Peptide immobilisation on porous silicon surface for metal ions detection

被引:14
作者
Sam, Sabrina S. [1 ]
Chazalviel, Jean-Noel J. N. [2 ]
Gouget-Laemmel, Anne Chantal A. C. [2 ]
Ozanam, Francois F. [2 ]
Etcheberry, Arnaud A. [3 ]
Gabouze, Nour-eddine N. [1 ]
机构
[1] UDTS, Algiers, Algeria
[2] Ecole Polytech, CNRS, F-91128 Palaiseau, France
[3] Inst Lavoisier Versailles, CNRS, UMR 8180, Versailles, France
来源
NANOSCALE RESEARCH LETTERS | 2011年 / 6卷
关键词
MODIFIED GOLD ELECTRODES; MONOLAYERS; ADSORPTION; BIOSENSORS; WATER; DERIVATIZATION; BIOMOLECULES; VOLTAMMETRY; ATTACHMENT; CHEMISTRY;
D O I
10.1186/1556-276X-6-412
中图分类号
TB3 [工程材料学];
学科分类号
0805 ; 080502 ;
摘要
In this work, a Glycyl-Histidyl-Glycyl-Histidine (GlyHisGlyHis) peptide is covalently anchored to the porous silicon PSi surface using a multi-step reaction scheme compatible with the mild conditions required for preserving the probe activity. In a first step, alkene precursors are grafted onto the hydrogenated PSi surface using the hydrosilylation route, allowing for the formation of a carboxyl-terminated monolayer which is activated by reaction with N-hydroxysuccinimide in the presence of a peptide-coupling carbodiimide N-ethyl-N'-(3-dimethylaminopropyl)carbodiimide and subsequently reacted with the amino linker of the peptide to form a covalent amide bond. Infrared spectroscopy (FT-IR) and X-ray photoelectron spectroscopy are used to investigate the different steps of functionalization. The property of peptides to form stable complexes with metal ions is exploited to achieve metal-ion recognition by the peptide-modified PSi-based biosensor. An electrochemical study of the GlyHisGlyHis-modified PSi electrode is achieved in the presence of copper ions. The recorded cyclic voltammograms show a quasi-irreversible process corresponding to the Cu(II)/Cu(I) couple. The kinetic factors (the heterogeneous rate constant and the transfer coefficient) and the stability constant of the complex formed on the porous silicon surface are determined. These results demonstrate the potential role of peptides grafted on porous silicon in developing strategies for simple and fast detection of metal ions in solution.
引用
收藏
页码:1 / 8
页数:8
相关论文
共 28 条
  • [1] [Anonymous], J ELECTROCHEM SOC
  • [2] Formation of tetra(ethylene oxide) terminated Si-C linked monolayers and their derivatization with glycine:: An example of a generic strategy for the immobilization of biomolecules on silicon
    Böcking, T
    Kilian, KA
    Hanley, T
    Ilyas, S
    Gaus, K
    Gal, M
    Gooding, JJ
    [J]. LANGMUIR, 2005, 21 (23) : 10522 - 10529
  • [3] Optical biosensors
    Borisov, Sergey M.
    Wolfbeis, Otto S.
    [J]. CHEMICAL REVIEWS, 2008, 108 (02) : 423 - 461
  • [4] Organometallic chemistry on silicon and germanium surfaces
    Buriak, JM
    [J]. CHEMICAL REVIEWS, 2002, 102 (05) : 1271 - 1308
  • [5] Analytical performance and characterization of MPA-Gly-Gly-His modified sensors
    Chow, E
    Wong, ELS
    Böcking, T
    Nguyen, QT
    Hibbert, DB
    Gooding, JJ
    [J]. SENSORS AND ACTUATORS B-CHEMICAL, 2005, 111 : 540 - 548
  • [6] Voltammetric detection of cadmium ions at glutathione-modified gold electrodes
    Chow, E
    Hibbert, DB
    Gooding, JJ
    [J]. ANALYST, 2005, 130 (06) : 831 - 837
  • [7] Detection of heavy metal ions in drinking water using a high-resolution differential surface plasmon resonance sensor
    Forzani, ES
    Zhang, HQ
    Chen, W
    Tao, NJ
    [J]. ENVIRONMENTAL SCIENCE & TECHNOLOGY, 2005, 39 (05) : 1257 - 1262
  • [8] Covalent attachment and derivatization of poly(L-lysine) monolayers on gold surfaces as characterized by polarization-modulation FT-IR spectroscopy
    Frey, BL
    Corn, RM
    [J]. ANALYTICAL CHEMISTRY, 1996, 68 (18) : 3187 - 3193
  • [9] Reaction of porous silicon with both end-functionalized organic compounds bearing ω-bromo and ω-carboxy groups for immobilization of biomolecules
    Guo, DJ
    Xiao, SJ
    Xia, B
    Shuai-Wei
    Pei, J
    Pan, Y
    You, XZ
    Gu, ZZ
    Lu, ZH
    [J]. JOURNAL OF PHYSICAL CHEMISTRY B, 2005, 109 (43) : 20620 - 20628
  • [10] Voltammetric studies of lead at calixarene modified screen-printed carbon electrodes and its trace determination in water by stripping voltammetry
    Honeychurch, KC
    Hart, JP
    Cowell, DC
    Arrigan, DWM
    [J]. SENSORS AND ACTUATORS B-CHEMICAL, 2001, 77 (03) : 642 - 652