Surface plasmon resonance biosensor with high anti-fouling ability for the detection of cardiac marker troponin T

被引:51
|
作者
Liu, Jen Tsai [1 ]
Chen, Ching Jung [2 ]
Ikoma, Toshiyuki [3 ]
Yoshioka, Tomohiko [3 ]
Cross, Jeffrey S. [4 ,5 ]
Chang, Shwu-Jen [1 ]
Tsai, Jang-Zern [2 ]
Tanaka, Junzo [3 ]
机构
[1] I Shou Univ, Dept Biomed Engn, Kaohsiung 82445, Taiwan
[2] Natl Cent Univ, Dept Elect Engn, Jhongli 32001, Taoyuan County, Taiwan
[3] Tokyo Inst Technol, Dept Met & Ceram Sci, Meguro Ku, Tokyo 1528552, Japan
[4] Tokyo Inst Technol, Dept Engn Fundamentals & Strateg Planning, Meguro Ku, Tokyo 1528552, Japan
[5] Tokyo Inst Technol, Dept Mech Sci & Engn, Meguro Ku, Tokyo 1528552, Japan
关键词
Myocardial infarction; Troponin T; Anti-fouling ability; Surface plasmon resonance; Self-assembled monolayer; Oligoethylene glycol; SELF-ASSEMBLED MONOLAYERS; MOLECULAR-CONFORMATION; SPR IMMUNOSENSOR; MODEL SYSTEM; ADSORPTION; PROTEIN; GOLD; RESIST; ACID; BLOOD;
D O I
10.1016/j.aca.2011.07.019
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Designing a surface recognition layer with high anti-fouling ability, high affinity, and high specificity is an important issue to produce high sensitivity biosensing transducers. In this study, a self-assembled monolayer (SAM) consisting of a homogeneous mixture of oligo(ethylene glycol) (OEG)-terminated alkanethiolate and mercaptohexadecanoic acid (MHDA) on Au was employed for immobilizing troponin T antibody and applied in detecting cardiac troponin T by using surface plasmon resonance (SPR). The mixed SAM showed no phase segregation and exhibited human serum albumin resistance, particularly with an antibody-immobilized surface. X-ray photoemission spectra revealed that the chemical composition ratio of OEG to the mixed SAM was 69% and the OEG packing density was 82%. The specific binding of troponin Ton the designed surface indicated a good linear correlation (R = 0.991, P < 0.0009) at concentrations lower than 50 mu g mL(-1) with the limit of detection of 100 ng mL(-1) using a SPR measuring instrument. It is concluded that the mixed SAM functions as designed since it has high detection capability. high accuracy and reproducibility, as well as shows strong potential to be applied in rapid clinical diagnosis for label-free detection within 2 min. (C) 2011 Elsevier B.V. All rights reserved.
引用
收藏
页码:80 / 86
页数:7
相关论文
共 50 条
  • [1] Wavelength modulation based surface plasmon resonance sensor for detection of cardiac marker proteins troponin I and troponin T
    Sinha, Rajeev K.
    SENSORS AND ACTUATORS A-PHYSICAL, 2021, 332 (332)
  • [2] Surface plasmon resonance-based DNA biosensor for arsenic trioxide detection
    Solanki, Pratima R.
    Prabhakar, Nirmal
    Pandey, Manoj K.
    Malhotra, Bansi D.
    INTERNATIONAL JOURNAL OF ENVIRONMENTAL ANALYTICAL CHEMISTRY, 2009, 89 (01) : 49 - 57
  • [3] An optical biosensor based on surface plasmon resonance for determination of human cardiac troponin I
    Song, DQ
    Liu, X
    Zhao, LW
    Zhang, HQ
    Wei, JY
    Mu, Y
    Luo, GM
    CHEMICAL JOURNAL OF CHINESE UNIVERSITIES-CHINESE, 2003, 24 (07): : 1185 - 1188
  • [4] Surface plasmon resonance biosensors for early troponin detection
    Ranjbari, Faride
    Nosrat, Ali
    Fathi, Farzaneh
    Mohammadzadeh, Alireza
    CLINICA CHIMICA ACTA, 2024, 558
  • [5] Surface plasmon resonance biosensor for microalbumin detection
    Liu, Jen-Tsai
    Lin, Po-Shen
    Hsin, Yue-Ming
    Tsai, Jang-Zern
    Chen, Wen-Yih
    JOURNAL OF THE TAIWAN INSTITUTE OF CHEMICAL ENGINEERS, 2011, 42 (05) : 696 - 700
  • [6] Surface plasmon resonance biosensor for the detection of ochratoxin A in cereals and beverages
    Yuan, Jing
    Deng, Dawei
    Lauren, Denis R.
    Aguilar, Marie-Isabel
    Wu, Yinqiu
    ANALYTICA CHIMICA ACTA, 2009, 656 (1-2) : 63 - 71
  • [7] Biosensor platform for parallel surface plasmon-enhanced epifluorescence and surface plasmon resonance detection
    Reiner, Agnes T.
    Fossati, Stefan
    Dostalek, Jakub
    SENSORS AND ACTUATORS B-CHEMICAL, 2018, 257 : 594 - 601
  • [8] Surface plasmon resonance biosensor for the detection of VEGFR-1-a protein marker of myelodysplastic syndromes
    Pimkova, Kristyna
    Bockova, Marketa
    Hegnerova, Katerina
    Suttnar, Jiri
    Cermak, Jaroslav
    Homola, Jiri
    Dyr, Jan E.
    ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2012, 402 (01) : 381 - 387
  • [9] Surface plasmon resonance biosensor for the detection of VEGFR-1—a protein marker of myelodysplastic syndromes
    Kristýna Pimková
    Markéta Bocková
    Kateřina Hegnerová
    Jiří Suttnar
    Jaroslav Čermák
    Jiří Homola
    Jan E. Dyr
    Analytical and Bioanalytical Chemistry, 2012, 402 : 381 - 387
  • [10] Surface plasmon resonance biosensor for environmental detection of tramadol
    Capkova, Magdalena
    Hemmerova, Erika
    Homola, Jiri
    ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2025, : 2859 - 2865