Remote Vital Sign Monitoring With Reduced Random Body Swaying Motion Using Heartbeat Template and Wavelet Transform Based on Constellation Diagrams

被引:18
作者
Dai, Toan K. Vo [1 ]
Yu, Yao [2 ]
Theilmann, Paul [2 ]
Fathy, Aly E. [1 ]
Kilic, Ozlem [1 ]
机构
[1] Univ Tennessee, Knoxville, TN 37996 USA
[2] MaXentr Technol LLC, La Jolla, CA 92037 USA
来源
IEEE JOURNAL OF ELECTROMAGNETICS RF AND MICROWAVES IN MEDICINE AND BIOLOGY | 2022年 / 6卷 / 03期
关键词
Heart beat; Heterojunction bipolar transistors; Radar; Constellation diagram; Passband; Monitoring; Continuous wavelet transforms; Remote vital signs detection; millimeter wave (mmWave); random body motion (RBM); multiple-input multiple-output (MIMO); arctangent demodulation (AD); CWT with adapted wavelet; frequency modulated continuous wave (FMCW) radar; MOVEMENT CANCELLATION; RADAR; SYSTEM;
D O I
10.1109/JERM.2022.3140900
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
Remote vital signs monitoring using millimeter-wave (mmWave) sensors has gained lots of attention because of their contactless, portable advantages. However, their received signals are more sensitive to random body motions (RBM) which degrades the accuracy of heart rate (HR) detection. To overcome this challenge, multi-input multi-output (MIMO) configuration can be used to reduce RBM's impact as each channel has different points of view with respect to the subject under test (SUT). Here we propose the use of a Frequency Modulated Continuous Wave (FMCW) radar from Texas Instruments (TI) at 77 GHz to collect data from its 192-channel configuration. Since vital sign information extracted using Arctangent Demodulation (AD) could be corrupted by either RBM or respiratory harmonics, a method is needed to minimize such effects. Hence, we develop an algorithm where a Heartbeat Template (HBT) is extruded based on the Constellation Diagram that shows the Quadrature signals from the target's range profile. The HBT is then used to design an adapted-wavelet for Continuous Wavelet Transform (CWT) to magnify the heartbeat signals. Under circumstances where RBM overwhelms the heartbeat signal that the HBT cannot completely reduce its effects, a spectral-based HR selection method is also developed to estimate the HR. By employing the proposed methods, we have reduced mean-error ${\mu _e}$ of HR estimation significantly from 9 bpm to less than 2 bpm.
引用
收藏
页码:429 / 436
页数:8
相关论文
共 29 条
[1]  
Ahmad A, 2018, IEEE RAD CONF, P1450, DOI 10.1109/RADAR.2018.8378778
[2]   Remote Monitoring of Human Vital Signs Using mm-Wave FMCW Radar [J].
Alizadeh, Mostafa ;
Shaker, George ;
Martins De Almeida, Joao Carlos ;
Morita, Plinio Pelegrini ;
Safavi-Naeini, Safeddin .
IEEE ACCESS, 2019, 7 :54958-54968
[3]  
Banet M. J., 2008, U.S. Patent, Patent No. 0068614
[4]   Enhancement of Remote Vital Sign Monitoring Detection Accuracy Using Multiple-Input Multiple-Output 77 GHz FMCW Radar [J].
Dai, Toan K. Vo ;
Oleksak, Kellen ;
Kvelashvili, Tsotne ;
Foroughian, Farnaz ;
Bauder, Chandler ;
Theilmann, Paul ;
Fathy, Aly E. ;
Kilic, Ozlem .
IEEE JOURNAL OF ELECTROMAGNETICS RF AND MICROWAVES IN MEDICINE AND BIOLOGY, 2022, 6 (01) :111-122
[5]  
Dham V., 2020, SWRA553A TEX INSTR
[6]   Low-Cost Differential Front-End for Doppler Radar Vital Sign Monitoring [J].
Fletcher, Rich ;
Han, Jing .
2009 IEEE/MTT-S INTERNATIONAL MICROWAVE SYMPOSIUM, VOLS 1-3, 2009, :1325-1328
[7]  
Gao RX, 2011, WAVELETS: THEORY AND APPLICATIONS FOR MANUFACTURING, P205, DOI 10.1007/978-1-4419-1545-0_12
[8]  
Genc S, 2011, IEEE ENG MED BIO, P2216, DOI 10.1109/IEMBS.2011.6090419
[9]   Deep Neural Network based Body Movement Cancellation for Doppler Radar Vital Sign Detection [J].
Gu, Changzhan ;
Wang, Jian ;
Lien, Jaime .
2019 IEEE MTT-S INTERNATIONAL WIRELESS SYMPOSIUM (IWS 2019), 2019,
[10]   A Hybrid Radar-Camera Sensing System With Phase Compensation for Random Body Movement Cancellation in Doppler Vital Sign Detection [J].
Gu, Changzhan ;
Wang, Guochao ;
Li, Yiran ;
Inoue, Takao ;
Li, Changzhi .
IEEE TRANSACTIONS ON MICROWAVE THEORY AND TECHNIQUES, 2013, 61 (12) :4678-4688