Human-level blood cell counting on lens-free shadow images exploiting deep neural networks

被引:12
作者
Ahn, DaeHan [1 ]
Lee, JiYeong [1 ]
Moon, SangJun [2 ]
Park, Taejoon [1 ]
机构
[1] Hanyang Univ, Dept Robot Engn, 55 Hanyangdaehak Ro, Gyeonggi Do 15588, South Korea
[2] UNIST, 50 UNIST Gil, Ulsan 44919, South Korea
关键词
D O I
10.1039/c8an01056k
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
In point-of-care testing, in-line holographic microscopes paved the way for realizing portable cell counting systems at marginal cost. To maximize their accuracy, it is critically important to reliably count the number of cells even in noisy blood images overcoming various problems due to out-of-focus blurry cells and background brightness variations. However, previous studies could detect cells only on clean images while they failed to accurately distinguish blurry cells from background noises. To address this problem, we present a human-level blood cell counting system by synergistically integrating the methods of normalized cross-correlation (NCC) and a convolutional neural network (CNN). Our comprehensive performance evaluation demonstrates that the proposed system achieves the highest level of accuracy (96.7-98.4%) for any kinds of blood cells on a lens-free shadow image while others suffer from significant accuracy degradations (12.9-38.9%) when detecting blurry cells. Moreover, it outperforms others by up to 36.8% in accurately analyzing noisy blood images and is 24.0-40.8x faster, thus maximizing both accuracy and computational efficiency.
引用
收藏
页码:5380 / 5387
页数:8
相关论文
共 31 条
[1]   Optimization of a Cell Counting Algorithm for Mobile Point-of-Care Testing Platforms [J].
Ahn, DaeHan ;
Kim, Nam Sung ;
Moon, SangJun ;
Park, Taejoon ;
Son, Sang Hyuk .
SENSORS, 2014, 14 (08) :15244-15261
[2]  
Salazar DA, 2012, REV COLOMB ESTAD, V35, P223
[3]   Automatic segmentation of adherent biological cell boundaries and nuclei from brightfield microscopy images [J].
Ali, Rehan ;
Gooding, Mark ;
Szilagyi, Tuende ;
Vojnovic, Borivoj ;
Christlieb, Martin ;
Brady, Michael .
MACHINE VISION AND APPLICATIONS, 2012, 23 (04) :607-621
[4]   Point-of-care testing [J].
Anderson D.A. ;
Crowe S.M. ;
Garcia M. .
Current HIV/AIDS Reports, 2011, 8 (1) :31-37
[5]  
[Anonymous], ARXIV150500393V3CSCV
[6]  
[Anonymous], **DROPPED REF**
[7]  
[Anonymous], MANUAL CELL COUNTING
[8]  
[Anonymous], 1995, CANADIAN IMAGE PROCE
[9]  
[Anonymous], ARXIV12110336PHYSICS
[10]  
[Anonymous], 2016, PROC CVPR IEEE, DOI DOI 10.1109/CVPR.2016.262