Evaluation of the corneal topographic characteristics of keratoconus with orbscan II in patients with and without atopy

被引:55
|
作者
Kaya, Vedat
Karakaya, Muharrem
Utine, Canan Asli
Albayrak, Sinan
Oge, Omer Faruk
Yilmaz, Omer Faruk
机构
[1] Yeditepe Univ, Dept Ophthalmol, Istanbul, Turkey
[2] Beyoglu Eye Res & Training Hosp, Istanbul, Turkey
关键词
atopy; corneal topography; keratoconus; Orbscan;
D O I
10.1097/ICO.0b013e3180de1e04
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Purpose: To analyze the differences in corneal topography in keratoconus patients with and without atopy. Methods: In the Beyoglu Eye Research and Training Hospital Refractive Surgery Department, corneal examination with the Orbscan H device (Bausch & Lomb) was done to all patients between May and June 2004 who were diagnosed as keratoconus with corneal topography findings and who did not have any surgical procedure. The atopy grading was done according to the criteria of the UK Atopy Study Group (1994). Patients were divided into 2 groups according to the presence of atopy. The Orbscan findings of the 2 groups were compared. Results: Among 70 keratoconus patients, 33 patients had partial or full atopy. Sixty-six eyes of the 33 patients were classified as the atopic group, whereas 74 eyes of the remaining 37 patients were classified as the control group. The mean age of the patients was 27.7 +/- 9.5 years in the atopic group and 26.9 +/- 9.5 years in the control group. The central corneal thickness was 428.5 +/- 37.1 mu m in the atopic group and 491.8 +/- 56.3 mu m in the control group. There was a statistically significant difference between the mean central and thinnest corneal pachymetric readings, the distance of thinnest point to corneal center, anterior and posterior elevation values, distances of the anterior and posterior elevation to the central cornea, and irregularity indexes in the 2 groups (P < 0.05). Conclusions: This study shows that corneal topographic and pachymetric characteristics of keratoconus may be different in atopic eyes from those in nonatopic eyes. Atopic keratoconus patients could possibly be evaluated as a separate entity in keratoconus disease.
引用
收藏
页码:945 / 948
页数:4
相关论文
共 50 条
  • [1] Evaluation of corneal topography with Orbscan II in first-degree relatives of patients with keratoconus
    Kaya, Vedat
    Utine, Canan Asli
    Altunsoy, Muhsin
    Oral, Deniz
    Yilmaz, Omer Faruk
    CORNEA, 2008, 27 (05) : 531 - 534
  • [2] Prevalence of Orbscan II corneal abnormalities in relatives of patients with keratoconus
    Steele, Timothy M.
    Fabinyi, David C.
    Couper, Terry A.
    Loughnan, Michael S.
    CLINICAL AND EXPERIMENTAL OPHTHALMOLOGY, 2008, 36 (09): : 824 - 830
  • [3] Analysis of incidence of keratoconus in relatives of patients who underwent corneal transplant due to advanced keratoconus using the Orbscan II topographic graphs
    Lopez-Olazagasti, Estela
    Eduardo Hernandez y del Callejo, Cesar
    Ibarra-Galitzia, Jorge
    Ramirez-Zavaleta, Gustavo
    Tepichin, Eduardo
    EIGHTH SYMPOSIUM OPTICS IN INDUSTRY, 2011, 8287
  • [4] The evaluation of corneal topographic parameters with corneal and lens densitometers in pediatric keratoconus
    Selma Urfalıoglu
    Mete Guler
    International Ophthalmology, 2021, 41 : 541 - 548
  • [5] The evaluation of corneal topographic parameters with corneal and lens densitometers in pediatric keratoconus
    Urfalioglu, Selma
    Guler, Mete
    INTERNATIONAL OPHTHALMOLOGY, 2021, 41 (02) : 541 - 548
  • [6] The relationship of corneal topographic parameters with corneal and lens densitometers in patients with keratoconus
    Urfalioglu, Selma
    Ozdemir, Gokhan
    ANNALS OF CLINICAL AND ANALYTICAL MEDICINE, 2020, 11 : 188 - 192
  • [7] Topographic evaluation of relatives of patients with keratoconus
    Karimian, Farid
    Aramesh, Shiela
    Rabei, Hossein Mohammad
    Javadi, Mohammad Ali
    Rafati, Nasrin
    CORNEA, 2008, 27 (08) : 874 - 878
  • [8] EARLY KERATOCONUS DISEASE DETECTION USING ORBSCAN II CORNEAL TOPOGRAPHY
    Lazouni, Mohammed El Amine
    Messadi, Mahamed
    Feroui, Amel
    Mahmoudi, SAiD
    JOURNAL OF MECHANICS IN MEDICINE AND BIOLOGY, 2023, 23 (01)
  • [9] Corneal topographic changes in healthy siblings of patients with keratoconus
    Besharati, Mohammad Reza
    Shoja, Mohammad Reza
    Manaviat, Masoud Reza
    Kheirandish, Maryam
    Rad, Maasome Zare
    INTERNATIONAL JOURNAL OF OPHTHALMOLOGY, 2010, 3 (01) : 73 - 75
  • [10] Repeatability of curvature measurements in central and paracentral corneal areas of keratoconus patients using Orbscan and Pentacam
    Mirzajani, Ali
    Asharlous, Amir
    Kianpoor, Parvin
    Jafarzadehpur, Ebrahim
    Yekta, Abbasali
    Khabazkhoob, Mehdi
    Hashemi, Hassan
    JOURNAL OF CURRENT OPHTHALMOLOGY, 2019, 31 (04): : 382 - 386