Contrast Media in Time-Resolved MRA at 3T: A Systematic Quantitative and Qualitative Analysis of Concentration and Dose Effects on Image Parameters in Minipigs

被引:5
作者
Hadizadeh, Dariusch Reza [1 ]
Keil, Vera Catharina [1 ]
Jost, Gregor [2 ]
Pietsch, Hubertus [2 ]
Weibrecht, Martin [3 ]
Marx, Christian [1 ]
Willinek, Winfried [4 ]
机构
[1] Univ Bonn, Dept Radiol, Sigmund Freud Str 25, D-53113 Bonn, Germany
[2] Bayer AG, MR & CT Contrast Media Res, Berlin, Germany
[3] Philips Technol GmbH Innovat Technol, Res Labs, Aachen, Germany
[4] Krankenhaus Barmherzigen Brueder, Ctr Radiol Neuroradiol Sonog & Nucl Med, Trier, Germany
来源
ROFO-FORTSCHRITTE AUF DEM GEBIET DER RONTGENSTRAHLEN UND DER BILDGEBENDEN VERFAHREN | 2018年 / 190卷 / 08期
关键词
contrast agents; gadobutrol; experimental animal model; magnetic resonance angiography; gadopentetate dimeglumine;
D O I
10.1055/a-0631-4707
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose Quantitative and qualitative analysis of gadopentetate dimeglumine (GD) versus standard-dose (sGb) and halfdose (hGb) gadobutrol in thoracoabdominal time-resolved contrast-enhanced magnetic resonance angiography (4D-MRA) with dynamic computed tomography (dCT) as the quantitative reference in minipigs. Materials and Methods 7 anesthetized Goettingen minipigs received thoracoabdominal dCT (0.37 s rotation time) and transverse 4D-MRA (0.3 s/dynamic frame;) using sGb and hGb. 8 other minipigs received coronal 4D-MRA (1.3 s/dynamic frame; sGb, hGb, SGD). dCT attenuation levels were converted into absolute gadolinium concentrations and compared to 4D-MRA peak signal intensities (SI). Bolus lengths were quantified by full width at half maximum (FWHM) measurements. After this comparison of dose effects on SI in transverse 4D-MRA, coronal 4D-MRAs were analyzed regarding both quantitative and qualitative parameters. Results In dCT (transverse 4D-MRA) hGb showed 39.0 % (14.5 %) lower arterial peak gadolinium concentrations (peak SIs) and 20.6 % (33.8 %) shorter FWHM compared to sGb. The difference was due to peak plateaus or reversals in 4D-MRA in 5/7 animals. While sGb led to the highest peak SIs, image quality ratings of arteries were rated similarly high with all contrast agent protocols despite a slightly higher SI with sGb. In contrast, venous peak SIs and image quality ratings were significantly higher when using sGb. Conclusion Peak Gd concentrations and 4D-MRA peak SIs are highest with sGB. These differences are most evident in the venous phase leading to superior image quality in multiphase 4D-MRA.
引用
收藏
页码:747 / 757
页数:11
相关论文
共 30 条
[1]   Peripheral Arterial Occlusive Disease: Evaluation of a High Spatial and Temporal Resolution 3-T MR Protocol with a Low Total Dose of Gadolinium versus Conventional Angiography [J].
Attenberger, Ulrike I. ;
Haneder, Stefan ;
Morelli, John N. ;
Diehl, Steffen J. ;
Schoenberg, Stefan O. ;
Michaely, Henrik J. .
RADIOLOGY, 2010, 257 (03) :879-887
[2]  
Benner T, 2000, J MAGN RESON IMAGING, V12, P371, DOI 10.1002/1522-2586(200009)12:3<371::AID-JMRI1>3.0.CO
[3]  
2-3
[4]   Arterial first pass gadolinium-CM dynamics as a function of several intravenous saline flush and Gd volumes [J].
Boos, M ;
Scheffler, K ;
Haselhorst, R ;
Reese, E ;
Fröhlich, J ;
Bongartz, GM .
JOURNAL OF MAGNETIC RESONANCE IMAGING, 2001, 13 (04) :568-576
[5]   4D Radial Acquisition Contrast-Enhanced MR Angiography and Intracranial Arteriovenous Malformations Quickly Approaching Digital Subtraction Angiography [J].
Eddleman, Christopher S. ;
Jeong, Hyun J. ;
Hurley, Michael C. ;
Zuehlsdorff, Sven ;
Dabus, Guilherme ;
Getch, Christopher G. ;
Batjer, H. Hunt ;
Bendok, Bernard R. ;
Carroll, Timothy J. .
STROKE, 2009, 40 (08) :2749-2753
[6]   Visualization of Deep Veins and Detection of Deep Vein Thrombosis (DVT) With Balanced Turbo Field Echo (b-TFE) and Contrast-Enhanced T1 Fast Field Echo (CE-FFE) Using a Blood Pool Agent (BPA) [J].
Enden, Tone ;
Storas, Tryggve H. ;
Negard, Anne ;
Haig, Ylva ;
Sandvik, Leiv ;
Gjesdal, Kjell-Inge ;
Sandset, Per Morten ;
Klow, Nils-Einar .
JOURNAL OF MAGNETIC RESONANCE IMAGING, 2010, 31 (02) :416-424
[7]   Contrast-enhanced three-dimensional pulmonary perfusion magnetic resonance imaging - Intraindividual comparison of 1.0 M gadobutrol and 0.5 M Gd-DTPA at three dose levels [J].
Fink, C ;
Puderbach, M ;
Ley, S ;
Plathow, C ;
Bock, M ;
Zuna, I ;
Kauczor, HU .
INVESTIGATIVE RADIOLOGY, 2004, 39 (03) :143-148
[8]   Prevalence of acute adverse reactions to gadobutrol-A highly concentrated macrocyclic gadolinium chelate: Review of 14,299 patients from observational trials [J].
Forsting, Michael ;
Palkowitsch, Petra .
EUROPEAN JOURNAL OF RADIOLOGY, 2010, 74 (03) :E187-E193
[9]   Determination of optimal injection parameters for intraarterial gadolinium-enhanced MR angiography [J].
Frayne, R ;
Omary, RA ;
Unal, O ;
Strother, CM .
JOURNAL OF VASCULAR AND INTERVENTIONAL RADIOLOGY, 2000, 11 (10) :1277-1284
[10]   0.5 M Gd chelate (Magnevist®) versus 1.0 M Gd chelate (Gadovist®):: Dose-independent effect on image quality of pelvic three-dimensional MR-angiography [J].
Goyen, M ;
Lauenstein, TC ;
Herborn, CU ;
Debatin, JF ;
Bosk, S ;
Ruehm, SG .
JOURNAL OF MAGNETIC RESONANCE IMAGING, 2001, 14 (05) :602-607