Measurements of PEM conductivity by impedance spectroscopy

被引:55
|
作者
Mikhailenko, S. D. [1 ]
Guiver, M. D. [2 ]
Kaliaguine, S. [1 ]
机构
[1] Univ Laval, Dept Chem Engn, Quebec City, PQ G1K 7P4, Canada
[2] Natl Res Council Canada, Inst Chem Proc & Environm Technol, Ottawa, ON K1A 0R6, Canada
基金
加拿大自然科学与工程研究理事会;
关键词
proton conductivity; PEM; impedance spectroscopy;
D O I
10.1016/j.ssi.2008.04.020
中图分类号
O64 [物理化学(理论化学)、化学物理学];
学科分类号
070304 ; 081704 ;
摘要
The methodology of PEM conductivity measurements is discussed for examples of literature data and results of the experiments, carried out in this study. It is shown here that a simple two-electrode cell proposed in this work, operated at frequencies of 1 to 10(7) Hz reproducibly gives a response typical for a solid electrolyte, and therefore is easily rationalised in terms of equivalent Circuits. The obtained impedance diagrams are compared with the ones described in the literature for 4-probe experiments. It appears from this comparison that the cell geometry and electrode arrangement play important roles in the formation of the frequency dependent response. In some cases, two-electrode cells may have an advantage over the four-probe technique, as they are less complicated and therefore involve less stray effects ill the resulting impedance spectra. In this study, the proposed configuration, which we have previously utilized for some of our measurements, proved to be efficient at producing reproducible, reasonable and reliable results, related to the expected values of PEM conductivity. (c) 2008 Elsevier B.V. All rights reserved.
引用
收藏
页码:619 / 624
页数:6
相关论文
共 50 条
  • [31] Impedance spectroscopy studies of proton conductivity in imidazolium malonate
    Lawniczak, Pawel
    Pogorzelec-Glaser, Katarzyna
    Pietraszko, Adam
    Hilczer, Boena
    SOLID STATE IONICS, 2017, 306 : 25 - 30
  • [32] CONDUCTIVITY CELL FOR COUPLED IMPEDANCE AND RAMAN-SPECTROSCOPY
    LORIDANT, S
    BONNAT, M
    SIEBERT, E
    APPLIED SPECTROSCOPY, 1995, 49 (08) : 1193 - 1196
  • [33] Conductivity of polymer electrolyte membranes by impedance spectroscopy with microelectrodes
    Kelly, MJ
    Egger, B
    Fafilek, G
    Besenhard, JO
    Kronberger, H
    Nauer, GE
    SOLID STATE IONICS, 2005, 176 (25-28) : 2111 - 2114
  • [34] Impedance spectroscopy on non-conventional conductivity cells
    Hopirtean, E.
    Mihalcioiu, F.
    Forizs, E.
    Kormos, F.
    Sensors and Actuators, B: Chemical, 1994, B19 (1 -3 pt 2) : 389 - 391
  • [35] Investigation on conductivity anomalies in ferrites using impedance spectroscopy
    Kumar, N. S. K.
    Shahid, T. S.
    Govindaraj, G.
    Results in Physics, 2016, 6 : 824 - 825
  • [36] Conductivity assessment of multifunctional cement pastes by impedance spectroscopy
    Diaz, Belen
    Guitian, Beatriz
    Novoa, X. Ramon
    Perez, Carmen
    CORROSION SCIENCE, 2021, 185
  • [37] Variation of PEM Fuel Cell Physical Parameters with Current: Impedance Spectroscopy Study
    Reshetenko, Tatyana
    Kulikovsky, Andrei
    JOURNAL OF THE ELECTROCHEMICAL SOCIETY, 2016, 163 (09) : F1100 - F1106
  • [38] Simultaneous electrochemical impedance spectroscopy of single cells in a PEM fuel cell stack
    Hakenjos, A
    Zobel, M
    Clausnitzer, J
    Hebling, C
    JOURNAL OF POWER SOURCES, 2006, 154 (02) : 360 - 363
  • [39] Electrochemical Pressure Impedance Spectroscopy for PEM Fuel Cells: Are the Measured Spectra Unique?
    Kulikovsky, Andrei
    JOURNAL OF THE ELECTROCHEMICAL SOCIETY, 2022, 169 (09)
  • [40] TEMPERATURE SENSITIVITY ANALYSIS OF ELECTROCHEMICAL IMPEDANCE SPECTROSCOPY RESULTS IN PEM FUEL CELLS
    Niya, Seyed Mohammad Rezaei
    Hoorfar, Mina
    PROCEEDINGS OF THE ASME 10TH FUEL CELL SCIENCE, ENGINEERING, AND TECHNOLOGY CONFERENCE, 2012, 2012, : 345 - 349