An update high-temperature superconducting maglev measurement system

被引:90
作者
Wang, Suyu [1 ]
Wang, Jiasu
Deng, Changyan
Lu, Yiyu
Zeng, Youwen
Song, Honghai
Huang, Haiyu
Jing, Hua
Huang, Yonggang
Zheng, Jun
Wang, Xingzhi
Zhang, Ya
机构
[1] SW Jiaotong Univ, Appl Superconduct Lab, Chengdu 610031, Peoples R China
[2] SW Jiaotong Univ, Coll Comp & Commun Engn, Chengdu 610031, Peoples R China
关键词
high-temperature superconductors; maglev; measurement equipment; measurement technology; YBCO bulk;
D O I
10.1109/TASC.2007.899257
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
An update high temperature superconducting Maglev measurement system (SCML-02) was successfully developed. The system includes liquid nitrogen vessel, cylinder permanent magnet (PM) or PM guideway (PMG), data collection and processing, mechanical drive and autocontrol. The liquid nitrogen vessel with high temperature superconductors (HTSCs) can be placed above or under the PM. This measurement system has other characteristics: high measurement precision, instant measurement at movement of the measured HTSCs specimen, synchronous measurement of levitation and guidance, measurement in three dimensions at one time, relaxation measurement of both levitation and guidance force, and so on. In order to calibrate measurement precision and to verify special function of SCML-02, two cylinder PMs are used, which have the same scale and technical specification. The Maglev properties of HTSCs YBCO bulk are measured on the basis of the calibration results of SCML-02. The levitation forces of single YBCO bulk and of seven YBCO bulks above PMG are measured by SCML-02. All functions are validated experimentally. The main specification of the measurement system is: position precision +/- 0.05 nun; vertical force precision 2 parts per thousand; horizontal force precision 1 parts per thousand. The force measurement precision has achieved 0.02 N.
引用
收藏
页码:2067 / 2070
页数:4
相关论文
共 8 条
[1]  
DENG CY, 2006, UNPUB 19 INT S SUP J
[2]   LEVITATION DRIFT OF A MAGNET SUPPORTED BY A HIGH-T-C SUPERCONDUCTOR UNDER VIBRATION [J].
HIKIHARA, T ;
MOON, FC .
PHYSICA C, 1995, 250 (1-2) :121-127
[3]   A PENDULUM FEEDBACK-SYSTEM TO MEASURE THE LATERAL FORCE ON A MAGNET PLACED ABOVE A HIGH-TC SUPERCONDUCTOR [J].
JOHANSEN, TH ;
BRATSBERG, H ;
YANG, Z ;
HELGESEN, G ;
SKJELTORP, AT .
REVIEW OF SCIENTIFIC INSTRUMENTS, 1990, 61 (12) :3827-3829
[4]   DYNAMIC MAGNETIC FORCES IN SUPERCONDUCTING CERAMICS [J].
MOON, FC ;
WENG, KC ;
CHANG, PZ .
JOURNAL OF APPLIED PHYSICS, 1989, 66 (11) :5643-5645
[5]  
RIISE AB, 1995, J APPL PHYS, V234, P108
[6]  
Wang J., 2000, HIGH TECHNOL LETT, V10, P56
[7]  
Wang JS, 2005, FRONTIERS IN SUPERCONDUCTING MATERIALS, P885, DOI 10.1007/3-540-27294-1_24
[8]   The first man-loading high temperature superconducting Maglev test vehicle in the world [J].
Wang, JS ;
Wang, SY ;
Zeng, YW ;
Huang, HY ;
Luo, F ;
Xu, ZP ;
Tang, QX ;
Lin, GB ;
Zhang, CF ;
Ren, ZY ;
Zhao, GM ;
Zhu, DG ;
Wang, SH ;
Jiang, H ;
Zhu, M ;
Deng, CY ;
Hu, PF ;
Li, CY ;
Liu, F ;
Lian, JS ;
Wang, XR ;
Wang, LH ;
Shen, XM ;
Dong, XG .
PHYSICA C-SUPERCONDUCTIVITY AND ITS APPLICATIONS, 2002, 378 :809-814