Active Power Filtering Under Unbalanced and Distorted Grid Conditions Using Modular Fundamental Element Detection Technique

被引:4
|
作者
Hoon, Yap [1 ]
Zainuri, Muhammad Ammirrul Atiqi Mohd [2 ,3 ]
Al-Ogaili, Ali Saadon [4 ]
Al-Masri, Ahmed N. [5 ]
Teh, Jiashen [6 ]
机构
[1] Taylors Univ, Fac Innovat & Technol, Sch Comp Sci & Engn, Subang Jaya 47500, Selangor, Malaysia
[2] Univ Kebangsaan Malaysia, Fac Engn & Built Environm, Dept Elect Elect & Syst Engn, Ukm Bangi 43600, Selangor, Malaysia
[3] Univ Kebangsaan Malaysia, Inst IR 4 0, Ukm Bangi 43600, Selangor, Malaysia
[4] Univ Tenaga Nas, Inst Power Engn IPE, Kajang 43000, Selangor, Malaysia
[5] Amer Univ Emirates, Coll Comp & Informat Technol, Dubai, U Arab Emirates
[6] Univ Sains Malaysia, Sch Elect & Elect Engn, Nibong Tebal 14300, Pulau Pinang, Malaysia
来源
IEEE ACCESS | 2021年 / 9卷
关键词
Power harmonic filters; Harmonic analysis; Power systems; Voltage control; Synchronization; Standards; Process control; Active power filter; adaptability feature; fundamental element detection (FED); harmonics compensation; modularity feature; power electronics; reference current signal;
D O I
10.1109/ACCESS.2021.3101238
中图分类号
TP [自动化技术、计算机技术];
学科分类号
0812 ;
摘要
In this paper, an alternative control technique for producing reference current signal to manage operation of three-phase three-wire parallel-connected active power filter (PAPF) is presented. In the context of generating reference current, time-domain synchronous reference frame (SRF) technique has commonly been recognized to provide the benefit of control simplicity. However, its control structure is rather rigid which restricted its flexibility to be applied in different power system configurations. For instance, SRF technique which is initially designated to work with three-phase system cannot be applied directly to single-phase network without intensive modification to its overall control structure. Hence, in this work, a control technique named as modular fundamental element detection (modular-FED) which exhibits modular structure is proposed, to manage mitigation of harmonic current under unbalanced and/or distorted grid. The design concept of the proposed technique was modeled using MATLAB-Simulink software. Two types of highly nonlinear loads are applied to assess the effectiveness of the proposed modular-FED technique under various unbalanced and/or distorted grids. In-depth comparative analysis with the standard SRF technique is performed to evaluate the benefits of using the proposed technique. The presented simulation findings confirmed superiority of the proposed technique in controlling a PAPF to mitigate harmonics contained in the supply grid.
引用
收藏
页码:107502 / 107518
页数:17
相关论文
共 50 条
  • [31] POWER QUALITY ENHANCEMENT STRATEGY OF MICROGRID UNDER DISTORTED AND UNBALANCED CONDITIONS
    Wang, Ruiqi
    Li, Yunwei
    Zhang, Chenghui
    INTERNATIONAL JOURNAL OF POWER AND ENERGY SYSTEMS, 2015, 35 (03): : 105 - 112
  • [32] A Combined Phase Locked Loop Technique for Grid Synchronization of Power Converters under Highly Distorted Grid Conditions
    Daou, Nizar
    Khatounian, Flavia
    2016 IEEE INTERNATIONAL MULTIDISCIPLINARY CONFERENCE ON ENGINEERING TECHNOLOGY (IMCET), 2016, : 108 - 114
  • [33] Constant Instantaneous Power Based Controller for a Shunt Active Power Filter under Balanced, Unbalanced, and Distorted Supply Conditions
    Khalid, Saifullah
    Dwivedi, Bharti
    Mishra, V. M.
    2015 INTERNATIONAL CONFERENCE ON COMPUTING, COMMUNICATION & AUTOMATION (ICCCA), 2015, : 963 - 967
  • [34] Comparison of Active Power Filter Reference Current Detection Methods under Distorted and Unbalanced PCC Voltages
    Popa, D. L.
    Nicolae, P. M.
    2014 INTERNATIONAL CONFERENCE ON APPLIED AND THEORETICAL ELECTRICITY (ICATE), 2014,
  • [35] Flexible Ripple Minimization Technique for Wind-Solar Renewable Energy System Under Unbalanced and Distorted Grid Conditions
    Das, Souvik
    Singh, Bhim
    IEEE TRANSACTIONS ON INDUSTRY APPLICATIONS, 2022, 58 (05) : 6739 - 6751
  • [36] Integrated Modeling and Enhanced Control of DFIG Under Unbalanced and Distorted Grid Voltage Conditions
    Xu, Hailiang
    Hu, Jiabing
    He, Yikang
    IEEE TRANSACTIONS ON ENERGY CONVERSION, 2012, 27 (03) : 725 - 736
  • [37] Dynamic Modeling and Improved Control of DFIG under Unbalanced and Distorted Grid Voltage Conditions
    Xu, Hailiang
    Hu, Jiabing
    Nian, Heng
    He, Yikang
    2012 IEEE INTERNATIONAL SYMPOSIUM ON INDUSTRIAL ELECTRONICS (ISIE), 2012, : 1579 - 1584
  • [38] Implementation of SOGI-EPLL for DVR Control Under Unbalanced and Distorted Grid Conditions
    Abhishek Panchal
    Ashish Jaglan
    Sumit Saroha
    Pardeep Singla
    Sumit Kumar Maitra
    Smart Grids and Sustainable Energy, 10 (1)
  • [39] Comparison of reference current generation techniques for non-active power compensation under distorted and unbalanced conditions
    Ordonez, Rafael
    Karimi, Charif
    Oueidat, Mohamad
    Sadarnac, Daniel
    IECON 2006 - 32ND ANNUAL CONFERENCE ON IEEE INDUSTRIAL ELECTRONICS, VOLS 1-11, 2006, : 1680 - +
  • [40] A grid-tie PV inverter with the ability to improve power quality under unbalanced and distorted source voltage conditions
    Afkar, Hadi
    Shamsinejad, Mohammad Ali
    Ebadian, Mahmoud