An improved PID switching control strategy for type 1 diabetes

被引:146
作者
Marchetti, Gianni [1 ]
Barolo, Massimiliano [1 ]
Jovanovic, Lois [2 ]
Zisser, Howard [2 ]
Seborg, Dale E. [1 ]
机构
[1] Univ Padua, Dipartimento Principi & Impianti Ingn Chim, I-35131 Padua, Italy
[2] Sansum Diabet Res Fdn, Santa Barbara, CA 93105 USA
关键词
control set-point trajectory; glucose control; insulin sensitivity; PID controller; switching; type; 1; diabetes;
D O I
10.1109/TBME.2008.915665
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
In order for an "artificial pancreas" to become a reality for ambulatory use, a practical closed-loop control strategy must be developed and validated. In this paper, an improved PID control strategy for blood glucose control is proposed and critically evaluated in silico using a physiologic model of Hovorka et al. [1]. The key features of the proposed control strategy are: 1) a switching strategy for initiating PID control after a meal and insulin bolus; 2) a novel time-varying setpoint trajectory; 3) noise and derivative filters to reduce sensitivity to sensor noise; and 4) a practical controller tuning strategy. Simulation results demonstrate that proposed control strategy compares favorably to alternatives for realistic conditions that include meal challenges, incorrect carbohydrate meal estimates, changes in insulin sensitivity, and measurement noise.
引用
收藏
页码:857 / 865
页数:9
相关论文
共 22 条
[1]   The subcutaneous route to insulin-dependent diabetes therapy [J].
Bellazzi, R ;
Nucci, G ;
Cobelli, C .
IEEE ENGINEERING IN MEDICINE AND BIOLOGY MAGAZINE, 2001, 20 (01) :54-64
[2]  
Bequette B Wayne, 2005, Diabetes Technol Ther, V7, P28, DOI 10.1089/dia.2005.7.28
[3]  
Bergman RN, 1997, PENN CTR N, V7, P3
[4]   Expert PID control system for blood glucose control in critically Ill patients [J].
Chee, F ;
Fernando, TL ;
Savkin, AV ;
van Heeden, V .
IEEE TRANSACTIONS ON INFORMATION TECHNOLOGY IN BIOMEDICINE, 2003, 7 (04) :419-425
[5]   Evaluating the clinical accuracy of two continuous glucose sensors using continuous glucose-error grid analysis [J].
Clarke, WL ;
Anderson, S ;
Farhy, L ;
Breton, M ;
Gonder-Frederick, L ;
Cox, D ;
Kovatchev, B .
DIABETES CARE, 2005, 28 (10) :2412-2417
[6]  
COBELLI C, 1998, DIABETES NUTR METAB, V11, P78
[7]   Derivative weighted active insulin control algorithms and intensive care unit trials [J].
Doran, CV ;
Chase, JG ;
Shaw, GM ;
Moorhead, KT ;
Hudson, NH .
CONTROL ENGINEERING PRACTICE, 2005, 13 (09) :1129-1137
[8]  
FINAN DA, 2006, P INT S ADV CONTR CH, P503
[9]   The importance of tight glycemic control [J].
Gerich, JE .
AMERICAN JOURNAL OF MEDICINE, 2005, 118 :7S-11S
[10]   Management of diabetes using adaptive control [J].
Hovorka, R .
INTERNATIONAL JOURNAL OF ADAPTIVE CONTROL AND SIGNAL PROCESSING, 2005, 19 (05) :309-325