How to assess intra- and inter-observer agreement with quantitative PET using variance component analysis: a proposal for standardisation

被引:16
|
作者
Gerke, Oke [1 ,2 ]
Vilstrup, Mie Holm [1 ]
Segtnan, Eivind Antonsen [1 ]
Halekoh, Ulrich [3 ]
Hoilund-Carlsen, Poul Flemming [1 ,4 ]
机构
[1] Odense Univ Hosp, Dept Nucl Med, Sdr Blvd 29, DK-5000 Odense C, Denmark
[2] Univ Southern Denmark, Ctr Hlth Econ Res, Campusvej 55, DK-5230 Odense M, Denmark
[3] Univ Southern Denmark, Epidemiol Biostat & Biodemog, JB Winslows Vej 9b, DK-5000 Odense C, Denmark
[4] Univ Southern Denmark, Dept Clin Res, Winslowparken 19, DK-5000 Odense C, Denmark
来源
BMC MEDICAL IMAGING | 2016年 / 16卷
关键词
Bland-Altman limits of agreement; Intra-observer; Inter-observer; Intraobserver; Interobserver; Intra-rater; Inter-rater; Repeatability coefficient; Sample size; Standardised uptake value; FDG-PET/CT; BLOOD-FLOW; REPEATABILITY; F-18-FDG; EVENTS; REPRODUCIBILITY; RELIABILITY; GUIDELINES; TRACER;
D O I
10.1186/s12880-016-0159-3
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Background: Quantitative measurement procedures need to be accurate and precise to justify their clinical use. Precision reflects deviation of groups of measurement from another, often expressed as proportions of agreement, standard errors of measurement, coefficients of variation, or the Bland-Altman plot. We suggest variance component analysis (VCA) to estimate the influence of errors due to single elements of a PET scan (scanner, time point, observer, etc.) to express the composite uncertainty of repeated measurements and obtain relevant repeatability coefficients (RCs) which have a unique relation to Bland-Altman plots. Here, we present this approach for assessment of intra- and inter-observer variation with PET/CT exemplified with data from two clinical studies. Methods: In study 1, 30 patients were scanned pre-operatively for the assessment of ovarian cancer, and their scans were assessed twice by the same observer to study intra-observer agreement. In study 2, 14 patients with glioma were scanned up to five times. Resulting 49 scans were assessed by three observers to examine inter-observer agreement. Outcome variables were SUVmax in study 1 and cerebral total hemispheric glycolysis (THG) in study 2. Results: In study 1, we found a RC of 2.46 equalling half the width of the Bland-Altman limits of agreement. In study 2, the RC for identical conditions (same scanner, patient, time point, and observer) was 2392; allowing for different scanners increased the RC to 2543. Inter-observer differences were negligible compared to differences owing to other factors; between observer 1 and 2: -10 (95 % CI: -352 to 332) and between observer 1 vs 3: 28 (95 % CI: -313 to 370). Conclusions: VCA is an appealing approach for weighing different sources of variation against each other, summarised as RCs. The involved linear mixed effects models require carefully considered sample sizes to account for the challenge of sufficiently accurately estimating variance components.
引用
收藏
页数:9
相关论文
共 27 条
  • [21] Transrectal three-dimensional fetal volumetry and crown-rump length measurement during early gestation in mares: Intra- and inter-observer reliability and agreement
    Becsek, Angela
    Tzanidakis, Nikolaos
    Blanco, Miguel
    Bollwein, Heinrich
    THERIOGENOLOGY, 2019, 126 : 266 - 271
  • [22] Intra- and inter-observer reproducibility study of gestational age estimation using three common foetal biometric parameters: Experienced versus inexperienced sonographer
    Ohagwu, C. C.
    Onoduagu, H. I.
    Eze, C. U.
    Ochie, K.
    Ohagwu, C. I.
    RADIOGRAPHY, 2015, 21 (01) : 54 - 60
  • [23] How stable is quantitative MRI? - Assessment of intra- and inter-scanner-model reproducibility using identical acquisition sequences and data analysis programs
    Gracien, Rene-Maxime
    Maiworm, Michelle
    Brueche, Nadine
    Shrestha, Manoj
    Noeth, Ulrike
    Hattingen, Elke
    Wagner, Marlies
    Deichmann, Ralf
    NEUROIMAGE, 2020, 207
  • [24] Intra- and inter-observer reliability of quantitative analysis of the infra-patellar fat pad and comparison between fat- and non-fat-suppressed imaging-Data from the osteoarthritis initiative
    Steidle-Kloc, E.
    Wirth, W.
    Ruhdorfer, A.
    Dannhauer, T.
    Eckstein, F.
    ANNALS OF ANATOMY-ANATOMISCHER ANZEIGER, 2016, 204 : 29 - 35
  • [25] Intra- and inter-observer reproducibility of volume measurement of knee cartilage segmented from the OAI MR image set using a novel semi-automated segmentation method
    Bae, K. T.
    Shim, H.
    Tao, C.
    Chang, S.
    Wang, J. H.
    Boudreau, R.
    Kwoh, C. K.
    OSTEOARTHRITIS AND CARTILAGE, 2009, 17 (12) : 1589 - 1597
  • [26] Skeletal age assessed by TW2 using 20-bone, carpal and RUS score systems: Intra-observer and inter-observer agreement among male pubertal soccer players
    Sousa-e-Silva, Paulo
    Coelho-e-Silva, Manuel J.
    Seabra, Andre
    Costa, Daniela C.
    Martinho, Diogo, V
    Duarte, Joao P.
    Oliveira, Tomas
    Goncalves-Santos, Joao
    Rodrigues, Ines
    Ribeiro, Luis P.
    Figueiredo, Antonio J.
    Konarski, Jan M.
    Cumming, Sean P.
    Malina, Robert M.
    PLOS ONE, 2022, 17 (08):
  • [27] Intra- and inter-operator repeatability of myocardial blood flow and myocardial flow reserve measurements using rubidium-82 pet and a highly automated analysis program
    Klein, Ran
    Renaud, Jennifer M.
    Ziadi, Maria C.
    Thorn, Stephanie L.
    Adler, Andy
    Beanlands, Rob S.
    deKemp, Robert A.
    JOURNAL OF NUCLEAR CARDIOLOGY, 2010, 17 (04) : 600 - 616