Application of a handheld X-ray fluorescence analyzer for the quantification of air particulate matter on Teflon filters

被引:7
|
作者
Chatoutsidou, Sofia Eirini [1 ]
Papagiannis, Stefanos [2 ,3 ,4 ]
Anagnostopoulos, Dimitrios F. [3 ]
Eleftheriadis, Konstantinos [4 ]
Lazaridis, Mihalis [1 ]
Karydas, Andreas G. [2 ]
机构
[1] Tech Univ Crete, Sch Chem & Environm Engn, Khania 73100, Greece
[2] NCSR Demokritos, Inst Nucl & Particle Phys, Athens 15310, Greece
[3] Univ Ioannina, Dept Mat Sci & Engn, Ioannina 45110, Greece
[4] NCSR Demokritos, Environm Radioact Lab, INRASTES, Athens 15310, Greece
关键词
Handheld ED-XRF spectrometer; Optimization; Particulate matter; Elemental quantification; SOURCE APPORTIONMENT; ELEMENTAL ANALYSIS; TOXIC METALS; AEROSOL; VALIDATION; SAMPLES; LEAD; SPECTROMETER; SIZE;
D O I
10.1016/j.sab.2022.106517
中图分类号
O433 [光谱学];
学科分类号
0703 ; 070302 ;
摘要
Elemental characterization of air particulate matter samples through the application of X-ray fluorescence (XRF) spectrometry is a widespread analytical technique. This work presents the optimization and calibration methodology of a handheld XRF spectrometer and its subsequent application in elemental quantification of unknown particulate matter samples. The optimization of the handheld spectrometer was conducted through investigation of the elemental sensitivities and Limits of Detection (LoD) at variable excitation conditions (voltage, filter). Accordingly, five optimum operating conditions were obtained each one targeted in different elemental range: 1) Z = 11-12, 2) 12 < Z < 17, 3) 16 < Z < 23, 4) 22 < Z < 31 and 5) 30 < Z < 92. Subsequently, a number of reference (5 multi-element and 42 compound/single-element) materials were used to obtain calibration curves for 24 elements (Na, Mg, Al, Si, P, S, Cl, K, Ca, Ti, V, Cr, Mn, Fe, Co, Ni, Cu, Zn, As, Se, Br, Rb, Sr, Pb). Weighted least-square regression analysis was implemented to best fit the experimentally measured intensities with mass loadings resulting for most of the elements to high correlations (Pearson r > 0.98) and low statistical error. In addition, intercomparison of the elemental concentrations from 28 unknown particulate matter samples between the handheld and a benchtop XRF spectrometer showed good agreement.
引用
收藏
页数:9
相关论文
共 50 条
  • [1] X-ray fluorescence analysis of air particulate matter generated at a welding site
    Ghosh, M.
    Biswas, S.
    Swain, K. K.
    SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 2022, 187
  • [2] Comparison of multiple X-ray fluorescence techniques for elemental analysis of particulate matter collected on air filters
    Bilo, Fabjola
    Borgese, Laura
    Wambui, Anne
    Assi, Ahmad
    Zacco, Annalisa
    Federici, Stefania
    Eichert, Diane M.
    Tsuji, Kouichi
    Lucchini, Roberto G.
    Placidi, Donatella
    Bontempi, Elza
    Depero, Laura E.
    JOURNAL OF AEROSOL SCIENCE, 2018, 122 : 1 - 10
  • [3] Analysis of Salts and Salt Substitutes with a Handheld X-Ray Fluorescence Analyzer
    Barakat, Anthony
    Maurice, Shelby
    Roberts, Cameron
    Benvenuto, Mark A.
    Roberts-Kirchhoff, Elizabeth S.
    TRACE MATERIALS IN AIR, SOIL, AND WATER, 2015, 1210 : 101 - 114
  • [4] The assessment of a method for measurements and lead quantification in air particulate matter using total reflection X-ray fluorescence spectrometers
    Borgese, Laura
    Bilo, Fabjola
    Zacco, Annalisa
    Federici, Stefania
    Mutahi, Anne Wambui
    Bontempi, Elza
    Trzepla, Krystyna
    Hyslop, Nicole
    Yatkin, Sinan
    Wobrauschek, Peter
    Prost, Joseph
    Ingerle, Dieter
    Depero, Laura E.
    SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 2020, 167 (167)
  • [5] Analysis of metals in particulate matter suspended in air by total reflection x-ray fluorescence
    Almeida, Ana Paula F.
    Santos, Ramon S. S.
    Ferreira, Gabriel C. C.
    Nardes, Raysa C. C.
    Sanches, Francis. A. C. R. A.
    Gama Filho, Hamilton. S.
    Leitao, Roberta G. G.
    Anjos, Marcelino J. J.
    Lopes, Ricardo T. T.
    Oliveira, Davi F. F.
    X-RAY SPECTROMETRY, 2023, 52 (06) : 423 - 429
  • [6] Elemental analysis of particulate matter by X-ray fluorescence methods: A green approach to air quality monitoring
    Bilo, Fabjola
    Cirelli, Paola
    Borgese, Laura
    TRAC-TRENDS IN ANALYTICAL CHEMISTRY, 2024, 170
  • [7] Reliable compositional analysis of airborne particulate matter beyond the quantification limits of total reflection X-ray fluorescence
    Kayser, Yves
    Osan, Janos
    Hoenicke, Philipp
    Beckhoff, Burkhard
    ANALYTICA CHIMICA ACTA, 2022, 1192
  • [8] Elemental stoichiometry of marine particulate matter measured by wavelength dispersive X-ray fluorescence (WDXRF) spectroscopy
    Paulino, A. I.
    Heldal, M.
    Norland, S.
    Egge, J. K.
    JOURNAL OF THE MARINE BIOLOGICAL ASSOCIATION OF THE UNITED KINGDOM, 2013, 93 (08) : 2003 - 2014
  • [9] Performance evaluation of an online monitor based on X-ray fluorescence for detecting elemental concentrations in ambient particulate matter
    Trebs, Ivonne
    Lett, Celine
    Krein, Andreas
    Kawaguchi, Erika Matsumoto
    Junk, Juergen
    ATMOSPHERIC MEASUREMENT TECHNIQUES, 2024, 17 (23) : 6791 - 6805
  • [10] X-RAY-FLUORESCENCE AND QUANTITATIVE PARTICULATE MATTER ANALYSIS
    DECHATEAUBOURG, P
    QUISEFIT, JP
    GARIVAIT, S
    STEINER, E
    GOYON, C
    ANALUSIS, 1993, 21 (06) : 293 - 298