Direct determination of total mercury in urine samples using flow injection catalytic cold vapor atomic absorption spectrometry (FI-CCV-AAS)

被引:15
作者
Sabouri, A. [1 ]
Nouroozi, S. [1 ]
机构
[1] Univ Zanjan, Dept Chem, Zanjan 3879145371, Iran
关键词
SOLID-PHASE EXTRACTION; INORGANIC MERCURY; TOTAL IRON; METHYLMERCURY; SPECIATION; METHYL; SYSTEM; BLOOD; WATER;
D O I
10.1039/c6ra16974k
中图分类号
O6 [化学];
学科分类号
0703 ;
摘要
A rapid flow injection catalytic cold vapor atomic absorption spectrometric (FI-CCV-AAS) method is described for determination of total mercury in urine samples. In this work, instead of preliminary oxidation or digestion steps, efficiency of vaporization of organic mercury was increased using Fe3+ as the catalyst directly in line in the flow injection protocol, therefore sample pretreatment was eliminated. Several physical and chemical variables in the flow injection system were studied and optimized in order to generate identical analytical signals for both inorganic and organic mercury. Due to the similarity of the resulting sensitivity, Hg2+ was used successfully as a primary standard for calibration. Limit of detection, coefficient of regression and linear dynamic range were obtained as 0.14 mu g L-1, 0.9997 and 0.50-35.0 mu g L-1, respectively. The use of flow injection system enabled fast analysis with a sample throughput of 108 h(-1). The application of the method to the quantification of total mercury in the two levels of urine reference material (SRM 3668) gave 107.7% and 97.3% recoveries for lower and elevated levels, respectively. The method successfully recovered spiked Hg2+ and methylmercury in 101 urine samples in the range of 93.4-104.5%.
引用
收藏
页码:80354 / 80360
页数:7
相关论文
共 32 条
[1]  
Aronsson A M, 1989, Biol Met, V2, P25, DOI 10.1007/BF01116197
[2]   METHYLMERCURY POISONING IN IRAQ - INTERUNIVERSITY REPORT [J].
BAKIR, F ;
DAMLUJI, SF ;
AMINZAKI, L ;
MURTADHA, M ;
KHALIDI, A ;
ALRAWI, NY ;
TIKRITI, S ;
DHAHIR, HI ;
CLARKSON, TW ;
SMITH, JC ;
DOHERTY, RA .
SCIENCE, 1973, 181 (4096) :230-241
[3]   Mercury determination by cold vapor atomic absorption spectrometry utilizing UV photoreduction [J].
Bendl, RF ;
Madden, JT ;
Regan, AL ;
Fitzgerald, N .
TALANTA, 2006, 68 (04) :1366-1370
[4]  
Blunden S., 1986, ORGANOMETALLIC COMPO
[5]  
Clesceri L. S., 1999, STANDARD METHODS EXA
[6]   AUTOMATED-DETERMINATION OF MERCURY IN URINE AND BLOOD BY THE MAGOS REAGENT AND COLD VAPOR ATOMIC-ABSORPTION SPECTROMETRY [J].
COYLE, P ;
HARTLEY, T .
ANALYTICAL CHEMISTRY, 1981, 53 (02) :354-356
[7]   Novel flow injection analysis methods for the determination of total iron in blood serum and water [J].
Elsuccary, S. A. A. ;
Salem, Alaa A. .
TALANTA, 2015, 131 :108-115
[8]   DETERMINATION OF MERCURY IN URINE BY FLOW-INJECTION COLD VAPOR ATOMIC-ABSORPTION SPECTROMETRY [J].
GUO, TZ ;
BAASNER, J .
ANALYTICA CHIMICA ACTA, 1993, 278 (01) :189-196
[9]  
HARRINGT.JM, 1974, LANCET, V1, P86
[10]   Determination of iron(II) and total iron in environmental water samples by flow injection analysis with column preconcentration of chelating resin functionalized with N-hydroxyethylethylenediamine ligands and chemiluminescence detection [J].
Hirata, S ;
Yoshihara, H ;
Aihara, M .
TALANTA, 1999, 49 (05) :1059-1067