Comparison of posterior capsule opacification development with 2 single-piece intraocular lens types

被引:14
作者
Leydolt, Christina [1 ]
Schartmueller, Daniel [1 ]
Schwarzenbacher, Luca [1 ]
Schranz, Markus [1 ]
Schriefl, Sabine [1 ]
Menapace, Rupert [1 ]
机构
[1] Med Univ Vienna, Dept Ophthalmol, Waehringer Guertel 18-20, A-1090 Vienna, Austria
关键词
OPTIC EDGE DESIGN; CONTRAST SENSITIVITY; RATES; GLISTENINGS; EYES;
D O I
10.1016/j.jcrs.2017.06.005
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Purpose: To evaluate the differences in the incidence of posterior capsule opacification (PCO) and visual and optical performance between 2 hydrophobic acrylic single-piece sharp-edged intraocular lenses (IOLs) over 3 years. Setting: Department of Ophthalmology, Medical University of Vienna, Vienna, Austria. Design: Prospective randomized case series. Methods: Patients with bilateral cataract were prospectively randomized to receive an Eyecee One IOL (IOL A) or an Acrysof SN6OWF IOL (IOL B) and were followed for 36 months. The corrected distance visual acuity (CDVA) and IOL decentration and tilt were measured. The PCO was quantified by analysis of standardized retroillumination images. Results: The study comprised 160 eyes of 80 patients. The PCO incidence was low for both IOLs at all follow-up visits. Three years postoperatively, the median objective PCO score was 1.4 (range 0 to 5.6) for IOL A and 1.5 (range 0 to 5.0) for IOL B (P = .67). The neodymium:YAG (Nd:YAG) capsulotomy rate 3 years after surgery was 16.4% and 6.0% (P = .06), respectively. Visual acuity and contrast sensitivity outcomes were also comparable at all follow-up visits. Conclusions: Both IOLs showed good capsular bag performance and low PCO rates 3 years after surgery. Both IOLs also showed comparable results for visual acuity, contrast sensitivity, decentration and tilt, PCO score, slitlamp examination, and Nd:YAG capsulotomy rates. (C) 2017 ASCRS and ESCRS
引用
收藏
页码:774 / 780
页数:7
相关论文
共 22 条
[1]   Long-term effect of optic edge design in an acrylic intraocular lens on posterior capsule opacification [J].
Buehl, W ;
Findl, O ;
Menapace, R ;
Sacu, S ;
Kriechbaum, K ;
Koeppl, C ;
Wirtitsch, M .
JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2005, 31 (05) :954-961
[2]   Effect of an acrylic intraocular lens with a sharp posterior optic edge on posterior capsule opacification [J].
Buehl, W ;
Findl, O ;
Menapace, R ;
Rainer, G ;
Sacu, S ;
Kiss, B ;
Petternel, V ;
Georgopoulos, M .
JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2002, 28 (07) :1105-1111
[3]   Reproducibility of standardized retroillumination photography for quantification of posterior capsule opacification [J].
Buehl, W ;
Findl, O ;
Menapace, R ;
Georgopoulos, M ;
Rainer, G ;
Wirtitsch, M ;
Siegl, H ;
Pinz, A .
JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2002, 28 (02) :265-270
[4]   Long-term effect of optic edge design in a silicone intraocular lens on posterior capsule opacification [J].
Buehl, Wolf ;
Menapace, Rupert ;
Findl, Oliver ;
Neumayer, Thomas ;
Bolz, Matthias ;
Prinz, Ana .
AMERICAN JOURNAL OF OPHTHALMOLOGY, 2007, 143 (06) :913-919
[5]   Glistenings 9 years after phacoemulsification in hydrophobic and hydrophilic acrylic intraocular lenses [J].
Chang, Anthony ;
Kugelberg, Maria .
JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2015, 41 (06) :1199-1204
[6]   Comparison of posterior capsule opacification and glistenings with 2 hydrophobic acrylic intraocular lenses: 5-to 7-year follow-up [J].
Chang, Anthony ;
Behndig, Anders ;
Ronbeck, Margrethe ;
Kugelberg, Maria .
JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2013, 39 (05) :694-698
[7]   Posterior capsule opacification and neodymium: YAG capsulotomy rates with AcrySof acrylic and PhacoFlex II silicone intraocular lenses [J].
Ernest, PH .
JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2003, 29 (08) :1546-1550
[8]   Comparison of 4 methods for quantifying posterior capsule opacification [J].
Findl, O ;
Buehl, W ;
Menapace, R ;
Georgopoulos, M ;
Rainer, G ;
Siegl, H ;
Kaider, A ;
Pinz, A .
JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2003, 29 (01) :106-111
[9]   Contrast sensitivity: determining the visual quality and function of cataract, intraocular lenses and refractive surgery [J].
Ginsburg, AR .
CURRENT OPINION IN OPHTHALMOLOGY, 2006, 17 (01) :19-26
[10]   Comparison of posterior capsule opacification rates between hydrophilic and hydrophobic single-viece acrylic intraocular lenses [J].
Heatley, CJ ;
Spalton, DJ ;
Kumar, A ;
Jose, R ;
Boyce, J ;
Bender, LE .
JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2005, 31 (04) :718-724