli, H
    Unterweger, M
    Sütsch, G
    Brunner-La Rocca, HP
    Sagmeister, M
    Ammann, P
    Amann, FW
    CATHETERIZATION AND CARDIOVASCULAR INTERVENTIONS, 2002, 57 (03) : 297 - 302
  • [2] Comparison of manual compression with a new bioabsorbable vascular closure device in percutaneous peripheral procedures
    Khalil, Emced
    ANNALS OF CLINICAL AND ANALYTICAL MEDICINE, 2022, 13 (01): : 109 - 113
  • [3] Closure Device or Manual Compression in Patients Undergoing Percutaneous Coronary Intervention: A Randomized Comparison
    Hermanides, Renicus S.
    Ottervanger, Jan Paul
    Dambrink, Jan-Henk E.
    de Boer, Menko Jan
    Hoorntje, Jan C. A.
    Gosselink, A. T. Marcel
    Suryapranata, Harry
    van't Hof, Arnoud W. J.
    JOURNAL OF INVASIVE CARDIOLOGY, 2010, 22 (12) : 562 - 566
  • [4] Costs and Budget Impact of Collagen-Based Vascular Closure Device Versus Manual Compression Following Peripheral Endovascular Procedures
    Goueffic, Yann
    McWilliams, Richard
    Burton, Hannah
    Verin, Nathalie
    ANNALS OF VASCULAR SURGERY, 2023, 93 : 64 - 70
  • [5] Management of Patients After Endovascular Interventions for Peripheral Artery Disease
    Sobieszczyk, Piotr
    Eisenhauer, Andrew
    CIRCULATION, 2013, 128 (07) : 749 - 757
  • [6] Comparison of Collagen-Based Vascular Closure Devices in Patients With vs. Without Severe Peripheral Artery Disease
    Kara, Kaffer
    Kahlert, Philip
    Mahabadi, Amir A.
    Plicht, Bjoern
    Lind, Alexander Y.
    Longwitz, Detlev
    Bollow, Matthias
    Erbel, Raimund
    JOURNAL OF ENDOVASCULAR THERAPY, 2014, 21 (01) : 79 - 84
  • [7] Comparison of Bleeding Complications Using Arterial Closure Device Versus Manual Compression by Propensity Matching in Patients Undergoing Percutaneous Coronary Intervention
    Allen, Drew S.
    Marso, Steven P.
    Lindsey, Jason B.
    Kennedy, Kevin F.
    Safley, David M.
    AMERICAN JOURNAL OF CARDIOLOGY, 2011, 107 (11) : 1619 - 1623
  • [8] A novel femoral artery compression device (butterfly compress) versus manual compression for hemostasis after femoral artery puncture: a randomized comparison
    Yi, He
    Peng, Guo
    Xiao Yang, Niu
    Bing, Wang
    Yue, Wang
    Ying, Wang
    Fei, Wu
    MINIMALLY INVASIVE THERAPY & ALLIED TECHNOLOGIES, 2022, 31 (01) : 50 - 57
  • [9] Endovascular Interventions for Peripheral Artery Disease: A Contemporary Review
    Watson, Nathan W.
    Mosarla, Ramya C.
    Secemsky, Eric A.
    CURRENT CARDIOLOGY REPORTS, 2023, 25 (11) : 1611 - 1622
  • [10] Patient Satisfaction After Femoral Arterial Access Site Closure Using the ExoSealA® Vascular Closure Device Compared to Manual Compression: A Prospective Intra-individual Comparative Study
    Pieper, Claus Christian
    Thomas, Daniel
    Nadal, Jennifer
    Willinek, Winfried A.
    Schild, Hans Heinz
    Meyer, Carsten
    CARDIOVASCULAR AND INTERVENTIONAL RADIOLOGY, 2016, 39 (01) : 21 - 27