Open technique for supra-acetabular pin placement in pelvic external fixation: a cadaveric study

被引:5
作者
Chumchuen, Sukanis [1 ]
Lertpullpol, Wissarut [1 ]
Apivatgaroon, Adinun [1 ]
机构
[1] Thammasat Univ, Fac Med, Dept Orthopaed, 99 Moo 18, Khlong Nueng 12120, Pathumthani, Thailand
关键词
Open technique; Supra-acetabular pin; Pelvic external fixation; Human cadaver; FEMORAL CUTANEOUS NERVE; HALF-PINS;
D O I
10.1186/s10195-022-00635-w
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Background Standard supra-acetabular pin placement still needs fluoroscopic guidance, which is technically demanding for an untrained surgeon due to the unfamiliar fluoroscopic view and the risk of damaging some structures. The risks associated with the open technique without fluoroscopy have not yet been investigated, despite the palpable entry point and large bony corridor for rapid insertion in the limited time available for the management of unstable pelvic fracture patients. The aim of this study was to compare the open technique without fluoroscopy to the fluoroscopically assisted percutaneous technique for the positioning of supra-acetabular screws in cadavers without pelvic instability. Materials and methods The open technique for half-pin placement was compared to standard fluoroscopic guidance in 16 hemipelves (8 cadavers). The open technique was first performed on one side in each cadaver after simple randomization, followed by standard fluoroscopic guidance on the other side. In the open technique group, a Schanz pin 5 mm in diameter and 200 mm in length was inserted in the area just above the anteroinferior iliac spine (AIIS) and aimed with a medial inclination of 20 degrees and a cephalad inclination of 10-20 degrees after a 2 cm pilot drill hole had been established. Standard fluoroscopically guided pin placement was performed on the other side. Fluoroscopic assessment was conducted after final pin placement on both sides. The lateral femoral cutaneous nerve of the thigh (LFCN) and the hip capsule were identified via the Smith-Peterson approach. After complete dissection of soft tissue, it was clearly apparent that pin penetration was conducted outside the bony corridor. Results The LFCN was found to be in a risk zone near the pin (mean distance, 15 mm; range, 0-30 mm). One LFCN may have been injured in the fluoroscopic guidance group. The mean medial inclination of the pin was 19.8 degrees (range, 5-40 degrees) and the mean cephalad inclination was 11.5 degrees (range 0-20 degrees) in the open technique group. The mean medial inclination of the pin was 30.4 degrees (range, 20-45 degrees) and the mean cephalad inclination was 19.3 degrees (range, 2-35 degrees) in the fluoroscopic guidance group. The mean distance of the pin entry point from the AIIS was 11.1 mm (range, 0-35 mm) in the open technique group. The mean distance of the entry point of the pin from the AIIS was 15.1 mm (range, 0-25 mm) in the fluoroscopic guidance group. The mean hip joint capsule distance was 12 mm (range, 8-25 mm). No joint penetration was observed in the open technique group, compared to one joint penetration in the fluoroscopic guidance group. No sciatic notch penetration was found in either group, but pin penetration outside the external cortex of the ilium was found only in the open technique group, in 4 hemipelves. Conclusions This study shows that the freehand technique performed by experienced trauma surgeons may be as acceptable as controlled pin insertion under image intensification for selecting the proper entry point and stabilizing the anterior pelvic ring.
引用
收藏
页数:8
相关论文
共 15 条
[1]   Effectiveness of non invasive external pelvic compression: a systematic review of the literature [J].
Bakhshayesh, Peyman ;
Boutefnouchet, Tarek ;
Totterman, Anna .
SCANDINAVIAN JOURNAL OF TRAUMA RESUSCITATION & EMERGENCY MEDICINE, 2016, 24
[2]   Peri-acetabular external fixation for hip disease: an anatomical study [J].
Brown, Shaun ;
Lasrado, Irwin ;
Donnan, Leo .
STRATEGIES IN TRAUMA AND LIMB RECONSTRUCTION, 2007, 2 (2-3) :69-75
[3]   Ultrasound-guided supra-acetabular pin placement in pelvic external fixation: description of a surgical technique and results [J].
Chana-Rodriguez, Francisco ;
Cuervas-Mons, Manuel ;
Rojo-Manaute, Jose ;
Mora, Felix ;
Arnal, Juan ;
Vaquero-Martin, Javier .
INJURY-INTERNATIONAL JOURNAL OF THE CARE OF THE INJURED, 2017, 48 :S66-S74
[4]   Pelvic trauma: WSES classification and guidelines [J].
Coccolini, Federico ;
Stahel, Philip F. ;
Montori, Giulia ;
Biffl, Walter ;
Horer, Tal M. ;
Catena, Fausto ;
Kluger, Yoram ;
Moore, Ernest E. ;
Peitzman, Andrew B. ;
Ivatury, Rao ;
Coimbra, Raul ;
Fraga, Gustavo Pereira ;
Pereira, Bruno ;
Rizoli, Sandro ;
Kirkpatrick, Andrew ;
Leppaniemi, Ari ;
Manfredi, Roberto ;
Magnone, Stefano ;
Chiara, Osvaldo ;
Solaini, Leonardo ;
Ceresoli, Marco ;
Allievi, Niccolo ;
Arvieux, Catherine ;
Velmahos, George ;
Balogh, Zsolt ;
Naidoo, Noel ;
Weber, Dieter ;
Abu-Zidan, Fikri ;
Sartelli, Massimo ;
Ansaloni, Luca .
WORLD JOURNAL OF EMERGENCY SURGERY, 2017, 12
[5]   Stabilization of unstable pelvic fractures with supraacetabular compression external fixation [J].
Gardner, Michael J. ;
Nork, Sean E. .
JOURNAL OF ORTHOPAEDIC TRAUMA, 2007, 21 (04) :269-273
[6]   Lateral femoral cutaneous nerve - An anatomic study [J].
Grothaus, MC ;
Holt, M ;
Mekhail, AO ;
Ebraheim, NA ;
Yeasting, RA .
CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 2005, (437) :164-168
[7]   Placement of half-pins for supra-acetabular external fixation: An anatomic study [J].
Haidukewych, GJ ;
Kumar, S ;
Prpa, B .
CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 2003, (411) :269-273
[8]  
Judd Kyle T, 2009, Iowa Orthop J, V29, P124
[9]   Effect of pin location on stability of pelvic external fixation [J].
Kim, WY ;
Hearn, TC ;
Seleem, O ;
Mahalingam, E ;
Stephen, D ;
Tile, M .
CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 1999, (361) :237-244
[10]   Optimal pin position in supraacetabular external fixation [J].
Krassnig, Renate ;
Hohenberger, Gloria M. ;
Schimmerl, Paul ;
Schwarz, Angelika ;
Pichler, Wolfgang ;
Puchwein, Paul ;
Wildburger, Renate .
ANZ JOURNAL OF SURGERY, 2021, 91 (04) :680-684